@ -3,14 +3,14 @@
pumps. Controller can be easily used for newly designed heat pumps (HPs), including series, as repair controller or as control system for experiments with refrigeration equipment.</b> pumps. Controller can be easily used for newly designed heat pumps (HPs), including series, as repair controller or as control system for experiments with refrigeration equipment.</b>
<br><br> <br><br>
<p style='color:red'>GENERATE TOC HERE</p> !!!GENERATE TOC HERE!!!
## Specs ## Specs
- 12V 0.5A DC power supply, - 12V 0.5A DC power supply,
- 230V output - 230V output
- up to 12 T sensors, -55..+125 °C range, - up to 12 T sensors, -55..+125 °C range,
- 4 relays (Compressor, Hot CP or Air Fan, Cold CP or Air Fan, Crankcase Heater) - 4 relays (<sub>Compressor, Hot CP or Air Fan, Cold CP or Air Fan, Crankcase Heater</sub>)
- 2 inputs (Hot and cold side refrigerant over/under pressure NC sensors) - 2 inputs (<sub>Hot and cold side refrigerant over/under pressure NC sensors</sub>)
- 6 pin EEV connection (4 * coils + 2 * 12V) - 6 pin EEV connection (4 * coils + 2 * 12V)
- control via remote display or local Serial(UART 5V) - control via remote display or local Serial(UART 5V)
- automatically turns on/of system when heating required - automatically turns on/of system when heating required