diff --git a/README.md b/README.md index 9dd3464..9a31c4c 100644 --- a/README.md +++ b/README.md @@ -134,9 +134,8 @@ qwer | ------------- | ------------- | | **Normal_stop** | Normal stop, i.e. setpoint sensor temperature > setpoint, so no need to heat anymore | | **P.WtMax:_WATTS_** | Protective stop, overcurrent, double check your system, **MAX_WATTS** and **POWERON_HIGHTIME** options | -| **E.Tci, E.Tco, E.Tbe,
E.Tae, E.Ts1, E.Ts2,
E.Tcrc, E.Treg, E.Tac,
E.Tbc, E.Tho, E.Thi** | Sensor lost, check wiring. Refer to "T sensors abbreviations"| -| **E.PresCold** | Cold side pressure too low, check refrigerant charge and pressure sensors | -| **E.PresHot** | Hot side pressure too high, check refrigerant charge and pressure sensors | +| **P.W.wattMIN** | c_wattage_max/5 , see **MAX_WATTS** option | +| **P.W.TcrcMIN** | see **T_WORKINGOK_CRANKCASE_MIN** option | | **P.Tho** | Protective stop, check system, see **T_HOT_MAX** option | | **P.Thi** | Protective stop, check system, see **T_HOT_MAX** option | | **P.Tcrc** | Protective stop, check system, see **T_CRANKCASE_MAX** option | @@ -145,38 +144,43 @@ qwer | **P.Tbc** | Protective stop, check system, see **T_BEFORE_CONDENSER_MAX** option | | **P.Tci** | Protective stop, check system, see **T_COLD_MIN** option | | **P.Tco** | Protective stop, check system, see **T_COLD_MIN** option | -| **P.W.TcrcMIN** | see **T_WORKINGOK_CRANKCASE_MIN** option | -| **P.W.wattMIN** | c_wattage_max/5 , see **MAX_WATTS** option | +| **E.Tci, E.Tco, E.Tbe,
E.Tae, E.Ts1, E.Ts2,
E.Tcrc, E.Treg, E.Tac,
E.Tbc, E.Tho, E.Thi** | Sensor lost, check wiring. Refer to "T sensors abbreviations"| +| **E.PresCold** | Cold side pressure too low, check refrigerant charge and pressure sensors | +| **E.PresHot** | Hot side pressure too high, check refrigerant charge and pressure sensors | **LastStartMessage messages. What event system is waiting for starting work and some additional events**

-**StCntd:_seconds_** startup countdown, short-term power loss protection
-**HP_Started** normal start
-**HWP_OFF** setpoint sensor temperature > setpoint, so hot side pump powered off and going to power saving mode, see **HOTCIRCLE_STOP_AFTER**
-**HWP_ON_by_ev** hot side pump started after power saving, see **HOTCIRCLE_START_EVERY** option
-**#CWPpStart** coldside pump started, preparing system to start compressor
-**#HotPrp:_seconds_** hot side pump is on, waiting for T stabilisation countdown see **HOTCIRCLE_CHECK_PREPARE** option
-**#HotSlp:_seconds_** sleepeng, last cycle temperature was > setpoint, waiting for next startup, see **HOTCIRCLE_START_EVERY** option
-**#HPSlp:_seconds_**" + String( (mincycle_poweroff -(unsigned long)(millis_now - millis_last_heatpump_on))/1000 );
-**#CWPp:_seconds_** coldside pumping, preparing countdown**COLDCIRCLE_PREPARE** option
-**#Tho>Max** , see **T_HOT_MAX** option
-**#Thi>Max** , see **T_HOT_MAX** option
-**#CaseCold** , see **T_CRANKCASE_MIN** option
-**#CaseHot** , see **T_CRANKCASE_MAX** option
-**#Thi>Setp.** hot in temperature > setpoint, so no reason to start
-**#Ts1>Setp.** s1 temperature > setpoint, so no reason to start, see SETPOINT_TS1 option to switch betwees Thi and Ts1 as setpoint sensor
-**#Tae -**#Tbe -**#Tbc>Max** Before Condenser temperature is too high, check system, see **T_BEFORE_CONDENSER_MAX** option
-**#Tci -**#Tco -**CWP_ON_CoMin** coldside pump started, cold side temperature is too low, so preventing cold loop freeze, see **T_COLD_MIN** option
+| Message | description | +| ------------- | ------------- | +| **StCntd:_seconds_** | startup countdown, short-term power loss protection | +| **HP_Started** | normal start | +| **HWP_OFF** | setpoint sensor temperature > setpoint, so hot side pump powered off and going to power saving mode, see **HOTCIRCLE_STOP_AFTER** | +| **HWP_ON_by_ev** | hot side pump started after power saving, see **HOTCIRCLE_START_EVERY** option | +| **#CWPpStart** | coldside pump started, preparing system to start compressor | +| **#HotPrp:_seconds_** | hot side pump is on, waiting for T stabilisation countdown see **HOTCIRCLE_CHECK_PREPARE** option | +| **#HotSlp:_seconds_** | sleepeng, last cycle temperature was > setpoint, waiting for next startup, see **HOTCIRCLE_START_EVERY** option | +| **#HPSlp:_seconds_**" | + String( (mincycle_poweroff -(unsigned long)(millis_now - millis_last_heatpump_on))/1000 ); | +| **#CWPp:_seconds_** | coldside pumping, preparing countdown**COLDCIRCLE_PREPARE** option | +| **#Tho>Max** | , see **T_HOT_MAX** option | +| **#Thi>Max** | , see **T_HOT_MAX** option | +| **#CaseCold** | , see **T_CRANKCASE_MIN** option | +| **#CaseHot** | , see **T_CRANKCASE_MAX** option | +| **#Thi>Setp.** | hot in temperature > setpoint, so no reason to start | +| **#Ts1>Setp.** | Ts1 temperature > setpoint, so no reason to start, see SETPOINT_TS1 option to switch betwees Thi and Ts1 as setpoint sensor | +| **#TaeMax** | Before Condenser temperature is too high, check system, see **T_BEFORE_CONDENSER_MAX** option | +| **#Tci -**OK:E.T.Sens.** Sensor restored
-**OK:Pr.Cold** Cold side pressure restored
-**OK:Pr.Hot** Hot side pressure restored
-**HWP_ON** hot side pump powered on
-**Err:_errorcode_** Error code: 1 = temperature sensor error, 2 = Hot side pressure too high 3 = cold side pressure too low
+**Additional messages**

+| Message | description | +| ------------- | ------------- | +| **OK:E.T.Sens.** | Sensor restored
+| **OK:Pr.Cold** | Cold side pressure restored
+| **OK:Pr.Hot** | Hot side pressure restored
+| **HWP_ON** | hot side pump powered on
+| **Err:_errorcode_** | Error code: 1 = temperature sensor error, 2 = Hot side pressure too high 3 = cold side pressure too low
## Firmware options and fine tunings