@@ -375,8 +375,8 @@ Watts, cycles times (milliseconds)
#define HOTCIRCLE_STOP_AFTER (HOTCIRCLE_CHECK_PREPARE + COLDCIRCLE_PREPARE + 30000) //...and then stop after few minutes of circulating, if temperature is high and no need to start compressor; value must be check_prepare + coldcircle_prepare + 30 seconds (or more)
```
-EEV options
-If you are using a capillary tube or TXV: simply skip next section
+EEV options.
+If you are using a capillary tube or TXV: simply skip next section.
Depending on how many milliseconds allocated per step, the speed of automatic tuning will change.
Remember that your refrigeration system reaction on every step is not immediate. The system reacts after a few minutes, sometimes after tens of minutes.
```c
@@ -400,17 +400,17 @@ Remember that your refrigeration system reaction on every step is not immediate.
//temperatures
#define EEV_PRECISE_START 7.0 //(8.6 tube evaporator) precise tuning threshold: make slower pulses if (real_diff-target_diff) less than this value. Used for fine auto-tuning
-#define EEV_EMERG_DIFF 1.7 //(2.5 tube evaporator) liquid at suction threshold: if dangerous condition occured: real_diff =< (target_diff - EEV_EMERG_DIFF) then EEV will be closed to min. work position //Ex: EEV_EMERG_DIFF = 2.0, target diff 5.0, if real_diff =< (5.0 - 2.0) then EEV will be closed to EEV_MINWORKPOS
-#define EEV_HYSTERESIS 0.5 //(0.6 tube evaporator) hysteresis, to stop fine tuning: must be less than EEV_PRECISE_START, ex: target difference = 4.0, hysteresis = 0.3, no EEV pulses will be done while real difference in range 4.0..4.3
-#define EEV_TARGET_TEMP_DIFF 3.6 //(3.6 tube evaporator) target difference between Before Evaporator and After Evaporator, the head of whole algorithm
+#define EEV_EMERG_DIFF 1.7 //(2.5 tube evaporator) liquid at suction threshold: if dangerous condition occurred, real_diff =< (target_diff - EEV_EMERG_DIFF) then EEV will be closed to min. work position //Ex: EEV_EMERG_DIFF = 2.0, target diff 5.0, if real_diff =< (5.0 - 2.0) then EEV will be closed to EEV_MINWORKPOS
+#define EEV_HYSTERESIS 0.5 //(0.6 tube evaporator) hysteresis, to stop fine-tuning: must be less than EEV_PRECISE_START, ex: target difference = 4.0, hysteresis = 0.3, no EEV pulses will be done while real difference in range 4.0..4.3
+#define EEV_TARGET_TEMP_DIFF 3.6 //(3.6 tube evaporator) target difference between Before Evaporator and After Evaporator, the head of the whole algorithm
//additional options
#define EEV_REOPENLAST 1 //1 = reopen to last position on compressor start, useful for ordinary schemes with everyday working cycles, 0 = not
#define EEV_REOPENMINTIME 40000 //after system start: min. delay between "min. work pos." (must be > 0 in this case and > waiting position) set and reopening start
-//#define EEV_MANUAL //comment to disable, manual set of EEV position via console; warning: this option will stop all EEV auto-activities, including zero position find procedure; so this option not recommended: switching auto/manual mode from console after startup is a better way
+//#define EEV_MANUAL //comment to disable, manual set of EEV position via a console; warning: this option will stop all EEV auto-activities, including zero position find procedure; so this option not recommended: switch auto/manual mode from a console
-//do not use next option untill you're not really need it
-//#define EEV_DEBUG //debug, usefull during system fine tuning, works both with local serial and RS485_HUMAN
+//do not use next option if you're not sure what are you doing
+//#define EEV_DEBUG //debug, useful during system fine-tuning, works both with local serial and RS485_HUMAN
```