mirror of
https://github.com/openhp/HeatPumpController.git
synced 2024-11-18 12:33:59 +00:00
Update README.md
This commit is contained in:
parent
45c0cbe974
commit
32cec174bd
1 changed files with 8 additions and 2 deletions
10
README.md
10
README.md
|
@ -70,7 +70,13 @@ To check EEV connection, you can use a stepper motor as shown in the video. If
|
||||||
To check temperature sensors connectors crimp one array of sensors. Plug it to all sensors connectors one-by-one and check results in a serial console.<br>
|
To check temperature sensors connectors crimp one array of sensors. Plug it to all sensors connectors one-by-one and check results in a serial console.<br>
|
||||||
{-Photo: PCB with connected arrays of sensors (I have enough sensors, so all 3 arrays are connected except Ts2 and Treg) -}<br>
|
{-Photo: PCB with connected arrays of sensors (I have enough sensors, so all 3 arrays are connected except Ts2 and Treg) -}<br>
|
||||||
{-Screenshot: serial console with temperature readings: -}<br>
|
{-Screenshot: serial console with temperature readings: -}<br>
|
||||||
After tests completed comment 3 self-test defines and re-upload firmware. Your controller is ready to a first start (after wiring).<br><br>
|
After tests completed comment 3 self-test defines.<br>
|
||||||
|
Choose what so you wand to heat and uncomment one of those options:
|
||||||
|
```c
|
||||||
|
#define SETPOINT_THI //"warm floor" scheme: "hot in" (Thi) temperature used as setpoint
|
||||||
|
//#define SETPOINT_TS1 //"swimming pool" or "water tank heater" scheme: "sensor 1" (Ts1) is used as setpoint and located somewhere in a water tank
|
||||||
|
```
|
||||||
|
Re-upload firmware. Your controller is ready to a first start (after wiring). Probably you'll never need to change other options.<br><br>
|
||||||
|
|
||||||
## Wiring (permanent controller installation).
|
## Wiring (permanent controller installation).
|
||||||
Here are no instructions for choosing the right placement for permanent installation of the controller. It depends. You're building your system, and you know much better "where" and "how".<br>
|
Here are no instructions for choosing the right placement for permanent installation of the controller. It depends. You're building your system, and you know much better "where" and "how".<br>
|
||||||
|
@ -316,7 +322,7 @@ System type, comment both if HP with EEV
|
||||||
//#define NO_EEV //capillary tube or TXV, EEV not used
|
//#define NO_EEV //capillary tube or TXV, EEV not used
|
||||||
```
|
```
|
||||||
|
|
||||||
What sensor is used to check setpoint, uncomment one of those options
|
Sensor used to check setpoint, uncomment one of those options
|
||||||
```c
|
```c
|
||||||
#define SETPOINT_THI //"warm floor" scheme: "hot in" (Thi) temperature used as setpoint
|
#define SETPOINT_THI //"warm floor" scheme: "hot in" (Thi) temperature used as setpoint
|
||||||
//#define SETPOINT_TS1 //"swimming pool" or "water tank heater" scheme: "sensor 1" (Ts1) is used as setpoint and located somewhere in a water tank
|
//#define SETPOINT_TS1 //"swimming pool" or "water tank heater" scheme: "sensor 1" (Ts1) is used as setpoint and located somewhere in a water tank
|
||||||
|
|