### Describe Your Changes
Fixed the display of hits chart in VictoriaLogs.
See #7133
### Checklist
The following checks are **mandatory**:
- [ ] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
Unpack the full columnsHeader block instead of unpacking meta-information per each individual column
when the query, which selects all the columns, is executed. This improves performance when scanning
logs with big number of fields.
- Use parallel merge of per-CPU shard results. This improves merge performance on multi-CPU systems.
- Use topN heap sort of per-shard results. This improves performance when results contain millions of entries.
1. Verify if field in [fields
pipe](https://docs.victoriametrics.com/victorialogs/logsql/#fields-pipe)
exists. If not, it generates a metric with illegal float value "" for
prometheus metrics protocol.
2. check if multiple time range filters produce conflicted query time
range, for instance:
```
query: _time: 5m | stats count(),
start:2024-10-08T10:00:00.806Z,
end: 2024-10-08T12:00:00.806Z,
time: 2024-10-10T10:02:59.806Z
```
must give no result due to invalid final time range.
---------
Co-authored-by: Aliaksandr Valialkin <valyala@victoriametrics.com>
It has been appeared that VictoriaLogs is frequently used for collecting logs with tens of fields.
For example, standard Kuberntes setup on top of Filebeat generates more than 20 fields per each log.
Such logs are also known as "wide events".
The previous storage format was optimized for logs with a few fields. When at least a single field
was referenced in the query, then the all the meta-information about all the log fields was unpacked
and parsed per each scanned block during the query. This could require a lot of additional disk IO
and CPU time when logs contain many fields. Resolve this issue by providing an (field -> metainfo_offset)
index per each field in every data block. This index allows reading and extracting only the needed
metainfo for fields used in the query. This index is stored in columnsHeaderIndexFilename ( columns_header_index.bin ).
This allows increasing performance for queries over wide events by 10x and more.
Another issue was that the data for bloom filters and field values across all the log fields except of _msg
was intermixed in two files - fieldBloomFilename ( field_bloom.bin ) and fieldValuesFilename ( field_values.bin ).
This could result in huge disk read IO overhead when some small field was referred in the query,
since the Operating System usually reads more data than requested. It reads the data from disk
in at least 4KiB blocks (usually the block size is much bigger in the range 64KiB - 512KiB).
So, if 512-byte bloom filter or values' block is read from the file, then the Operating System
reads up to 512KiB of data from disk, which results in 1000x disk read IO overhead. This overhead isn't visible
for recently accessed data, since this data is usually stored in RAM (aka Operating System page cache),
but this overhead may become very annoying when performing the query over large volumes of data
which isn't present in OS page cache.
The solution for this issue is to split bloom filters and field values across multiple shards.
This reduces the worst-case disk read IO overhead by at least Nx where N is the number of shards,
while the disk read IO overhead is completely removed in best case when the number of columns doesn't exceed N.
Currently the number of shards is 8 - see bloomValuesShardsCount . This solution increases
performance for queries over large volumes of newly ingested data by up to 1000x.
The new storage format is versioned as v1, while the old storage format is version as v0.
It is stored in the partHeader.FormatVersion.
Parts with the old storage format are converted into parts with the new storage format during background merge.
It is possible to force merge by querying /internal/force_merge HTTP endpoint - see https://docs.victoriametrics.com/victorialogs/#forced-merge .
### Describe Your Changes
Fix `Alert` component to prevent it from overflowing the screen when
displaying long messages.
Related issue: #7207
### Checklist
The following checks are **mandatory**:
- [x] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
---------
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Co-authored-by: hagen1778 <roman@victoriametrics.com>
### Describe Your Changes
- Added functionality to cancel running queries on the Explore Logs and
Query pages.
- The loader was changed from a spinner to a top bar within the block.
This still indicates loading, but solves the issue of the spinner
"flickering," especially during graph dragging.
Related issue: #7097https://github.com/user-attachments/assets/98e59aeb-905b-4b9d-bbb2-688223b22a82
### Checklist
The following checks are **mandatory**:
- [ ] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
Empty fields are treated as non-existing fields by VictoriaLogs data model.
So there is no sense in returning empty fields in query results, since they may mislead and confuse users.
s.partitions can be changed when new partition is registered or when old partition is dropped.
This could lead to data races and panics when s.partitions slice is accessed by concurrently executed queries.
The fix is to make a copy of the selected partitions under s.partitionsLock before performing the query.
Create blockResultColumn.forEachDictValue* helper functions for visiting matching
dictionary values. These helper functions should prevent from counting dictionary values
without matching logs in the future.
This is a follow-up for 0c0f013a60
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/7152
encoding.GetUint64s() returns uninitialized slice, which may contain arbitrary values.
So values in this slice must be reset to zero before using it for counting hits in `uniq` and `top` pipes.
This allows executing queries with `stats` pipe, which calculate multiple results with the same functions,
but with different `if (...)` conditions. For example:
_time:5m | count(), count() if (error)
Previously such queries couldn't be executed becasue automatically generated name for the second result
didn't include `if (error)`, so names for both results were identical - `count(*)`.
Now the following queries are equivalents:
_time:5s | sort by (_time)
_time:5s | order by (_time)
This is needed for convenience, since `order by` is commonly used in other query languages such as SQL.
### Describe Your Changes
- Show the time range in the tooltip when hovering over staircase
graphs.
- Use bolder lines for staircase graphs.
- Increase the number of steps on the staircase graph to 100.
- Reduce the maximum width of the tooltip to 1/3 of the screen.
- Insert only the label name under the cursor into the query input field
when `Ctrl`-clicking the line legend.
See [this
comment](https://github.com/VictoriaMetrics/VictoriaMetrics/issues/6545#issuecomment-2336805237).
### Checklist
The following checks are **mandatory**:
- [ ] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
---------
Co-authored-by: Aliaksandr Valialkin <valyala@victoriametrics.com>
### Describe Your Changes
1) Changed table settings from a popup to a modal window to simplify
future functionality additions.
2) Added functionality to save selected columns when data is modified or
the page is reloaded. See #7016.
<details>
<summary>Example screenshots</summary>
<img alt="demo-1" width="600"
src="https://github.com/user-attachments/assets/a5d9a910-363c-4931-8b12-18ea8b3d97d8"/>
</details>
### Checklist
The following checks are **mandatory**:
- [x] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
---------
Co-authored-by: Roman Khavronenko <roman@victoriametrics.com>
Previously only logs inside the selected time range could be returned by stream_context pipe.
For example, the following query could return up to 10 surrounding logs only for the last 5 minutes,
while most users expect this query should return up to 10 surrounding logs without restrictions on the time range.
_time:5m panic | stream_context before 10
This enables the ability to implement stream context feature at VictoriaLogs web UI: https://github.com/VictoriaMetrics/VictoriaMetrics/issues/7063 .
Reduce memory usage when returning stream context over big log streams with millions of entries.
The new logic scans over all the log messages for the selected log stream, while keeping in memory only
the given number of surrounding logs. Previously all the logs for the given log stream on the selected time range
were loaded in memory before selecting the needed surrounding logs.
This should help https://github.com/VictoriaMetrics/VictoriaMetrics/issues/6730 .
Reduce the scan performance for big log streams by fetching only the requested fields. For example, the following
query should be executed much faster than before if logs contain many fields other than _stream, _msg and _time:
panic | stream_context after 30 | fields _stream, _msg, _time
Use local timezone of the host server in this case. The timezone can be overridden
with TZ environment variable if needed.
While at it, allow using whitespace instead of T as a delimiter between data and time
in the ingested _time field. For example, '2024-09-20 10:20:30' is now accepted
during data ingestion. This is valid ISO8601 format, which is used by some log shippers,
so it should be supported. This format is also known as SQL datetime format.
Also assume local time zone when time without timezone information is passed to querying APIs.
Previously such a time was parsed in UTC timezone. Add `Z` to the end of the time string
if the old behaviour is preferred.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/6721
### Describe Your Changes
VictoriaLogs allows logs without `_msg` field or `_msg` field is empty.
This lead to incorrect search result. See:
https://github.com/VictoriaMetrics/VictoriaMetrics/issues/6785
This pull request search for non-empty `_msg` field before log entry is
added to `LogRows`.
New counter `vl_rows_dropped_total{reason="msg_not_exist"}` is
introduced.
Example log output:
```
2024-09-23T02:33:19.719Z warn app/vlinsert/insertutils/common_params.go:189 dropping log line without _msg field; [{@timestamp 2024-09-18T13:42:16.600000000Z} {Attributes.array.attribute ["many","values"]} {Attributes.boolean.attribute true} {Attributes.double.attribute 637.704} {Attributes.int.attribute 10} {Attributes.map.attribute.some.map.key some value} {Attributes.string.attribute some string} {Body Example ddddddddddlog record} {Resource.service.name my.service} {Scope.my.scope.attribute some scope attribute} {Scope.name my.library} {Scope.version 1.0.0} {SeverityNumber 10} {SeverityText Information} {SpanId eee19b7ec3c1b174} {TraceFlags 0} {TraceId 5b8efff798038103d269b633813fc60c}]
```
### Checklist
The following checks are **mandatory**:
- [x] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
- [ ] Benchmark for potential performance loss.
---------
Co-authored-by: Aliaksandr Valialkin <valyala@victoriametrics.com>