@ -7,14 +7,15 @@ pumps. Controller can be easily used for newly designed heat pumps (HPs), includ
## Specs
- 12V 0.5A DC power supply,
- 230V output
- 230V output,
- up to 12 T sensors, -55..+125 °C range,
- 4 relays: Compressor, Hot CP or Air Fan, Cold CP or Air Fan, Crankcase Heater
- 2 inputs: Hot and cold side refrigerant over/under pressure NC sensors
- 6 pin EEV connection: 4 * coils + 2 * 12V
- control via remote display or local Serial (UART 5V)
- automatically turns on/of system when heating required
- takes care of system components, built-in protections: cold start, overheat, short-term power loss, power overload, ground loop freeze and compressor protection against liquid.
- 4 relays: Compressor, Hot CP or Air Fan, Cold CP or Air Fan, Crankcase Heater,
- 2 inputs: Hot and cold side refrigerant over/under pressure NC sensors,
- 6 pin EEV connection: 4 * coils + 2 * 12V,
- LED indication,
- control via remote display or local Serial (UART 5V),
- automatically turns on/of system when heating required,
- built-in protections: cold start, overheat, short-term power loss, power overload, ground loop freeze and compressor protection against liquid.
<br><br>
## Refrigeration schemes supported