[VictoriaLogs](https://docs.victoriametrics.com/victorialogs/) can accept logs in [Syslog formats](https://en.wikipedia.org/wiki/Syslog) at the specified TCP and UDP addresses
|
|
via `-syslog.listenAddr.tcp` and `-syslog.listenAddr.udp` command-line flags. The following syslog formats are supported:
|
|
|
|
- [RFC3164](https://datatracker.ietf.org/doc/html/rfc3164) aka `<PRI>MMM DD hh:mm:ss HOSTNAME APP-NAME[PROCID]: MESSAGE`
|
|
- [RFC5424](https://datatracker.ietf.org/doc/html/rfc5424) aka `<PRI>1 TIMESTAMP HOSTNAME APP-NAME PROCID MSGID [STRUCTURED-DATA] MESSAGE`
|
|
|
|
For example, the following command starts VictoriaLogs, which accepts logs in Syslog format at TCP port 514 on all the network interfaces:
|
|
|
|
```sh
|
|
./victoria-logs -syslog.listenAddr.tcp=:514
|
|
```
|
|
|
|
It may be needed to run VictoriaLogs under `root` user or to set [`CAP_NET_BIND_SERVICE`](https://superuser.com/questions/710253/allow-non-root-process-to-bind-to-port-80-and-443)
|
|
option if syslog messages must be accepted at TCP port below 1024.
|
|
|
|
The following command starts VictoriaLogs, which accepts logs in Syslog format at TCP and UDP ports 514:
|
|
|
|
```sh
|
|
./victoria-logs -syslog.listenAddr.tcp=:514 -syslog.listenAddr.udp=:514
|
|
```
|
|
|
|
VictoriaLogs can accept logs from the following syslog collectors:
|
|
|
|
- [Rsyslog](https://www.rsyslog.com/). See [these docs](#rsyslog).
|
|
- [Syslog-ng](https://www.syslog-ng.com/). See [these docs](#syslog-ng).
|
|
|
|
Multiple logs in Syslog format can be ingested via a single TCP connection or via a single UDP packet - just put every log on a separate line
|
|
and delimit them with `\n` char.
|
|
|
|
VictoriaLogs automatically extracts the following [log fields](https://docs.victoriametrics.com/victorialogs/keyconcepts/#data-model)
|
|
from the received Syslog lines:
|
|
|
|
- [`_time`](https://docs.victoriametrics.com/victorialogs/keyconcepts/#time-field) - log timestamp. See also [log timestamps](#log-timestamps)
|
|
- [`_msg`](https://docs.victoriametrics.com/victorialogs/keyconcepts/#message-field) - the `MESSAGE` field from the supported syslog formats above
|
|
- `hostname`, `app_name` and `proc_id` - for unique identification of [log streams](https://docs.victoriametrics.com/victorialogs/keyconcepts/#stream-fields).
|
|
It is possible to change the list of fields for log streams - see [these docs](#stream-fields).
|
|
- `priority`, `facility` and `severity` - these fields are extracted from `<PRI>` field
|
|
- `format` - this field is set to either `rfc3164` or `rfc5424` depending on the format of the parsed syslog line
|
|
- `msg_id` - `MSGID` field from log line in `RFC5424` format.
|
|
|
|
The `[STRUCTURED-DATA]` is parsed into fields with the `SD-ID.param1`, `SD-ID.param2`, ..., `SD-ID.paramN` names and the corresponding values
|
|
according to [the specification](https://datatracker.ietf.org/doc/html/rfc5424#section-6.3).
|
|
|
|
By default local timezone is used when parsing timestamps in `rfc3164` lines. This can be changed to any desired timezone via `-syslog.timezone` command-line flag.
|
|
See [the list of supported timezone identifiers](https://en.wikipedia.org/wiki/List_of_tz_database_time_zones). For example, the following command starts VictoriaLogs,
|
|
which parses syslog timestamps in `rfc3164` using `Europe/Berlin` timezone:
|
|
|
|
```sh
|
|
./victoria-logs -syslog.listenAddr.tcp=:514 -syslog.timezone='Europe/Berlin'
|
|
```
|
|
|
|
The ingested logs can be queried via [logs querying API](https://docs.victoriametrics.com/victorialogs/querying/#http-api). For example, the following command
|
|
returns ingested logs for the last 5 minutes by using [time filter](https://docs.victoriametrics.com/victorialogs/logsql/#time-filter):
|
|
|
|
```sh
|
|
curl http://localhost:9428/select/logsql/query -d 'query=_time:5m'
|
|
```
|
|
|
|
See also:
|
|
|
|
- [Log timestamps](#log-timestamps)
|
|
- [Security](#security)
|
|
- [Compression](#compression)
|
|
- [Multitenancy](#multitenancy)
|
|
- [Stream fields](#stream-fields)
|
|
- [Dropping fields](#dropping-fields)
|
|
- [Adding extra fields](#adding-extra-fields)
|
|
- [Data ingestion troubleshooting](https://docs.victoriametrics.com/victorialogs/data-ingestion/#troubleshooting).
|
|
- [How to query VictoriaLogs](https://docs.victoriametrics.com/victorialogs/querying/).
|
|
|
|
## Log timestamps
|
|
|
|
By default VictoriaLogs uses the timestamp from the parsed Syslog message as [`_time` field](https://docs.victoriametrics.com/victorialogs/keyconcepts/#time-field).
|
|
Sometimes the ingested Syslog messages may contain incorrect timestamps (for example, timestamps with incorrect timezone). In this case VictoriaLogs can be configured
|
|
for using the log ingestion timestamp as [`_time` field](https://docs.victoriametrics.com/victorialogs/keyconcepts/#time-field). This can be done by specifying
|
|
`-syslog.useLocalTimestamp.tcp` command-line flag for the corresponding `-syslog.listenAddr.tcp` address:
|
|
|
|
```sh
|
|
./victoria-logs -syslog.listenAddr.tcp=:514 -syslog.useLocalTimestamp.tcp
|
|
```
|
|
|
|
In this case the original timestamp from the Syslog message is stored in `timestamp` [log field](https://docs.victoriametrics.com/victorialogs/keyconcepts/#data-model).
|
|
|
|
The `-syslog.useLocalTimestamp.udp` command-line flag can be used for instructing VictoriaLogs to use local timestamps for the ingested logs
|
|
via the corresponding `-syslog.listenAddr.udp` address:
|
|
|
|
```sh
|
|
./victoria-logs -syslog.listenAddr.udp=:514 -syslog.useLocalTimestamp.udp
|
|
```
|
|
|
|
## Security
|
|
|
|
By default VictoriaLogs accepts plaintext data at `-syslog.listenAddr.tcp` address. Run VictoriaLogs with `-syslog.tls` command-line flag
|
|
in order to accept TLS-encrypted logs at `-syslog.listenAddr.tcp` address. The `-syslog.tlsCertFile` and `-syslog.tlsKeyFile` command-line flags
|
|
must be set to paths to TLS certificate file and TLS key file if `-syslog.tls` is set. For example, the following command
|
|
starts VictoriaLogs, which accepts TLS-encrypted syslog messages at TCP port 6514:
|
|
|
|
```sh
|
|
./victoria-logs -syslog.listenAddr.tcp=:6514 -syslog.tls -syslog.tlsCertFile=/path/to/tls/cert -syslog.tlsKeyFile=/path/to/tls/key
|
|
```
|
|
|
|
## Compression
|
|
|
|
By default VictoriaLogs accepts uncompressed log messages in Syslog format at `-syslog.listenAddr.tcp` and `-syslog.listenAddr.udp` addresses.
|
|
It is possible configuring VictoriaLogs to accept compressed log messages via `-syslog.compressMethod.tcp` and `-syslog.compressMethod.udp` command-line flags.
|
|
The following compression methods are supported:
|
|
|
|
- `none` - no compression
|
|
- `gzip` - [gzip compression](https://en.wikipedia.org/wiki/Gzip)
|
|
- `deflate` - [deflate compression](https://en.wikipedia.org/wiki/Deflate)
|
|
|
|
For example, the following command starts VictoriaLogs, which accepts gzip-compressed syslog messages at TCP port 514:
|
|
|
|
```sh
|
|
./victoria-logs -syslog.listenAddr.tcp=:514 -syslog.compressMethod.tcp=gzip
|
|
```
|
|
|
|
## Multitenancy
|
|
|
|
By default, the ingested logs are stored in the `(AccountID=0, ProjectID=0)` [tenant](https://docs.victoriametrics.com/victorialogs/#multitenancy).
|
|
If you need storing logs in other tenant, then specify the needed tenant via `-syslog.tenantID.tcp` or `-syslog.tenantID.udp` command-line flags
|
|
depending on whether TCP or UDP ports are listened for syslog messages.
|
|
For example, the following command starts VictoriaLogs, which writes syslog messages received at TCP port 514, to `(AccountID=12, ProjectID=34)` tenant:
|
|
|
|
```sh
|
|
./victoria-logs -syslog.listenAddr.tcp=:514 -syslog.tenantID.tcp=12:34
|
|
```
|
|
|
|
## Stream fields
|
|
|
|
VictoriaLogs uses `(hostname, app_name, proc_id)` fields as labels for [log streams](https://docs.victoriametrics.com/victorialogs/keyconcepts/#stream-fields) by default.
|
|
It is possible setting other set of labels via `-syslog.streamFields.tcp` and `-syslog.streamFields.udp` command-line flags
|
|
for logs insted via the corresponding `-syslog.listenAddr.tcp` and `-syslog.listenAddr.dup` addresses.
|
|
For example, the following command starts VictoriaLogs, which uses `(hostname, app_name)` fields as log stream labels
|
|
for logs received at TCP port 514:
|
|
|
|
```sh
|
|
./victoria-logs -syslog.listenAddr.tcp=:514 -syslog.streamFields.tcp='["hostname","app_name"]'
|
|
```
|
|
|
|
## Dropping fields
|
|
|
|
VictoriaLogs supports `-syslog.ignoreFields.tcp` and `-syslog.ignoreFields.udp` command-line flags for skipping
|
|
the given [log fields](https://docs.victoriametrics.com/victorialogs/keyconcepts/#data-model) during inestion
|
|
of Syslog logs into `-syslog.listenAddr.tcp` and `-syslog.listenAddr.udp` addresses.
|
|
For example, the following command starts VictoriaLogs, which drops `proc_id` and `msg_id` fields from logs received at TCP port 514:
|
|
|
|
```sh
|
|
./victoria-logs -syslog.listenAddr.tcp=:514 -syslog.ignoreFields.tcp='["prod_id","msg_id"]'
|
|
```
|
|
|
|
## Adding extra fields
|
|
|
|
VictoriaLogs supports -`syslog.extraFields.tcp` and `-syslog.extraFields.udp` command-line flags for adding
|
|
the given [log fields](https://docs.victoriametrics.com/victorialogs/keyconcepts/#data-model) during data ingestion
|
|
of Syslog logs into `-syslog.listenAddr.tcp` and `-syslog.listenAddr.udp` addresses.
|
|
For example, the following command starts VictoriaLogs, which adds `source=foo` and `abc=def` fields to logs received at TCP port 514:
|
|
|
|
```sh
|
|
./victoria-logs -syslog.listenAddr.tcp=:514 -syslog.extraFields.tcp='{"source":"foo","abc":"def"}'
|
|
```
|
|
|
|
## Multiple configs
|
|
|
|
VictoriaLogs can accept syslog messages via multiple TCP and UDP ports with individual configurations for [log timestamps](#log-timestamps), [compression](#compression), [security](#security)
|
|
and [multitenancy](#multitenancy). Specify multiple command-line flags for this. For example, the following command starts VictoriaLogs,
|
|
which accepts gzip-compressed syslog messages via TCP port 514 at localhost interface and stores them to [tenant](https://docs.victoriametrics.com/victorialogs/#multitenancy) `123:0`,
|
|
plus it accepts TLS-encrypted syslog messages via TCP port 6514 and stores them to [tenant](https://docs.victoriametrics.com/victorialogs/#multitenancy) `567:0`:
|
|
|
|
```sh
|
|
./victoria-logs \
|
|
-syslog.listenAddr.tcp=localhost:514 -syslog.tenantID.tcp=123:0 -syslog.compressMethod.tcp=gzip -syslog.tls=false -syslog.tlsKeyFile='' -syslog.tlsCertFile='' \
|
|
-syslog.listenAddr.tcp=:6514 -syslog.tenantID.tcp=567:0 -syslog.compressMethod.tcp=none -syslog.tls=true -syslog.tlsKeyFile=/path/to/tls/key -syslog.tlsCertFile=/path/to/tls/cert
|
|
```
|
|
|
|
## Rsyslog
|
|
|
|
1. Run VictoriaLogs with `-syslog.listenAddr.tcp=:29514` command-line flag.
|
|
1. Put the following line to [rsyslog](https://www.rsyslog.com/) config (this config is usually located at `/etc/rsyslog.conf`):
|
|
```
|
|
*.* @@victoria-logs-server:29514
|
|
```
|
|
Where `victoria-logs-server` is the hostname where VictoriaLogs runs. See [these docs](https://www.rsyslog.com/sending-messages-to-a-remote-syslog-server/)
|
|
for more details.
|
|
|
|
## Syslog-ng
|
|
|
|
1. Run VictoriaLogs with `-syslog.listenAddr.tcp=:29514` command-line flag.
|
|
1. Put the following line to [syslog-ng](https://www.syslog-ng.com/) config:
|
|
```
|
|
destination d_remote {
|
|
tcp("victoria-logs-server" port(29514));
|
|
};
|
|
```
|
|
Where `victoria-logs-server` is the hostname where VictoriaLogs runs.
|
|
See [these docs](https://support.oneidentity.com/technical-documents/doc/syslog-ng-open-source-edition/3.19/administration-guide/29#TOPIC-1094570) for details.
|