Aliaksandr Valialkin
3e09d38f29
app/vmselect/promql: fix results caching for multi-arg rollup functions such as quantile_over_time
...
Previosly only a single arg was taken into account, so caching didn't work properly for multi-arg rollup funcs.
2020-01-03 20:49:08 +02:00
Aliaksandr Valialkin
b5645ccbdf
app/vmselect/promql: increase the estimated number of time series returned by aggr() by (something)
from 100 to 1K, since 100 may result in OOM for high number of time series
2020-01-03 01:02:21 +02:00
Aliaksandr Valialkin
1925ee038d
Rename lib/promql to lib/metricsql and apply small fixes
2019-12-25 22:03:59 +02:00
Mike Poindexter
bec62e4e43
Split Extended PromQL parsing to a separate library
2019-12-25 22:03:51 +02:00
Aliaksandr Valialkin
d880325cf6
app/vmselect/promql: make sure AdjustStartEnd returns time range covering the same number of points as the initial time range
...
This should prevent from the following panic at app/vmselect/promql/binary_op.go:255:
BUG: len(leftVaues) must match len(rightValues) and len(dstValues)
2019-12-24 22:45:56 +02:00
Aliaksandr Valialkin
3c076544bf
app/vmselect/promql: allow negative offsets
...
Updates https://github.com/prometheus/prometheus/issues/6282
2019-12-11 01:00:23 +02:00
Aliaksandr Valialkin
63b05c0b9f
app/vmselect/promql: adjust memory limits calculations for incremental aggregate functions
...
Incremental aggregate functions don't keep all the selected time series in memory -
they keep only up to GOMAXPROCS time series for incremental aggregations.
Take into account that the number of time series in RAM can be higher if they are split
into many groups with `by (...)` or `without (...)` modifiers.
This should reduce the number of `not enough memory for processing ... data points` false
positive errors.
2019-11-08 21:21:07 +02:00
Aliaksandr Valialkin
c66a691593
app/vmselect/prometheus: add -search.maxLookback
command-line flag for overriding dynamic calculations for max lookback interval
...
This flag is similar to `-search.lookback-delta` if set. The max lookback interval is determined dynamically
from interval between datapoints for each input time series if the flag isn't set.
The interval can be overriden on per-query basis by passing `max_lookback=<duration>` query arg to `/api/v1/query` and `/api/v1/query_range`.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/209
2019-10-15 21:31:48 +03:00
Aliaksandr Valialkin
d4218d27e6
app/vmselect/promql: properly handle subqueries like aggr_func(rollup_func(metric[window:step]))
...
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/184
2019-09-13 21:41:04 +03:00
Aliaksandr Valialkin
47e4b50112
app/vmselect: optimize /api/v1/series
by skipping storage data
...
Fetch and process only time series metainfo.
2019-08-04 23:01:28 +03:00
Aliaksandr Valialkin
66efa5745f
app/vmselect/promql: properly calculate incremental aggregations grouped by __name__
...
Previously the following query may fail on multiple distinct metric names match:
sum(count_over_time{__name__!=''}) by (__name__)
2019-07-25 21:53:20 +03:00
Aliaksandr Valialkin
ab88890523
app/vmselect/promql: parallelize incremental aggregation to multiple CPU cores
...
This may reduce response times for aggregation over big number of time series
with small step between output data points.
2019-07-12 15:52:22 +03:00
Aliaksandr Valialkin
a336bb4e22
app/vmselect/promql: reduce RAM usage for aggregates over big number of time series
...
Calculate incremental aggregates for `aggr(metric_selector)` function instead of
keeping all the time series matching the given `metric_selector` in memory.
2019-07-10 13:04:39 +03:00
Aliaksandr Valialkin
74c0fb04f3
app/vmselect/promql: consistency renaming: candlestick -> rollup_candlestick
2019-06-29 03:13:02 +03:00
Aliaksandr Valialkin
796b010139
app/vmselect: add candlestick(m[d])
func for returning open
, close
, low
and high
rollups on the given time range d
...
This function is frequently used in financial apps. See https://en.wikipedia.org/wiki/Candlestick_chart
2019-06-27 18:46:13 +03:00
Aliaksandr Valialkin
feacfffe89
app/vmselect/promql: increase default value for -search.maxPointsPerTimeSeries from 10k to 30k
...
This may be required for subqueries with small steps. See https://github.com/VictoriaMetrics/VictoriaMetrics/issues/77
2019-06-24 22:53:18 +03:00
Aliaksandr Valialkin
61926bae01
app/vmselect/promql: adjust the provided window only for range functions with dt in denominator
...
This should fix range function calculations such as `changes(m[d])` where `d` is smaller
than the scrape interval.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/72
2019-06-23 19:27:31 +03:00
Aliaksandr Valialkin
9e1119dab8
app/vmselect/promql: ajdust data model to the model used in Prometheus
...
Do not take into account data points on the range `[timestamp .. timestamp+step)`
when calculating value on the given `timestamp`.
Use only data points from the past when performing these calculations like Prometheus does.
This should reduce discrepancies between results returned by VictoriaMetrics
and results returned by Prometheus.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/72
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/71
2019-06-21 21:54:48 +03:00
Aliaksandr Valialkin
beb479b8f1
app/vmselect/promql: use dynamic limit on memory for concurrent queries
2019-06-12 23:18:44 +03:00
Aliaksandr Valialkin
54fb8b21f9
all: fix misspellings
2019-05-25 21:51:11 +03:00
Aliaksandr Valialkin
1836c415e6
all: open-sourcing single-node version
2019-05-23 00:18:06 +03:00