- Document the ability to read OpenTelemetry data from Amazon Firehose at docs/CHANGELOG.md
- Simplify parsing Firehose data. There is no need in trying to optimize the parsing with fastjson
and byte slice tricks, since OpenTelemetry protocol is really slooow because of over-engineering.
It is better to write clear code for better maintanability in the future.
- Move Firehose parser from /lib/protoparser/firehose to lib/protoparser/opentelemetry/firehose,
since it is used only by opentelemetry parser.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/pull/5893
* deployment: create a separate env for VictoriaLogs
The new environment consists of the following components:
* VictoriaLogs
* fluentbit for collecting logs and sending to VictoriaLogs
* VictoriaMetrics for scraping and storing metrics from fluentbit and VictoriaLogs
* Grafana with VictoriaLogs datasource for monitoring
-----------------
The motivation for creating a separate environment is to simplify existing environments
and make it easier to update or modify them in future.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Prevsiously they were swapped - the first arg should be the label name and the second arg should be label filters
This is a follow-up for e389b7b959e8144fdff5075bf7a5a39b2b0c6dd3
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5847
This solves two issues:
1. The vm_backups_uploaded_bytes_total metric will grow more smoothly
2. This prevents from int overflow at metrics.Counter.Add() when uploading files bigger than 2GiB
This should simplify code maintenance by gradually converting to atomic.* types instead of calling atomic.* functions
on int and bool types.
See ea9e2b19a5
The issue has been introduced in bace9a2501
The improper fix was in the d4c0615dcd ,
since it fixed the issue just by an accident, because Go comiler aligned the rawRowsShards field
by 4-byte boundary inside partition struct.
The proper fix is to use atomic.Int64 field - this guarantees that the access to this field
won't result in unaligned 64-bit atomic operation. See https://github.com/golang/go/issues/50860
and https://github.com/golang/go/issues/19057
It has been appeared that there are VictoriaMetrics users, who rely on the fact that
VictoriaMetrics components were closing incoming connections to -httpListenAddr every 2 minutes
by default. So let's return back this value by default in order to fix the breaking change
made at d8c1db7953 .
See https://github.com/VictoriaMetrics/VictoriaMetrics/issues/1304#issuecomment-1961891450 .
Previously the (date, metricID) entries for dates older than the last 2 days were removed.
This could lead to slow check for the (date, metricID) entry in the indexdb during ingesting historical data (aka backfilling).
The issue has been introduced in 431aa16c8d
This commit returns back limits for these endpoints, which have been removed at 5d66ee88bd ,
since it has been appeared that missing limits result in high CPU usage, while the introduced concurrency limiter
results in failed lightweight requests to these endpoints because of timeout when heavyweight requests are executed.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5055
* vmui: add a time picker to the "Logs Explorer" page #5673
* Update app/vmui/packages/vmui/src/pages/ExploreLogs/hooks/useFetchLogs.ts
---------
Co-authored-by: Aliaksandr Valialkin <valyala@victoriametrics.com>