@ -131,33 +131,6 @@ qwer
{-desc 2-}
link
## T sensors abbreviations
Abbreviations used in the documentation and firmware <br><br>
Main sensors:
| Abbr. | Full name |
| ----- | -------------------- |
| Tae | after evaporator |
| Tbe | before evaporator |
| Tci | cold side "input" |
| Tco | cold side "output" |
| Tbc | before condenser |
| Tac | after condenser |
| Thi | hot side "input" |
| Tho | hot side "output" |
| Tcrc | crankcase (compressor itself)|
Additional sensor used in "swiming pool heater" or "water tank heater" schemes:
| Abbr. | Full name |
| ----- | -------------------- |
| Ts1 | additional sensor1 |
Additional sensors, disabled and not used by default:
| Abbr. | Full name |
| ----- | -------------------- |
| Treg | regenerator temperature|
| Ts2 | additional sensor2 |
## Hints
For more information about Heat Pumps look at [Wikipedia about HP](https://en.wikipedia.org/wiki/Heat_pump).<br>
If you are interested in questions like "how refrigeration systems works" read Patrick Kotzaoglanian books.<br>
@ -180,6 +153,33 @@ This product is distributed in the hope that it will be useful, but WITHOUT ANY
<br>
gonzho АТ web.de (c) 2018-2021<br>
## T sensors abbreviations
Abbreviations used in the documentation and firmware <br><br>
Main sensors:
| Abbr. | Full name |
| ----- | -------------------- |
| Tae | after evaporator |
| Tbe | before evaporator |
| Tci | cold side "input" |
| Tco | cold side "output" |
| Tbc | before condenser |
| Tac | after condenser |
| Thi | hot side "input" |
| Tho | hot side "output" |
| Tcrc | crankcase (compressor itself)|
Additional sensor used in "swiming pool heater" or "water tank heater" schemes, check **SETPOINT_TS1** option:
| Abbr. | Full name |
| ----- | -------------------- |
| Ts1 | additional sensor1 |
Additional sensors, disabled and not used by default:
| Abbr. | Full name |
| ----- | -------------------- |
| Treg | regenerator temperature|
| Ts2 | additional sensor2 |
## Diagnostic and status messages
**LastStopCause messages. Why system was stopped**
| Message | description |