mirror of
https://github.com/uhi22/pyPLC.git
synced 2024-11-20 01:13:58 +00:00
tests: fixes for testsuite and state machines. 16 of 16 fault injection tests are PASS now.
This commit is contained in:
parent
ccd7cb4e4e
commit
08af8306c6
4 changed files with 26 additions and 8 deletions
|
@ -24,6 +24,7 @@ CONNLEVEL_15_SLAC_ONGOING = 15
|
|||
CONNLEVEL_10_ONE_MODEM_FOUND = 10
|
||||
CONNLEVEL_5_ETH_LINK_PRESENT = 5
|
||||
|
||||
CONNMGR_CYCLES_PER_SECOND = 33 # 33 cycles for one second, is 30ms call cycle
|
||||
CONNMGR_TIMER_MAX = (5*33) # 5 seconds until an OkReport is forgotten.
|
||||
CONNMGR_TIMER_MAX_10s = (10*33) # 10 seconds until an OkReport is forgotten.
|
||||
CONNMGR_TIMER_MAX_15s = (15*33) # 15 seconds until an OkReport is forgotten.
|
||||
|
@ -133,8 +134,10 @@ class connMgr():
|
|||
def TcpOk(self):
|
||||
self.timerTCP = CONNMGR_TIMER_MAX_10s
|
||||
|
||||
def ApplOk(self):
|
||||
self.timerAppl = CONNMGR_TIMER_MAX_10s
|
||||
def ApplOk(self, time_in_seconds=10):
|
||||
# The application confirmed to have communication. It can decide, based on its state,
|
||||
# how long the confirmation shall hold. Default is ten seconds.
|
||||
self.timerAppl = time_in_seconds * CONNMGR_CYCLES_PER_SECOND
|
||||
|
||||
|
||||
def testCallbackAddToTrace(s):
|
||||
|
|
10
fsmEvse.py
10
fsmEvse.py
|
@ -150,7 +150,11 @@ class fsmEvse():
|
|||
self.enterState(stateWaitForFlexibleRequest) # todo: not clear, what is specified in DIN
|
||||
if (strConverterResult.find("CableCheckReq")>0):
|
||||
# todo: check the request content, and fill response parameters
|
||||
# todo: make a real cable check, and while it is ongoing, send "Ongoing".
|
||||
msg = addV2GTPHeader(exiEncode("EDf")) # EDf for Encode, Din, CableCheckResponse
|
||||
if (testsuite_faultinjection_is_triggered(TC_EVSE_ResponseCode_Failed_for_CableCheckRes)):
|
||||
# send a CableCheckResponse with Responsecode Failed
|
||||
msg = addV2GTPHeader("809a0125e6cecc5020804080000400")
|
||||
self.addToTrace("responding " + prettyHexMessage(msg))
|
||||
self.publishStatus("CableCheck")
|
||||
if (not testsuite_faultinjection_is_triggered(TC_EVSE_Timeout_during_CableCheck)):
|
||||
|
@ -181,6 +185,9 @@ class fsmEvse():
|
|||
if (testsuite_faultinjection_is_triggered(TC_EVSE_Shutdown_during_PreCharge)):
|
||||
# send a PreChargeResponse with StatusCode EVSE_Shutdown, to simulate a user-triggered session stop
|
||||
msg = addV2GTPHeader("809a02180189551e24fc9e9160004100008182800000")
|
||||
if (testsuite_faultinjection_is_triggered(TC_EVSE_ResponseCode_Failed_for_PreChargeRes)):
|
||||
# send a PreChargeResponse with ResponseCode Failed
|
||||
msg = addV2GTPHeader("809a0125e6cecc516080408000008284de880800")
|
||||
self.addToTrace("responding " + prettyHexMessage(msg))
|
||||
self.publishStatus("PreCharging " + strPresentVoltage)
|
||||
if (not testsuite_faultinjection_is_triggered(TC_EVSE_Timeout_during_PreCharge)):
|
||||
|
@ -220,6 +227,9 @@ class fsmEvse():
|
|||
if (testsuite_faultinjection_is_triggered(TC_EVSE_Shutdown_during_CurrentDemand)):
|
||||
# send a CurrentDemandResponse with StatusCode EVSE_Shutdown, to simulate a user stop request
|
||||
msg = addV2GTPHeader("809a0125e15c2cd0e000410000018280001818000000040a1b648030300002038486580800")
|
||||
if (testsuite_faultinjection_is_triggered(TC_EVSE_ResponseCode_Failed_for_CurrentDemandRes)):
|
||||
# send a CurrentDemandResponse with ResponseCode Failed
|
||||
msg = addV2GTPHeader("809a0125e6cecc50e0804080000082867dc8081818000000040a1b64802030882702038486580800")
|
||||
self.addToTrace("responding " + prettyHexMessage(msg))
|
||||
self.publishStatus("CurrentDemand")
|
||||
if (not testsuite_faultinjection_is_triggered(TC_EVSE_Timeout_during_CurrentDemand)):
|
||||
|
|
|
@ -158,6 +158,10 @@ class fsmPev():
|
|||
msg = addV2GTPHeader(self.exiEncode("EDF_"+self.sessionId + "_" + soc)) # EDF for Encode, Din, CableCheckReq
|
||||
self.addToTrace("responding " + prettyHexMessage(msg))
|
||||
self.Tcp.transmit(msg)
|
||||
# Since the response to the CableCheckRequest may need longer, inform the connection manager to be patient.
|
||||
# This makes sure, that the timeout of the state machine comes before the timeout of the connectionManager, so
|
||||
# that we enter the safe shutdown sequence as intended.
|
||||
self.connMgr.ApplOk(31)
|
||||
|
||||
|
||||
def sendCurrentDemandReq(self):
|
||||
|
@ -485,6 +489,7 @@ class fsmPev():
|
|||
msg = addV2GTPHeader(self.exiEncode("EDG_"+self.sessionId+"_"+str(soc)+"_"+str(EVTargetVoltage))) # EDG for Encode, Din, PreChargeReq
|
||||
self.addToTrace("responding " + prettyHexMessage(msg))
|
||||
self.Tcp.transmit(msg)
|
||||
self.connMgr.ApplOk(31) # PreChargeResponse may need longer. Inform the connection manager to be patient.
|
||||
self.enterState(stateWaitForPreChargeResponse)
|
||||
else:
|
||||
if (self.numberOfCableCheckReq>60): # approx 60s should be sufficient for cable check. The ISO allows up to 55s reaction time and 60s timeout for "ongoing".
|
||||
|
|
|
@ -19,11 +19,11 @@ from configmodule import getConfigValue, getConfigValueBool
|
|||
# The list of test cases. Each must have a unique test case ID.
|
||||
TC_NOTHING_TO_TEST = 0
|
||||
TC_EVSE_ResponseCode_SequenceError_for_SessionSetup = 1
|
||||
TC_EVSE_ResponseCode_SequenceError_for_ServiceDiscoveryRes = 2
|
||||
TC_EVSE_ResponseCode_SequenceError_for_ServicePaymentSelectionRes = 3
|
||||
TC_EVSE_ResponseCode_SequenceError_for_ContractAuthenticationRes = 4
|
||||
TC_EVSE_ResponseCode_ServiceSelectionInvalid_for_ChargeParameterDiscovery = 5
|
||||
TC_EVSE_ResponseCode_Failed_for_CableCheckRes = 6
|
||||
TC_EVSE_ResponseCode_Failed_for_CableCheckRes = 2
|
||||
TC_EVSE_ResponseCode_SequenceError_for_ServiceDiscoveryRes = 3
|
||||
TC_EVSE_ResponseCode_SequenceError_for_ServicePaymentSelectionRes = 4
|
||||
TC_EVSE_ResponseCode_SequenceError_for_ContractAuthenticationRes = 5
|
||||
TC_EVSE_ResponseCode_ServiceSelectionInvalid_for_ChargeParameterDiscovery = 6
|
||||
TC_EVSE_ResponseCode_Failed_for_PreChargeRes = 7
|
||||
TC_EVSE_ResponseCode_Failed_for_PowerDeliveryRes = 8
|
||||
TC_EVSE_ResponseCode_Failed_for_CurrentDemandRes = 9
|
||||
|
@ -162,7 +162,7 @@ def testsuite_choose_testcase():
|
|||
testsuite_TcTitle = "ServiceSelectionInvalid in ChargeParameterDiscoveryshall lead to SafeShutdown"
|
||||
|
||||
if (testsuite_testcase_number == TC_EVSE_ResponseCode_Failed_for_CableCheckRes):
|
||||
testsuite_delayCycles=2 # after two ok cycles, we inject the fault in the third cycle
|
||||
testsuite_delayCycles=0 # immediately in the first message
|
||||
testsuite_expectedResult = "TSRS_SafeShutdownFinished"
|
||||
testsuite_TcTitle = "Failed in CableCheckRes shall lead to SafeShutdown"
|
||||
|
||||
|
|
Loading…