mirror of
https://github.com/openhp/HeatPumpController.git
synced 2024-11-18 12:33:59 +00:00
Update README.md
This commit is contained in:
parent
ffd159cc57
commit
ba69c7fcf4
1 changed files with 3 additions and 3 deletions
|
@ -3,14 +3,14 @@
|
|||
pumps. Controller can be easily used for newly designed heat pumps (HPs), including series, as repair controller or as control system for experiments with refrigeration equipment.</b>
|
||||
<br><br>
|
||||
|
||||
<p style='color:red'>GENERATE TOC HERE</p>
|
||||
!!!GENERATE TOC HERE!!!
|
||||
|
||||
## Specs
|
||||
- 12V 0.5A DC power supply,
|
||||
- 230V output
|
||||
- up to 12 T sensors, -55..+125 °C range,
|
||||
- 4 relays (Compressor, Hot CP or Air Fan, Cold CP or Air Fan, Crankcase Heater)
|
||||
- 2 inputs (Hot and cold side refrigerant over/under pressure NC sensors)
|
||||
- 4 relays (<sub>Compressor, Hot CP or Air Fan, Cold CP or Air Fan, Crankcase Heater</sub>)
|
||||
- 2 inputs (<sub>Hot and cold side refrigerant over/under pressure NC sensors</sub>)
|
||||
- 6 pin EEV connection (4 * coils + 2 * 12V)
|
||||
- control via remote display or local Serial(UART 5V)
|
||||
- automatically turns on/of system when heating required
|
||||
|
|
Loading…
Reference in a new issue