mirror of
https://github.com/uhi22/pyPLC.git
synced 2024-11-20 01:13:58 +00:00
docu: added charger test results and todos
This commit is contained in:
parent
e9466601be
commit
3620b7c4f9
2 changed files with 20 additions and 2 deletions
|
@ -72,6 +72,11 @@ Test results of version v0.4-7-g7cea8b5 (2022-12-21)
|
||||||
- [ ] DIN SessionStop: No response
|
- [ ] DIN SessionStop: No response
|
||||||
- [x] Inlet voltage measurement (shows 500V during cable check, and 230V during precharge)
|
- [x] Inlet voltage measurement (shows 500V during cable check, and 230V during precharge)
|
||||||
|
|
||||||
|
## Circontrol
|
||||||
|
|
||||||
|
First test negative, see https://openinverter.org/forum/viewtopic.php?p=56268#p56268.
|
||||||
|
The SLAC works, but after SetKey we do not see the chargers modem.
|
||||||
|
|
||||||
## Compleo Cito BM 500
|
## Compleo Cito BM 500
|
||||||
|
|
||||||
Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/EDEKA-Ingolstaedter-Strasse-114/62619/
|
Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/EDEKA-Ingolstaedter-Strasse-114/62619/
|
||||||
|
@ -149,6 +154,14 @@ Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolst
|
||||||
|
|
||||||
Test results tbd
|
Test results tbd
|
||||||
|
|
||||||
|
## Siemens
|
||||||
|
|
||||||
|
Charging works, see https://openinverter.org/forum/viewtopic.php?p=56478#p56478
|
||||||
|
|
||||||
|
## Tesla Supercharger V2
|
||||||
|
|
||||||
|
Charging works, see https://openinverter.org/forum/viewtopic.php?p=56478#p56478
|
||||||
|
|
||||||
## Tesla Supercharger V3
|
## Tesla Supercharger V3
|
||||||
|
|
||||||
Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/Supercharger-Car-Wash-Ruppertswies-4/69557/
|
Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/Supercharger-Car-Wash-Ruppertswies-4/69557/
|
||||||
|
@ -173,3 +186,6 @@ Test results of version v0.5-12-g23b1384, on 2023-03-02
|
||||||
- [ ] DIN WeldingDetection
|
- [ ] DIN WeldingDetection
|
||||||
- [ ] DIN SessionStop
|
- [ ] DIN SessionStop
|
||||||
|
|
||||||
|
## Tritium 75kW
|
||||||
|
|
||||||
|
Charging works, see https://openinverter.org/forum/viewtopic.php?p=56268#p56268
|
||||||
|
|
|
@ -28,9 +28,11 @@
|
||||||
- [ ] Still fixed addresses (MAC, IP?) used on windows, add auto-detection or configuration
|
- [ ] Still fixed addresses (MAC, IP?) used on windows, add auto-detection or configuration
|
||||||
- [x] configurable interface name and simplify address determination (see https://openinverter.org/forum/viewtopic.php?p=54659#p54659)
|
- [x] configurable interface name and simplify address determination (see https://openinverter.org/forum/viewtopic.php?p=54659#p54659)
|
||||||
- [x] in the SessionSetupRequest we need to set the EVCCID with the MAC of the car. At the moment this is not implemented, need to update in the OpenV2Gx the function encodeSessionSetupRequest(), also the fsmPev.py, and provide the MAC as command line parameter from the python to the OpenV2Gx. (see https://openinverter.org/forum/viewtopic.php?p=54667#p54667)
|
- [x] in the SessionSetupRequest we need to set the EVCCID with the MAC of the car. At the moment this is not implemented, need to update in the OpenV2Gx the function encodeSessionSetupRequest(), also the fsmPev.py, and provide the MAC as command line parameter from the python to the OpenV2Gx. (see https://openinverter.org/forum/viewtopic.php?p=54667#p54667)
|
||||||
- [ ] integrate celeron55s hardware interface, use config options for this.
|
- [x] integrate celeron55s hardware interface, use config options for this.
|
||||||
- [ ] configurable serial interface and baud rate
|
- [x] configurable serial interface and baud rate
|
||||||
- [ ] add plausibilization between EVSEPresentVoltage and physicalVoltage before closing contactors (configurable)
|
- [ ] add plausibilization between EVSEPresentVoltage and physicalVoltage before closing contactors (configurable)
|
||||||
- [ ] find out how a normal end of charging session works (Stopped on charger, stopped on car)
|
- [ ] find out how a normal end of charging session works (Stopped on charger, stopped on car)
|
||||||
- [ ] PevMode: Evaluate the error code reported by the charger, and enter into state stateUnrecoverableError.
|
- [ ] PevMode: Evaluate the error code reported by the charger, and enter into state stateUnrecoverableError.
|
||||||
|
- [ ] Configurable pathes in sharter.sh
|
||||||
|
- [ ] A timeout during PreCharging shall run into the safe shutdown sequence. Same for CableCheck.
|
||||||
- [ ] (and some more)
|
- [ ] (and some more)
|
||||||
|
|
Loading…
Reference in a new issue