From 591a2a2190558390ba9de77426da5d12b781d29d Mon Sep 17 00:00:00 2001 From: uhi22 Date: Wed, 30 Nov 2022 18:56:35 +0100 Subject: [PATCH] added charger_test_results.md --- doc/charger_test_results.md | 77 +++++++++++++++++++++++++++++++++++++ 1 file changed, 77 insertions(+) create mode 100644 doc/charger_test_results.md diff --git a/doc/charger_test_results.md b/doc/charger_test_results.md new file mode 100644 index 0000000..c1082c8 --- /dev/null +++ b/doc/charger_test_results.md @@ -0,0 +1,77 @@ +# Test Results on different Real-World Chargers + +## ABB Terra 53 Triple Charger + +Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolstadt/hagebaumarkt-Siemensstrasse-1/48209/ + +Test results of version v0.2 +- [x] SLAC +- [x] SDP +- [x] TCP connection +- [x] EXI + - [x] DIN SupportedApplicationProtocol + - [x] DIN SessionSetup + - [x] DIN ServiceDiscovery + - [x] DIN ChargeParameterDiscovery + - [ ] DIN CableCheck + - [ ] DIN PreCharge + - [ ] DIN PowerDelivery, CurrentDemand + +## ABB Terra HPC + +Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/Total-Tankstelle-Ruppertswies-6/63794/ + +Test results tbd + +## Alpitronic HPC HYC300 + +Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolstadt/Dehner-Garten-Center-Degenhartstrasse-Degenhartstrasse-2/71112/ + +Test results of version v0.2 +- [x] SLAC +- [x] SDP +- [ ] TCP connection +- [ ] EXI + - [ ] DIN SupportedApplicationProtocol + - [ ] DIN SessionSetup + - [ ] DIN ServiceDiscovery + - [ ] DIN ChargeParameterDiscovery + - [ ] DIN CableCheck + - [ ] DIN PreCharge + - [ ] DIN PowerDelivery, CurrentDemand + +## Compleo Cito BM 500 + +Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/EDEKA-Ingolstaedter-Strasse-114/62619/ + +Test results tbd + +## Efacec QC45 Triple Charger + +Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Hepberg/Koeschinger-Forst-West-A9/15982/ + +Test results tbd + +## Efacec HPC Efapower Kiosk HV175 + +Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Neufahrn-bei-Freising/Fuerholzen-West-A9/22771/ + +Test results tbd + +## Ionity Tritium Veefil-PK + +Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Hepberg/IONITY-Koeschinger-Forst-Ost-A9/37875/ + +Test results tbd + +## Porsche + +Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolstadt/Audi-Forum-Ettinger-Strasse/7970/ + +Test results tbd + +## Tesla Supercharger V3 + +Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/Supercharger-Car-Wash-Ruppertswies-4/69557/ + +Test results tbd