mirror of
https://github.com/openhp/HeatPumpController.git
synced 2024-11-08 12:25:43 +00:00
Update README.md
This commit is contained in:
parent
ca8ae2f82e
commit
38546d3a45
1 changed files with 8 additions and 8 deletions
16
README.md
16
README.md
|
@ -98,17 +98,17 @@ Phases (1st wire in electrical cables):
|
|||
<img src="./m_c_wiring_12v.jpg" width="600"><br>
|
||||
|
||||
Crimp and plug low-voltage connectors:
|
||||
- crimp SCT013 sensor wires (the only one low-voltage device in this circuit with interchangeable wires), connect and install it on the inlet phase wire,
|
||||
<img src="./m_c_wiring_current_sensor.jpg" width="600">
|
||||
- crimp SCT013 sensor wires (the only one low-voltage device in this circuit with interchangeable wires), connect and install it on the inlet phase wire,<br>
|
||||
<img src="./m_c_wiring_current_sensor.jpg" width="600"><br>
|
||||
- crimp RS485 to the Remote Display, using a wire of desired length (note that A is connected to A, B to B and GND to GND),
|
||||
- crimp 12V and GND secondary terminals to the remote display,
|
||||
<img src="./m_c_wiring_display.jpg" width="600">
|
||||
- connect EEV to EEV terminal,
|
||||
<img src="./m_c_wiring_EEV.jpg" width="600">
|
||||
- crimp 12V and GND secondary terminals to the remote display,<br>
|
||||
<img src="./m_c_wiring_display.jpg" width="600"><br>
|
||||
- connect EEV to EEV terminal,<br>
|
||||
<img src="./m_c_wiring_EEV.jpg" width="600"><br>
|
||||
- install all T sensors on pipes, insulate tubes,
|
||||
- crimp T sensors arrays, you can crimp all four GND wires at every array to one GND connector pin or make 1-to-4 connection somewhere closer to sensors location (same for +5V wires),
|
||||
- insert T sensors arrays to appropriate terminals (if you do not need to control over all temperatures, disable and do not install unnecessary sensors),
|
||||
<img src="./m_c_wiring_t_sensors.jpg" width="600">
|
||||
- insert T sensors arrays to appropriate terminals (if you do not need to control over all temperatures, disable and do not install unnecessary sensors),<br>
|
||||
<img src="./m_c_wiring_t_sensors.jpg" width="600"><br>
|
||||
- crimp and plug pressure sensors outputs: crimp 1st wires together to **12V** (right output of the terminal), 2nd cold side wire to the **Pco** (left), 2nd hot side wire to the **Phi** (middle); use the dummy if no pressure sensors used in your system.
|
||||
<img src="./m_c_wiring_pressure.jpg" width="600"><br>
|
||||
<img src="./m_c_wiring_pressure_dummy.jpg" width="600"><br>
|
||||
|
|
Loading…
Reference in a new issue