Previously bytesutil.Resize() was copying the original byte slice contents to a newly allocated slice.
This wasted CPU cycles and memory bandwidth in some places, where the original slice contents wasn't needed
after slize resizing. Switch such places to bytesutil.ResizeNoCopy().
Rename the original bytesutil.Resize() function to bytesutil.ResizeWithCopy() for the sake of improved readability.
Additionally, allocate new slice with `make()` instead of `append()`. This guarantees that the capacity of the allocated slice
exactly matches the requested size. The `append()` could return a slice with bigger capacity as an optimization for further `append()` calls.
This could result in excess memory usage when the returned byte slice was cached (for instance, in lib/blockcache).
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/2007
Previously the duration for graceful shutdown for http server could take more than a minute
because of imporperly set timeouts in setNetworkTimeout.
Now typical duration for graceful shutdown should be reduced to less than 5 seconds.