**#HotSlp:_seconds_** sleepeng, last cycle temperature was > setpoint, waiting for next startup, see **HOTCIRCLE_START_EVERY** option<br>
|
||||
**#HPSlp:_seconds_**" + String( (mincycle_poweroff -(unsigned long)(millis_now - millis_last_heatpump_on))/1000 );<br>
|
||||
|
||||
**#Tho>Max**<br>
|
||||
**#Thi>Max**<br>
|
||||
**#CaseCold**<br>
|
||||
**#CaseHot**<br>
|
||||
**#Thi>Setp.**<br>
|
||||
**#Ts1>Setp.**<br>
|
||||
**#Tae<RefMin**<br>
|
||||
**#Tbe<RefMin**<br>
|
||||
**#Tbc>Max**<br>
|
||||
**#Tci<ColdMin**<br>
|
||||
**#Tco<ColdMin**<br>
|
||||
**#Tho>Max** T_HOT_MAX <br>
|
||||
**#Thi>Max** T_HOT_MAX <br>
|
||||
**#CaseCold** T_CRANKCASE_MIN <br>
|
||||
**#CaseHot** T_CRANKCASE_MAX <br>
|
||||
**#Thi>Setp.** hot in temperature > setpoint, so no reason to start<br>
|
||||
**#Ts1>Setp.** s1 temperature > setpoint, so no reason to start, see SETPOINT_TS1 option to switch betwees Thi and Ts1 as setpoint sensor <br>
|
||||
**#Tae<RefMin** After Evaporator temperature is too low, check system, see **T_COLDREF_MIN** option<br>
|
||||
**#Tbe<RefMin** Before Evaporator temperature is too low, check system, see **T_COLDREF_MIN** option<br>
|
||||
**#Tbc>Max** Before Condenser temperature is too high, check system, see **T_BEFORE_CONDENSER_MAX** option<br>
|
||||
**#Tci<ColdMin** Cold In temperature is too low, see **T_COLD_MIN** option <br>
|
||||
**#Tco<ColdMin** Cold In temperature is too high, see **T_COLD_MIN** option <br>
|
||||
**#CWPpStart** coldside pump started, preparing system to start compressor<br>
|
||||
**#CWPp:_seconds_** coldside pumping, preparing countdown**COLDCIRCLE_PREPARE** option<br>
|
||||
**HP_Started** normal start<br>
|
||||
|
||||
**#CWPpStart** coldside start, preparing system to start compressor<br>
|
||||
**#CWPp:"** + String( (COLDCIRCLE_PREPARE <br>
|
||||
**HP_Started**<br>
|
||||
**Normal_stop** normal stop, i.e. setpoint sensor temperature > setpoint, so no need to heat anymore<br>
|
||||
|
||||
**Normal_stop**<br>
|
||||
|
||||
**HWP_ON**<br>
|
||||
**HWP_ON_by_ev** hot side pump started after power saving, see **HOTCIRCLE_START_EVERY** option <br>
|
||||
**HWP_OFF** setpoint sensor temperature > setpoint, so hot side pump powered off and going to power saving mode, see **HOTCIRCLE_STOP_AFTER** <br>
|
||||
|
||||
((heatpump_state == 1) && (hotside_circle_state == 0) ) || ((_1st_start_sleeped == 0 )
|
||||
|
||||
(millis_now - millis_last_hotWP_on) > HOTCIRCLE_START_EVERY) ) { //process START_EVERY for hot side
|
||||
millis_last_hotWP_off = millis_now;
|
||||
hotside_circle_state = 1;
|
||||
//PrintSS(F("HWP ON by startevery"));
|
||||
lastStartMsgTxt = F("HWP_ON_by_ev");
|
||||
|
||||
deffered_stop_hotcircle) || millis_last_heatpump_on == 0) { //deffered stop aftret heat pump stop and correct processing of 1st start, 1st_start sleeped flag not used - there's another logic
|
||||
/*
|
||||
//useful for tank heater with Ts1 as setpont control and large intermediate water reservoir
|
||||
if ( (ThoE == 1 && Tho < (Ts1 + cT_hotcircle_delta_min)) ||
|
||||
(ThiE == 1 && Thi < (Ts1 + cT_hotcircle_delta_min)) ) {
|
||||
PrintSS(F("Hot CP OFF 1"));
|
||||
millis_last_hotWP_on = millis_now;
|
||||
hotside_circle_state = 0;
|
||||
} else {
|
||||
PrintSS(F("Hot CP OFF 2"));
|
||||
millis_last_hotWP_on = millis_now;
|
||||
hotside_circle_state = 0;
|
||||
}
|
||||
*/
|
||||
if ( (unsigned long)(millis_now - millis_last_hotWP_off) > HOTCIRCLE_STOP_AFTER) { //and START_EVERY processing
|
||||
#ifdef SETPOINT_THI
|
||||
if ( Thi > T_setpoint ) {
|
||||
#endif
|
||||
#ifdef SETPOINT_TS1
|
||||
if ( Ts1 > T_setpoint ) {
|
||||
#endif
|
||||
//PrintSS(F("HWP OFF"));
|
||||
lastStartMsgTxt = F("HWP_OFF");
|
||||
Tci < cT_cold_min) && (coldside_circle_state == 0) ) {
|
||||
//PrintSS(F("CWP ON by ColdMin"));
|
||||
lastStartMsgTxt = F("CWP_ON_CoMin");
|
||||
|
@ -230,7 +200,7 @@ _LO) {
|
|||
**OK:E.T.Sens.** Sensor restored<br>
|
||||
**OK:Pr.Cold** Cold side pressure restored<br>
|
||||
**OK:Pr.Hot** Hot side pressure restored<br><br>
|
||||
|
||||
**HWP_ON** hot side pump powered on<br>
|
||||
|
||||