The io/ioutil package is deprecated since Go1.16 - see https://tip.golang.org/doc/go1.16#ioutil
VictoriaMetrics requires at least Go1.18, so it is time to remove the io/ioutil from source code
This is a follow-up for 02ca2342ab
The ioutil.{Read|Write}File is deprecated since Go1.16 -
see https://tip.golang.org/doc/go1.16#ioutil
VictoriaMetrics needs at least Go1.18, so it is safe to remove ioutil usage
from source code.
This is a follow-up for 02ca2342ab
* Explicitly store a pointer to UserReadableError in the error interface.
Previously Go automatically converted the value to a pointer before storing in the error interface.
* Add Unwrap() method to UserReadableError, so it can be used transparently with the other code,
which calls errors.Is() and errors.As().
* Document the change in docs/CHANGELOG.md
When read query fails, VM returns rich error message with
all the details. While these details might be useful
for debugging specific cases, they're usually too verbose
for users.
Introducing a new error type `UserReadableError` is supposed
to allow to return to user only the most important parts
of the error trace. This supposed to improve error readability
in web interfaces such as VMUI or Grafana.
The full error trace is still logged with the full context
and can be found in vmselect logs.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Reduce inter-CPU communications when processing the query over big number of time series.
This should improve performance for queries over big number of time series
on systems with many CPU cores.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/2896
Based on b596ac3745
Thanks to @zqyzyq for the idea.
The change allows to specify default value for `getScrapeInterval`
function when actual interval can't be calculated.
Before the change, function were returning `maxSilenceInterval` (5m)
in such cases, which may be not correct for instant queries processing.
The specific scenario where using `maxSilenceInterval` caused issues
is the following:
1. Series becomes stale;
2. Client (in this case vmalert) continues to request series every 15s;
3. Database returns empty results as expected;
4. But at some specific moment of time database returns datapoints from `now()-5m`,
because lookback window was extended to `maxSilenceInterval`.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* vmselect: cover special cases for vmalert's routing in single-node version
* remove trailing `/` from requests
* redirect to vmalert's home page when `/vmalert` is requested.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* vmalert: fix review comments
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* Update app/vmselect/main.go
Co-authored-by: Aliaksandr Valialkin <valyala@victoriametrics.com>
- Use binary search instead of linear scan when locating the run of smallest timestamps
in blocks with intersected time ranges. This should improve performance
when merging blocks with big number of samples
- Skip samples with duplicate timestamps. This should increase query performance
in cluster version of VictoriaMetrics with the enabled replication.
- show dates in human-readable format, e.g. 2022-05-07, instead of a numeric value
- limit the maximum length of queries and filters shown in trace messages
Production experience shows that 100k is too big for /api/v1/series .
It leads to increased CPU usage when Grafana queries /api/v1/series over VictoriaMetrics
with big number of time series during auto-completion and when modifying template variables.