mirror of
https://github.com/uhi22/pyPLC.git
synced 2024-11-20 01:13:58 +00:00
docu: Notes for TPlink TL-PA4010P v2.3
This commit is contained in:
parent
da84e8b2ef
commit
18f8ab7aef
1 changed files with 7 additions and 1 deletions
|
@ -36,7 +36,7 @@ The open-plc-utils report the version MAC-QCA7500-2.8.0.30-01-20190707-CS.
|
||||||
Contra:
|
Contra:
|
||||||
- Even with the modified configuration for pev (according to https://openinverter.org/forum/viewtopic.php?p=55120#p55120), the QCA7500 does not send SLAC parameter requests. This means: Cannot be used as pev.
|
- Even with the modified configuration for pev (according to https://openinverter.org/forum/viewtopic.php?p=55120#p55120), the QCA7500 does not send SLAC parameter requests. This means: Cannot be used as pev.
|
||||||
|
|
||||||
### TPlink TL-PA4010P
|
### TPlink TL-PA4010P v5.0
|
||||||
This adaptor was suggested by https://openinverter.org/forum/viewtopic.php?p=37085#p37085 and there,
|
This adaptor was suggested by https://openinverter.org/forum/viewtopic.php?p=37085#p37085 and there,
|
||||||
successfully used to establish a communication to the CCS charger.
|
successfully used to establish a communication to the CCS charger.
|
||||||
|
|
||||||
|
@ -67,6 +67,12 @@ How to modify:
|
||||||
- connect cables to supply the device. Works with 12V, also works with 5V from an USB power bank.
|
- connect cables to supply the device. Works with 12V, also works with 5V from an USB power bank.
|
||||||
- connect cables and circuit (1nF and 150ohms in series) for connecting to the pilot line.
|
- connect cables and circuit (1nF and 150ohms in series) for connecting to the pilot line.
|
||||||
|
|
||||||
|
#### TPlink TL-PA4010P v2.3
|
||||||
|
![image](https://github.com/user-attachments/assets/c98d100c-f7fc-4e41-a183-1b5eeebd43fa)
|
||||||
|
![image](https://github.com/user-attachments/assets/6fef8096-4373-42d9-9688-7d284f587940)
|
||||||
|
|
||||||
|
Confirmed to be working as EVSE (needs patching via open-plc-utils) and supplied with 5V.
|
||||||
|
|
||||||
## Controller for the PEV
|
## Controller for the PEV
|
||||||
|
|
||||||
Besides the homeplug modem, there are additional parts necessary for a vehicle to perform CCS charging. Two of these are: 1. The inlet voltage measurement. 2. The control of CP state and relays.
|