# This is a reduced version of awesome alerts 2023-12-01.1 groups: - name: AwesomeAlerts rules: - alert: HostOutOfMemory expr: (node_memory_MemAvailable_bytes / node_memory_MemTotal_bytes * 100 < 10) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 2m labels: severity: warning annotations: summary: Host out of memory (instance {{ $labels.instance }}) description: "Node memory is filling up (< 10% left)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostMemoryIsUnderutilized expr: (100 - (rate(node_memory_MemAvailable_bytes[30m]) / node_memory_MemTotal_bytes * 100) < 20) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 1w labels: severity: info annotations: summary: Host Memory is underutilized (instance {{ $labels.instance }}) description: "Node memory is < 20% for 1 week. Consider reducing memory space. (instance {{ $labels.instance }})\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostUnusualDiskReadRate expr: (sum by (instance) (rate(node_disk_read_bytes_total[2m])) / 1024 / 1024 > 50) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 5m labels: severity: warning annotations: summary: Host unusual disk read rate (instance {{ $labels.instance }}) description: "Disk is probably reading too much data (> 50 MB/s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostUnusualDiskWriteRate expr: (sum by (instance) (rate(node_disk_written_bytes_total[2m])) / 1024 / 1024 > 50) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 2m labels: severity: warning annotations: summary: Host unusual disk write rate (instance {{ $labels.instance }}) description: "Disk is probably writing too much data (> 50 MB/s)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostOutOfDiskSpace expr: ((node_filesystem_avail_bytes * 100) / node_filesystem_size_bytes < 10 and ON (instance, device, mountpoint) node_filesystem_readonly == 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 2m labels: severity: warning annotations: summary: Host out of disk space (instance {{ $labels.instance }}) description: "Disk is almost full (< 10% left)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostDiskWillFillIn24Hours expr: ((node_filesystem_avail_bytes * 100) / node_filesystem_size_bytes < 10 and ON (instance, device, mountpoint) predict_linear(node_filesystem_avail_bytes{fstype!~"tmpfs"}[1h], 24 * 3600) < 0 and ON (instance, device, mountpoint) node_filesystem_readonly == 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 2m labels: severity: warning annotations: summary: Host disk will fill in 24 hours (instance {{ $labels.instance }}) description: "Filesystem is predicted to run out of space within the next 24 hours at current write rate\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostOutOfInodes expr: (node_filesystem_files_free / node_filesystem_files * 100 < 10 and ON (instance, device, mountpoint) node_filesystem_readonly == 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 2m labels: severity: warning annotations: summary: Host out of inodes (instance {{ $labels.instance }}) description: "Disk is almost running out of available inodes (< 10% left)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostFilesystemDeviceError expr: node_filesystem_device_error == 1 for: 0m labels: severity: critical annotations: summary: Host filesystem device error (instance {{ $labels.instance }}) description: "{{ $labels.instance }}: Device error with the {{ $labels.mountpoint }} filesystem\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostInodesWillFillIn24Hours expr: (node_filesystem_files_free / node_filesystem_files * 100 < 10 and predict_linear(node_filesystem_files_free[1h], 24 * 3600) < 0 and ON (instance, device, mountpoint) node_filesystem_readonly == 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 2m labels: severity: warning annotations: summary: Host inodes will fill in 24 hours (instance {{ $labels.instance }}) description: "Filesystem is predicted to run out of inodes within the next 24 hours at current write rate\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostUnusualDiskIo expr: (rate(node_disk_io_time_seconds_total[1m]) > 0.5) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 5m labels: severity: warning annotations: summary: Host unusual disk IO (instance {{ $labels.instance }}) description: "Time spent in IO is too high on {{ $labels.instance }}. Check storage for issues.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostSwapIsFillingUp expr: ((1 - (node_memory_SwapFree_bytes / node_memory_SwapTotal_bytes)) * 100 > 80) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 2m labels: severity: warning annotations: summary: Host swap is filling up (instance {{ $labels.instance }}) description: "Swap is filling up (>80%)\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostSystemdServiceCrashed expr: (node_systemd_unit_state{state="failed"} == 1) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 0m labels: severity: warning annotations: summary: Host systemd service crashed (instance {{ $labels.instance }}) description: "systemd service crashed\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostPhysicalComponentTooHot expr: ((node_hwmon_temp_celsius * ignoring(label) group_left(instance, job, node, sensor) node_hwmon_sensor_label{label!="tctl"} > 75)) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 5m labels: severity: warning annotations: summary: Host physical component too hot (instance {{ $labels.instance }}) description: "Physical hardware component too hot\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostNodeOvertemperatureAlarm expr: (node_hwmon_temp_crit_alarm_celsius == 1) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 0m labels: severity: critical annotations: summary: Host node overtemperature alarm (instance {{ $labels.instance }}) description: "Physical node temperature alarm triggered\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostRaidArrayGotInactive expr: (node_md_state{state="inactive"} > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 0m labels: severity: critical annotations: summary: Host RAID array got inactive (instance {{ $labels.instance }}) description: "RAID array {{ $labels.device }} is in a degraded state due to one or more disk failures. The number of spare drives is insufficient to fix the issue automatically.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostRaidDiskFailure expr: (node_md_disks{state="failed"} > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 2m labels: severity: warning annotations: summary: Host RAID disk failure (instance {{ $labels.instance }}) description: "At least one device in RAID array on {{ $labels.instance }} failed. Array {{ $labels.md_device }} needs attention and possibly a disk swap\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostKernelVersionDeviations expr: (count(sum(label_replace(node_uname_info, "kernel", "$1", "release", "([0-9]+.[0-9]+.[0-9]+).*")) by (kernel)) > 1) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 6h labels: severity: warning annotations: summary: Host kernel version deviations (instance {{ $labels.instance }}) description: "Different kernel versions are running\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostOomKillDetected expr: (increase(node_vmstat_oom_kill[1m]) > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 0m labels: severity: warning annotations: summary: Host OOM kill detected (instance {{ $labels.instance }}) description: "OOM kill detected\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostEdacCorrectableErrorsDetected expr: (increase(node_edac_correctable_errors_total[1m]) > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 0m labels: severity: info annotations: summary: Host EDAC Correctable Errors detected (instance {{ $labels.instance }}) description: "Host {{ $labels.instance }} has had {{ printf \"%.0f\" $value }} correctable memory errors reported by EDAC in the last 5 minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostEdacUncorrectableErrorsDetected expr: (node_edac_uncorrectable_errors_total > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 0m labels: severity: warning annotations: summary: Host EDAC Uncorrectable Errors detected (instance {{ $labels.instance }}) description: "Host {{ $labels.instance }} has had {{ printf \"%.0f\" $value }} uncorrectable memory errors reported by EDAC in the last 5 minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostNetworkInterfaceSaturated expr: ((rate(node_network_receive_bytes_total{device!~"^tap.*|^vnet.*|^veth.*|^tun.*"}[1m]) + rate(node_network_transmit_bytes_total{device!~"^tap.*|^vnet.*|^veth.*|^tun.*"}[1m])) / node_network_speed_bytes{device!~"^tap.*|^vnet.*|^veth.*|^tun.*"} > 0.8 < 10000) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 1m labels: severity: warning annotations: summary: Host Network Interface Saturated (instance {{ $labels.instance }}) description: "The network interface \"{{ $labels.device }}\" on \"{{ $labels.instance }}\" is getting overloaded.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostNetworkBondDegraded expr: ((node_bonding_active - node_bonding_slaves) != 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 2m labels: severity: warning annotations: summary: Host Network Bond Degraded (instance {{ $labels.instance }}) description: "Bond \"{{ $labels.device }}\" degraded on \"{{ $labels.instance }}\".\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostConntrackLimit expr: (node_nf_conntrack_entries / node_nf_conntrack_entries_limit > 0.8) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 5m labels: severity: warning annotations: summary: Host conntrack limit (instance {{ $labels.instance }}) description: "The number of conntrack is approaching limit\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostClockSkew expr: ((node_timex_offset_seconds > 0.05 and deriv(node_timex_offset_seconds[5m]) >= 0) or (node_timex_offset_seconds < -0.05 and deriv(node_timex_offset_seconds[5m]) <= 0)) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 10m labels: severity: warning annotations: summary: Host clock skew (instance {{ $labels.instance }}) description: "Clock skew detected. Clock is out of sync. Ensure NTP is configured correctly on this host.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostClockNotSynchronising expr: (min_over_time(node_timex_sync_status[1m]) == 0 and node_timex_maxerror_seconds >= 16) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 2m labels: severity: warning annotations: summary: Host clock not synchronising (instance {{ $labels.instance }}) description: "Clock not synchronising. Ensure NTP is configured on this host.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}" - alert: HostRequiresReboot expr: (node_reboot_required > 0) * on(instance) group_left (nodename) node_uname_info{nodename=~".+"} for: 4h labels: severity: info annotations: summary: Host requires reboot (instance {{ $labels.instance }}) description: "{{ $labels.instance }} requires a reboot.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"