@ -81,7 +81,7 @@ Phases (1st wire in electrical cables):
|
||||||
- and connect the second "phase" terminal to the AC input of the 12V power supply,
|
- and connect the second "phase" terminal to the AC input of the 12V power supply,
|
||||||
- connect the "Compressor" relay output to the Compressor input,
|
- connect the "Compressor" relay output to the Compressor input,
|
||||||
- connect the "Hot CP" relay output to the Hot Circulation Pump input (or to the fan power input of the indoor unit if you are using an air system),
|
- connect the "Hot CP" relay output to the Hot Circulation Pump input (or to the fan power input of the indoor unit if you are using an air system),
|
||||||
- connect the "Cold CP" relay output to the Cold Circulation Pump input (or to the fan power input of the outdoor unit air fan),
|
- connect the "Cold CP" relay output to the Cold Circulation Pump input (or to the fan power input of the outdoor unit),
|
||||||
- when using a compressor heater: connect the "Crankcase heater" relay output to the heater cable (highly recommended for outdoor installation and year-round use).
|
- when using a compressor heater: connect the "Crankcase heater" relay output to the heater cable (highly recommended for outdoor installation and year-round use).
|
||||||
Neutral (2nd cable in electrical cables),
|
Neutral (2nd cable in electrical cables),
|
||||||
- connect all the second wires of power cords to the "neutral" terminals on the board.
|
- connect all the second wires of power cords to the "neutral" terminals on the board.
|
||||||
|
|