@ -3,14 +3,14 @@
|
||||||
pumps. Controller can be easily used for newly designed heat pumps (HPs), including series, as repair controller or as control system for experiments with refrigeration equipment.</b>
|
pumps. Controller can be easily used for newly designed heat pumps (HPs), including series, as repair controller or as control system for experiments with refrigeration equipment.</b>
|
||||||
<br><br>
|
<br><br>
|
||||||
|
|
||||||
<p style='color:red'>GENERATE TOC HERE</p>
|
!!!GENERATE TOC HERE!!!
|
||||||
|
|
||||||
## Specs
|
## Specs
|
||||||
- 12V 0.5A DC power supply,
|
- 12V 0.5A DC power supply,
|
||||||
- 230V output
|
- 230V output
|
||||||
- up to 12 T sensors, -55..+125 °C range,
|
- up to 12 T sensors, -55..+125 °C range,
|
||||||
- 4 relays (Compressor, Hot CP or Air Fan, Cold CP or Air Fan, Crankcase Heater)
|
- 4 relays (<sub>Compressor, Hot CP or Air Fan, Cold CP or Air Fan, Crankcase Heater</sub>)
|
||||||
- 2 inputs (Hot and cold side refrigerant over/under pressure NC sensors)
|
- 2 inputs (<sub>Hot and cold side refrigerant over/under pressure NC sensors</sub>)
|
||||||
- 6 pin EEV connection (4 * coils + 2 * 12V)
|
- 6 pin EEV connection (4 * coils + 2 * 12V)
|
||||||
- control via remote display or local Serial(UART 5V)
|
- control via remote display or local Serial(UART 5V)
|
||||||
- automatically turns on/of system when heating required
|
- automatically turns on/of system when heating required
|
||||||
|
|