Instead, log a sample of these long items once per 5 seconds into error log,
so users could notice and fix the issue with too long labels or too many labels.
Previously this panic could occur in production when ingesting samples with too long labels.
The 3c246cdf00 added an optimization where the previous metaindexRow
could be saved to disk when the current block header couldn't be added indexBlock because the resulting
indexBlock size became too big. This could result in an empty metaindexRow.firstItem for the next metaindexRow.
This allows removing importing unneeded command-line flags into binaries, which import lib/storage,
which, in turn, was importing lib/snapshot in order to use Time, Validate and NewName functions.
This is a follow-up for 83e55456e2
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/pull/5738
Closing client connections every 2 minutes doesn't help load balancing -
this just leads to "jumpy" connections between multiple backend servers,
e.g. the load isn't spread evenly among backend servers, and instead jumps
between the servers every 2 minutes.
It is still possible periodically closing client connections by specifying non-zero -http.connTimeout command-line flag.
This should help with https://github.com/VictoriaMetrics/VictoriaMetrics/issues/1304#issuecomment-1636997037
This is a follow-up for d387da142e
There is no sense in storing commonPrefix for blockHeader containing only a single item,
since this only increases blockHeader size without any benefits.
This panic could occur when samples with too long label values are ingested into VictoriaMetrics.
This could result in too long fistItem and commonPrefix values at blockHeader (up to 64kb each).
This may inflate the maximum index block size by 4 * maxIndexBlockSize.
For example, -fooDuration=',10s,' is now supported - it sets three command-line flag values:
- the first and the last one are set to the default value for `-fooDuration`
- the second one is set to 10s
This should significantly reduce the number of open ReaderAt files
on VictoriaMetrics and VictoriaLogs startup.
The open files can be tracked via vm_fs_readers metric
GOGC can be already set via environment variable. There is no need in adding
new approaches for setting the GOGC (such as command-line flag), since they complicate operations.
Remove temporary file before closing it in order to signal the OS that it shouldn't
store the file contents from page cache to disk when the file is closed.
Gracefully handle the case when the file cannot be removed before being closed -
in this case remove the file after closing it. This allows working on Windows.
Also remove superflouos opening of temporary file for reading - re-use already opened file handle for writing.
This is a follow-up for 9b1e002287
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/pull/4020
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/70
The easyproto-based marshaler is 2x slower than the previous custom marshaler,
so let's stick with it. This improves the performance for sending data to remote storage at vmagent
and reduces CPU usage to pre-v1.97.0 levels.
* adding support for username_file in basic_auth of scrape config
Signed-off-by: Syed Nihal <syed.nihal@nokia.com>
* adding support for username_file in basic_auth of scrape config. See https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5511
Signed-off-by: Syed Nihal <syed.nihal@nokia.com>
* adding support for username_file in basic_auth of scrape config
Signed-off-by: Syed Nihal <syed.nihal@nokia.com>
* adding support for username_file in basic_auth of scrape config
Signed-off-by: Syed Nihal <syed.nihal@nokia.com>
* adding support for username_file in basic_auth of scrape config
Signed-off-by: Syed Nihal <syed.nihal@nokia.com>
---------
Signed-off-by: Syed Nihal <syed.nihal@nokia.com>
Entries for the previous dates is usually not used, so there is little sense in keeping them in memory.
This should reduce the size of storage/date_metricID cache, which can be monitored
via vm_cache_entries{type="storage/date_metricID"} metric.
This limit has little sense for these APIs, since:
- Thses APIs frequently result in scanning of all the time series on the given time range.
For example, if extra_filters={datacenter="some_dc"} .
- Users expect these APIs shouldn't hit the -search.maxUniqueTimeseries limit,
which is intended for limiting resource usage at /api/v1/query and /api/v1/query_range requests.
Also limit the concurrency for /api/v1/labels, /api/v1/label/.../values
and /api/v1/series requests in order to limit the maximum memory usage and CPU usage for these API.
This limit shouldn't affect typical use cases for these APIs:
- Grafana dashboard load when dashboard labels should be loaded
- Auto-suggestion list load when editing the query in Grafana or vmui
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5055