This should improve maintainability of the code related to rollup functions,
since it is located in rollup.go
While at it, properly return empty results from holt_winters(), rate_over_sum(),
sum2_over_time(), geomean_over_time() and distinct_over_time() when there are no real samples
on the selected lookbehind window. Previously the previous sample value was mistakenly
returned from these functions.
changes(), increases_over_time() and resets() shouldn't take into account
value changes, which may occur because of precision errors.
The maximum guaranteed precision for raw samples stored in VictoriaMetrics is 12 decimal digits.
So do not count relative changes for values if they are smaller than 1e-12 comparing to the value.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/767
Remove temporary file before closing it in order to signal the OS that it shouldn't
store the file contents from page cache to disk when the file is closed.
Gracefully handle the case when the file cannot be removed before being closed -
in this case remove the file after closing it. This allows working on Windows.
Also remove superflouos opening of temporary file for reading - re-use already opened file handle for writing.
This is a follow-up for 9b1e002287
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/pull/4020
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/70
This case is possible after a new brsPool is allocated. The fix is to verify whether len(brsPool) >= len(brs.brs)
before trying to append a new item to brsPool and sharing its contents with brs.brs.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5733
* app/vmselect: set proper timestamp for cached instant responses
The change updates `getSumInstantValues` to prefer timestamp
from the most recent results. Before, timestamp from cached series
was used.
The old behavior had negative impact on recording rules as they
were getting responses with shifted timestamps in past.
Subsequent recording or alerting rules fetching results of these
recording rules could get no result due to staleness interval.
https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5659
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* wip
---------
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Co-authored-by: Aliaksandr Valialkin <valyala@victoriametrics.com>
This limit has little sense for these APIs, since:
- Thses APIs frequently result in scanning of all the time series on the given time range.
For example, if extra_filters={datacenter="some_dc"} .
- Users expect these APIs shouldn't hit the -search.maxUniqueTimeseries limit,
which is intended for limiting resource usage at /api/v1/query and /api/v1/query_range requests.
Also limit the concurrency for /api/v1/labels, /api/v1/label/.../values
and /api/v1/series requests in order to limit the maximum memory usage and CPU usage for these API.
This limit shouldn't affect typical use cases for these APIs:
- Grafana dashboard load when dashboard labels should be loaded
- Auto-suggestion list load when editing the query in Grafana or vmui
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5055
This reduces the number of memory allocations at the cost of possible memory usage increase,
since now different metric name strings may hold references to the previous byte slice.
This is good tradeoff, since ProcessSearchQuery is called in vmselect, and vmselect isn't usually limited by memory.
This change has been extracted from https://github.com/VictoriaMetrics/VictoriaMetrics/pull/5527
Examples:
1) -metricsAuthKey=file:///abs/path/to/file - reads flag value from the given absolute filepath
2) -metricsAuthKey=file://./relative/path/to/file - reads flag value from the given relative filepath
3) -metricsAuthKey=http://some-host/some/path?query_arg=abc - reads flag value from the given url
The flag value is automatically updated when the file contents changes.
* app/vmselect/promql: properly handle possible negative results caused by float operations precision error in rollup functions like rate() or increase()
* fix test
Properly determine time range search for instant queries with too big look-behind window like `foo[100y]`.
Previously, such queries could return empty responses even if `foo` is present in database.
https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5553
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* app/vmselect: drop `rollupDefault` function as duplicate
It is unclear why there are two identical fns `rollupDefault`
and `rollupDistinct`. Dropping one of them.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* Update app/vmselect/promql/rollup.go
* Update app/vmselect/promql/rollup.go
---------
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Co-authored-by: Aliaksandr Valialkin <valyala@victoriametrics.com>
app/vmselect/promql/eval.go:evalAggrFunc shunts evaluation
of AggrFuncExpr over rollupFunc over MetricsExpr to an optimized
path. tryGetArgRollupFuncWithMetricExpr() checks whether expression
can be shunted, but it mangles the AggrFuncExpr when the aggregation
function has more than one argument. This results in queries like
`sum(aggr_over_time("avg_over_time",m))` failing with error message
'expecting at least 2 args to "aggr_over_time"; got 1 args' while
the analogous query `sum(avg_over_time(m))` executes successfully.
This fix removes the unnecessary mangling.
Signed-off-by: Anton Tykhyy <atykhyy@gmail.com>