Update README.md

This commit is contained in:
openhp 2021-03-22 10:26:05 +00:00 committed by GitHub
parent ae705179ce
commit d59af8586f
No known key found for this signature in database
GPG key ID: 4AEE18F83AFDEB23

View file

@ -141,57 +141,27 @@ qwer
**#HotSlp:_seconds_** sleepeng, last cycle temperature was > setpoint, waiting for next startup, see **HOTCIRCLE_START_EVERY** option<br>
**#HPSlp:_seconds_**" + String( (mincycle_poweroff -(unsigned long)(millis_now - millis_last_heatpump_on))/1000 );<br>
**#Tho>Max**<br>
**#Thi>Max**<br>
**#CaseCold**<br>
**#CaseHot**<br>
**#Thi>Setp.**<br>
**#Ts1>Setp.**<br>
**#Tae<RefMin**<br>
**#Tbe<RefMin**<br>
**#Tbc>Max**<br>
**#Tci<ColdMin**<br>
**#Tco<ColdMin**<br>
**#Tho>Max** T_HOT_MAX <br>
**#Thi>Max** T_HOT_MAX <br>
**#CaseCold** T_CRANKCASE_MIN <br>
**#CaseHot** T_CRANKCASE_MAX <br>
**#Thi>Setp.** hot in temperature > setpoint, so no reason to start<br>
**#Ts1>Setp.** s1 temperature > setpoint, so no reason to start, see SETPOINT_TS1 option to switch betwees Thi and Ts1 as setpoint sensor <br>
**#Tae<RefMin** After Evaporator temperature is too low, check system, see **T_COLDREF_MIN** option<br>
**#Tbe<RefMin** Before Evaporator temperature is too low, check system, see **T_COLDREF_MIN** option<br>
**#Tbc>Max** Before Condenser temperature is too high, check system, see **T_BEFORE_CONDENSER_MAX** option<br>
**#Tci<ColdMin** Cold In temperature is too low, see **T_COLD_MIN** option <br>
**#Tco<ColdMin** Cold In temperature is too high, see **T_COLD_MIN** option <br>
**#CWPpStart** coldside pump started, preparing system to start compressor<br>
**#CWPp:_seconds_** coldside pumping, preparing countdown**COLDCIRCLE_PREPARE** option<br>
**HP_Started** normal start<br>
**#CWPpStart** coldside start, preparing system to start compressor<br>
**#CWPp:"** + String( (COLDCIRCLE_PREPARE <br>
**HP_Started**<br>
**Normal_stop** normal stop, i.e. setpoint sensor temperature > setpoint, so no need to heat anymore<br>
**Normal_stop**<br>
**HWP_ON**<br>
**HWP_ON_by_ev** hot side pump started after power saving, see **HOTCIRCLE_START_EVERY** option <br>
**HWP_OFF** setpoint sensor temperature > setpoint, so hot side pump powered off and going to power saving mode, see **HOTCIRCLE_STOP_AFTER** <br>
((heatpump_state == 1) && (hotside_circle_state == 0) ) || ((_1st_start_sleeped == 0 )
(millis_now - millis_last_hotWP_on) > HOTCIRCLE_START_EVERY) ) { //process START_EVERY for hot side
millis_last_hotWP_off = millis_now;
hotside_circle_state = 1;
//PrintSS(F("HWP ON by startevery"));
lastStartMsgTxt = F("HWP_ON_by_ev");
deffered_stop_hotcircle) || millis_last_heatpump_on == 0) { //deffered stop aftret heat pump stop and correct processing of 1st start, 1st_start sleeped flag not used - there's another logic
/*
//useful for tank heater with Ts1 as setpont control and large intermediate water reservoir
if ( (ThoE == 1 && Tho < (Ts1 + cT_hotcircle_delta_min)) ||
(ThiE == 1 && Thi < (Ts1 + cT_hotcircle_delta_min)) ) {
PrintSS(F("Hot CP OFF 1"));
millis_last_hotWP_on = millis_now;
hotside_circle_state = 0;
} else {
PrintSS(F("Hot CP OFF 2"));
millis_last_hotWP_on = millis_now;
hotside_circle_state = 0;
}
*/
if ( (unsigned long)(millis_now - millis_last_hotWP_off) > HOTCIRCLE_STOP_AFTER) { //and START_EVERY processing
#ifdef SETPOINT_THI
if ( Thi > T_setpoint ) {
#endif
#ifdef SETPOINT_TS1
if ( Ts1 > T_setpoint ) {
#endif
//PrintSS(F("HWP OFF"));
lastStartMsgTxt = F("HWP_OFF");
Tci < cT_cold_min) && (coldside_circle_state == 0) ) {
//PrintSS(F("CWP ON by ColdMin"));
lastStartMsgTxt = F("CWP_ON_CoMin");
@ -230,7 +200,7 @@ _LO) {
**OK:E.T.Sens.** Sensor restored<br>
**OK:Pr.Cold** Cold side pressure restored<br>
**OK:Pr.Hot** Hot side pressure restored<br><br>
**HWP_ON** hot side pump powered on<br>
## Firmware options and fine tunings