--- title: Reader weight: 2 menu: docs: parent: "vmanomaly-components" weight: 2 aliases: - /anomaly-detection/components/reader.html --- VictoriaMetrics Anomaly Detection (`vmanomaly`) primarily uses [VmReader](#vm-reader) to ingest data. This reader focuses on fetching time-series data directly from VictoriaMetrics with the help of powerful [MetricsQL](https://docs.victoriametrics.com/metricsql/) expressions for aggregating, filtering and grouping your data, ensuring seamless integration and efficient data handling. Future updates will introduce additional readers, expanding the range of data sources `vmanomaly` can work with. ## VM reader > **Note**: Starting from [v1.13.0](https://docs.victoriametrics.com/anomaly-detection/changelog/#v1130) there is backward-compatible change of [`queries`](https://docs.victoriametrics.com/anomaly-detection/components/reader?highlight=queries#vm-reader) arg of [VmReader](#vm-reader). New format allows to specify per-query parameters, like `step` to reduce amount of data read from VictoriaMetrics TSDB and to allow config flexibility. Please see [per-query parameters](#per-query-parameters) section for the details. Old format like ```yaml # other config sections ... reader: class: 'vm' datasource_url: 'http://localhost:8428' # source victoriametrics/prometheus sampling_period: "10s" # set it <= min(infer_every) in schedulers section queries: # old format {query_alias: query_expr}, prior to 1.13, will be converted to a new format automatically vmb: 'avg(vm_blocks)' ``` will be converted to a new one with a warning raised in logs: ```yaml # other config sections ... reader: class: 'vm' datasource_url: 'http://localhost:8428' # source victoriametrics/prometheus sampling_period: '10s' queries: # old format {query_alias: query_expr}, prior to 1.13, will be converted to a new format automatically vmb: expr: 'avg(vm_blocks)' # initial MetricsQL expression step: '10s' # individual step for this query, will be filled with `sampling_period` from the root level data_range: ['-inf', 'inf'] # by default, no constraints applied on data range # new query-level arguments will be added in backward-compatible way in future releases ``` ### Per-query parameters Starting from [v1.13.0](https://docs.victoriametrics.com/anomaly-detection/changelog/#v1130) there is change of [`queries`](https://docs.victoriametrics.com/anomaly-detection/components/reader?highlight=queries#vm-reader) arg format. Now each query alias supports the next (sub)fields: - `expr` (string): MetricsQL/PromQL expression that defines an input for VmReader. As accepted by `/query_range?query=%s`. i.e. `avg(vm_blocks)` - `step` (string): query-level frequency of the points returned, i.e. `30s`. Will be converted to `/query_range?step=%s` param (in seconds). Useful to optimize total amount of data read from VictoriaMetrics, where different queries may have **different frequencies for different [machine learning models](https://docs.victoriametrics.com/anomaly-detection/components/models)** to run on. > **Note**: if not set explicitly (or if older config style prior to [v1.13.0](https://docs.victoriametrics.com/anomaly-detection/changelog/#v1130)) is used, then it is set to reader-level `sampling_period` arg. > **Note**: having **different** individual `step` args for queries (i.e. `30s` for `q1` and `2m` for `q2`) is not yet supported for [multivariate model](https://docs.victoriametrics.com/anomaly-detection/components/models/#multivariate-models) if you want to run it on several queries simultaneously (i.e. setting [`queries`](https://docs.victoriametrics.com/anomaly-detection/components/models/#queries) arg of a model to [`q1`, `q2`]). - `data_range` (list[float | string]): Introduced in [v1.15.1](https://docs.victoriametrics.com/anomaly-detection/changelog/#v1151), it allows defining **valid** data ranges for input per individual query in `queries`, resulting in: - **High anomaly scores** (>1) when the *data falls outside the expected range*, indicating a data constraint violation. - **Lowest anomaly scores** (=0) when the *model's predictions (`yhat`) fall outside the expected range*, meaning uncertain predictions. - `max_points_per_query` (int): Introduced in [v1.17.0](https://docs.victoriametrics.com/anomaly-detection/changelog/#v1170), optional arg overrides how `search.maxPointsPerTimeseries` flag (available since [v1.14.1](#v1141)) impacts `vmanomaly` on splitting long `fit_window` [queries](https://docs.victoriametrics.com/anomaly-detection/components/reader/?highlight=queries#vm-reader) into smaller sub-intervals. This helps users avoid hitting the `search.maxQueryDuration` limit for individual queries by distributing initial query across multiple subquery requests with minimal overhead. Set less than `search.maxPointsPerTimeseries` if hitting `maxQueryDuration` limits. If set on a query-level, it overrides the global `max_points_per_query` (reader-level). ### Per-query config example ```yaml reader: class: 'vm' sampling_period: '1m' max_points_per_query: 10000 # other reader params ... queries: ingestion_rate: expr: 'sum(rate(vm_rows_inserted_total[5m])) by (type) > 0' step: '2m' # overrides global `sampling_period` of 1m data_range: [10, 'inf'] # meaning only positive values > 10 are expected, i.e. a value `y` < 10 will trigger anomaly score > 1 max_points_per_query: 5000 # overrides reader-level value of 10000 for `ingestion_rate` query ``` ### Config parameters
Parameter | Example | Description |
---|---|---|
`class` | `reader.vm.VmReader` (or `vm` starting from [v1.13.0](https://docs.victoriametrics.com/anomaly-detection/changelog/#v1130)) | Name of the class needed to enable reading from VictoriaMetrics or Prometheus. VmReader is the default option, if not specified. |
`queries` | See [per-query config example](#per-query-config-example) above | See [per-query config section](#per-query-parameters) above |
`datasource_url` | `http://localhost:8481/` | Datasource URL address |
`tenant_id` | `0:0`, `multitenant` | For VictoriaMetrics Cluster version only, tenants are identified by `accountID` or `accountID:projectID`. Starting from [v1.16.2](https://docs.victoriametrics.com/anomaly-detection/changelog/#v1162), `multitenant` [endpoint](https://docs.victoriametrics.com/cluster-victoriametrics/?highlight=reads#multitenancy-via-labels) is supported, to execute queries over multiple [tenants](https://docs.victoriametrics.com/cluster-victoriametrics/#multitenancy). See VictoriaMetrics Cluster [multitenancy docs](https://docs.victoriametrics.com/cluster-victoriametrics/#multitenancy) |
`sampling_period` | `1h` | Frequency of the points returned. Will be converted to `/query_range?step=%s` param (in seconds). **Required** since [v1.9.0](https://docs.victoriametrics.com/anomaly-detection/changelog/#v190). |
`query_range_path` | `/api/v1/query_range` | Performs PromQL/MetricsQL range query |
`health_path` | `health` | Absolute or relative URL address where to check availability of the datasource. |
`user` | `USERNAME` | BasicAuth username |
`password` | `PASSWORD` | BasicAuth password |
`timeout` | `30s` | Timeout for the requests, passed as a string |
`verify_tls` | `false` | Verify TLS certificate. If `False`, it will not verify the TLS certificate. If `True`, it will verify the certificate using the system's CA store. If a path to a CA bundle file (like `ca.crt`), it will verify the certificate using the provided CA bundle. |
`tls_cert_file` | `path/to/cert.crt` | Path to a file with the client certificate, i.e. `client.crt`. Available since [v1.16.3](https://docs.victoriametrics.com/anomaly-detection/changelog/#v1163). |
`tls_key_file` | `path/to/key.crt` | Path to a file with the client certificate key, i.e. `client.key`. Available since [v1.16.3](https://docs.victoriametrics.com/anomaly-detection/changelog/#v1163). |
`bearer_token` | `token` | Token is passed in the standard format with header: `Authorization: bearer {token}` |
`bearer_token_file` | `path_to_file` | Path to a file, which contains token, that is passed in the standard format with header: `Authorization: bearer {token}`. Available since [v1.15.9](https://docs.victoriametrics.com/anomaly-detection/changelog/#v1159) |
`extra_filters` | `[]` | List of strings with series selector. See: [Prometheus querying API enhancements](https://docs.victoriametrics.com/##prometheus-querying-api-enhancements) |
`query_from_last_seen_timestamp` | `False` | If True, then query will be performed from the last seen timestamp for a given series. If False, then query will be performed from the start timestamp, based on a schedule period. Defaults to `False`. Useful for `infer` stages in case there were skipped `infer` calls prior to given. |
`latency_offset` | `1ms` | Introduced in [v1.15.1](https://docs.victoriametrics.com/anomaly-detection/changelog/#v1151), it allows overriding the default `-search.latencyOffset` [flag of VictoriaMetrics](https://docs.victoriametrics.com/?highlight=search.latencyOffset#list-of-command-line-flags) (30s). The default value is set to 1ms, which should help in cases where `sampling_frequency` is low (10-60s) and `sampling_frequency` equals `infer_every` in the [PeriodicScheduler](https://docs.victoriametrics.com/anomaly-detection/components/scheduler/?highlight=infer_every#periodic-scheduler). This prevents users from receiving `service - WARNING - [Scheduler [scheduler_alias]] No data available for inference.` warnings in logs and allows for consecutive `infer` calls without gaps. To restore the old behavior, set it equal to your `-search.latencyOffset` [flag value]((https://docs.victoriametrics.com/?highlight=search.latencyOffset#list-of-command-line-flags)). |
`max_points_per_query` | `10000` | Introduced in [v1.17.0](https://docs.victoriametrics.com/anomaly-detection/changelog/#v1170), optional arg overrides how `search.maxPointsPerTimeseries` flag (available since [v1.14.1](#v1141)) impacts `vmanomaly` on splitting long `fit_window` [queries](https://docs.victoriametrics.com/anomaly-detection/components/reader/?highlight=queries#vm-reader) into smaller sub-intervals. This helps users avoid hitting the `search.maxQueryDuration` limit for individual queries by distributing initial query across multiple subquery requests with minimal overhead. Set less than `search.maxPointsPerTimeseries` if hitting `maxQueryDuration` limits. You can also set it on [per-query](#per-query-parameters) basis to override this global one. |