app/vmselect/prometheus: reduce the default value for -search.maxSeries from 100k to 30k
Production experience shows that 100k is too big for /api/v1/series . It leads to increased CPU usage when Grafana queries /api/v1/series over VictoriaMetrics with big number of time series during auto-completion and when modifying template variables.
This commit is contained in:
parent
5e22e6046d
commit
c21f5a508f
1 changed files with 1 additions and 1 deletions
|
@ -52,7 +52,7 @@ var (
|
|||
maxFederateSeries = flag.Int("search.maxFederateSeries", 1e6, "The maximum number of time series, which can be returned from /federate. This option allows limiting memory usage")
|
||||
maxExportSeries = flag.Int("search.maxExportSeries", 10e6, "The maximum number of time series, which can be returned from /api/v1/export* APIs. This option allows limiting memory usage")
|
||||
maxTSDBStatusSeries = flag.Int("search.maxTSDBStatusSeries", 10e6, "The maximum number of time series, which can be processed during the call to /api/v1/status/tsdb. This option allows limiting memory usage")
|
||||
maxSeriesLimit = flag.Int("search.maxSeries", 100e3, "The maximum number of time series, which can be returned from /api/v1/series. This option allows limiting memory usage")
|
||||
maxSeriesLimit = flag.Int("search.maxSeries", 30e3, "The maximum number of time series, which can be returned from /api/v1/series. This option allows limiting memory usage")
|
||||
)
|
||||
|
||||