@ -302,19 +302,19 @@ Communication protocol with an external world. Choose one.
|
|||
```c
|
||||
//#define RS485_JSON 1 //JSON, external systems integration
|
||||
//#define RS485_HUMAN 2 //RS485 is used in the same way as the local console, warning: Use only if 2 devices (server and this controller) connected to the same RS485 line
|
||||
#define RS485_MODBUS 3 //default, MODBUS via RS485, connection to the display (both sensor or 1602, see https://gitlab.com/valden/) or connection to any other MODBUS application or device
|
||||
#define RS485_MODBUS 3 //default, MODBUS via RS485, connection to the display (both sensor or 1602, see https://GitHub.com/OpenHP/Display/) or connection to any other MODBUS application or device
|
||||
```
|
||||
|
||||
System type, comment both if HP with EEV
|
||||
```c
|
||||
//#define EEV_ONLY //Valden controller as EEV controller: NO target T sensor. No relays. Oly EEV. Sensors required: Tae, Tbe, current sensor. Additional T sensors can be used but not required.
|
||||
//#define NO_EEV //capillary tube or TXV, EEV not used
|
||||
//#define EEV_ONLY //Valden controller as EEV controller: NO target T sensor. No relays. Oly EEV. Sensors required: Tae, Tbe, current sensor. Additional T sensors can be used but not required.
|
||||
//#define NO_EEV //capillary tube or TXV, EEV not used
|
||||
```
|
||||
|
||||
Which sensor is used to check setpoint, uncomment one of options
|
||||
What sensor is used to check setpoint, uncomment one of those options
|
||||
```c
|
||||
#define SETPOINT_THI //"warm floor" scheme: "hot in" (Thi) temperature used as setpoint
|
||||
//#define SETPOINT_TS1 //"swimming pool" or "water tank heater" scheme: "sensor 1" (Ts1) is used as setpoint and located somewhere in water tank
|
||||
#define SETPOINT_THI //"warm floor" scheme: "hot in" (Thi) temperature used as setpoint
|
||||
//#define SETPOINT_TS1 //"swimming pool" or "water tank heater" scheme: "sensor 1" (Ts1) is used as setpoint and located somewhere in a water tank
|
||||
```
|
||||
|
||||