Update README.md

This commit is contained in:
openhp 2021-03-21 21:47:19 +00:00 committed by GitHub
parent ba69c7fcf4
commit 6a08b0b8a7
No known key found for this signature in database
GPG key ID: 4AEE18F83AFDEB23

View file

@ -9,7 +9,7 @@ pumps. Controller can be easily used for newly designed heat pumps (HPs), includ
- 12V 0.5A DC power supply,
- 230V output
- up to 12 T sensors, -55..+125 °C range,
- 4 relays (<sub>Compressor, Hot CP or Air Fan, Cold CP or Air Fan, Crankcase Heater</sub>)
- 4 relays (<sub><sup>Compressor, Hot CP or Air Fan, Cold CP or Air Fan, Crankcase Heater</sup></sub>)
- 2 inputs (<sub>Hot and cold side refrigerant over/under pressure NC sensors</sub>)
- 6 pin EEV connection (4 * coils + 2 * 12V)
- control via remote display or local Serial(UART 5V)