@ -81,7 +81,7 @@ Phases (1st wire in electrical cables):
- and connect the second "phase" terminal to the AC input of the 12V power supply, - and connect the second "phase" terminal to the AC input of the 12V power supply,
- connect the "Compressor" relay output to the Compressor input, - connect the "Compressor" relay output to the Compressor input,
- connect the "Hot CP" relay output to the Hot Circulation Pump input (or to the fan power input of the indoor unit if you are using an air system), - connect the "Hot CP" relay output to the Hot Circulation Pump input (or to the fan power input of the indoor unit if you are using an air system),
- connect the "Cold CP" relay output to the Cold Circulation Pump input (or to the fan power input of the outdoor unit air fan), - connect the "Cold CP" relay output to the Cold Circulation Pump input (or to the fan power input of the outdoor unit),
- when using a compressor heater: connect the "Crankcase heater" relay output to the heater cable (highly recommended for outdoor installation and year-round use). - when using a compressor heater: connect the "Crankcase heater" relay output to the heater cable (highly recommended for outdoor installation and year-round use).
Neutral (2nd cable in electrical cables), Neutral (2nd cable in electrical cables),
- connect all the second wires of power cords to the "neutral" terminals on the board. - connect all the second wires of power cords to the "neutral" terminals on the board.