app/vmselect: handle negative time range start in a generic manner inside NewSearchQuery()

This is a follow-up for cf03e11d89

Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5553
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/pull/5630
This commit is contained in:
Aliaksandr Valialkin 2024-01-21 23:41:11 +02:00
parent 3f7ed7e6b2
commit 1c7f990fad
No known key found for this signature in database
GPG key ID: 52C003EE2BCDB9EB
4 changed files with 5 additions and 7 deletions

View file

@ -720,9 +720,6 @@ func QueryHandler(qt *querytracer.Tracer, startTime time.Time, w http.ResponseWr
start -= offset
end := start
start = end - window
if start < 0 {
start = 0
}
// Do not include data point with a timestamp matching the lower boundary of the window as Prometheus does.
start++
if end < start {

View file

@ -1681,9 +1681,6 @@ func evalRollupFuncNoCache(qt *querytracer.Tracer, ec *EvalConfig, funcName stri
} else {
minTimestamp -= ec.Step
}
if minTimestamp < 0 {
minTimestamp = 0
}
sq := storage.NewSearchQuery(minTimestamp, ec.End, tfss, ec.MaxSeries)
rss, err := netstorage.ProcessSearchQuery(qt, sq, ec.Deadline)
if err != nil {

View file

@ -72,7 +72,7 @@ The sandbox cluster installation is running under the constant load generated by
* BUGFIX: [vmui](https://docs.victoriametrics.com/#vmui): fix a link for the statistic inaccuracy explanation in the cardinality explorer tool. See [this issue](https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5460).
* BUGFIX: [vmui](https://docs.victoriametrics.com/#vmui): send `step` param for instant queries. The change reverts [this issue](https://github.com/VictoriaMetrics/VictoriaMetrics/issues/3896) due to reasons explained in [this comment](https://github.com/VictoriaMetrics/VictoriaMetrics/issues/3896#issuecomment-1896704401).
* BUGFIX: all: fix potential panic during components shutdown when [metrics push](https://docs.victoriametrics.com/#push-metrics) is configured. See [this issue](https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5548). Thanks to @zhdd99 for the [pull request](https://github.com/VictoriaMetrics/VictoriaMetrics/pull/5549).
* BUGFIX: [vmselect](https://docs.victoriametrics.com/Cluster-VictoriaMetrics.html): properly determine time range search for instant queries with too big look-behind window like `foo[100y]`. Previously, such queries could return empty responses even if `foo` is present in database.
* BUGFIX: [MetricsQL](https://docs.victoriametrics.com/MetricsQL.html): properly process queries with too big lookbehind window such as `foo[100y]`. Previously, such queries could return empty responses even if `foo` is present in database. See [this issue](https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5553).
* BUGFIX: [MetricsQL](https://docs.victoriametrics.com/MetricsQL.html): properly handle possible negative results caused by float operations precision error in rollup functions like rate() or increase(). See [this issue](https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5571).
## [v1.96.0](https://github.com/VictoriaMetrics/VictoriaMetrics/releases/tag/v1.96.0)

View file

@ -256,6 +256,10 @@ func (sq *SearchQuery) GetTimeRange() TimeRange {
// NewSearchQuery creates new search query for the given args.
func NewSearchQuery(start, end int64, tagFilterss [][]TagFilter, maxMetrics int) *SearchQuery {
if start < 0 {
// This is needed for https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5553
start = 0
}
if maxMetrics <= 0 {
maxMetrics = 2e9
}