feature: EVSE stimulates a set of testcases for the PEV.

This commit is contained in:
uhi22 2023-05-14 00:22:26 +02:00
parent 3620b7c4f9
commit 6c1703b1a9
5 changed files with 57 additions and 11 deletions

View file

@ -50,6 +50,15 @@ class fsmEvse():
if (strConverterResult.find("ProtocolNamespace=urn:din")>0):
# todo: of course we should care for schemaID and prio also here
self.addToTrace("Detected DIN")
# TESTSUITE: When the EVSE received the Handshake, it selects a new test case.
testsuite_choose_testcase()
strTestcase = "TC" + str(testsuite_getTcNumber()) + " "
msg = bytearray(20)
for i in range(0, 20):
msg[i] = ord(strTestcase[i])
self.Tcp.transmit(msg) # Announce the test case number to the pev, so that we see it in the cars log.
# It's not sure that this is a good idea, maybe the unexpected data in the TCP
# confuses the car.
# Eh for encode handshake, SupportedApplicationProtocolResponse
msg = addV2GTPHeader(exiEncode("Eh"))
self.addToTrace("responding " + prettyHexMessage(msg))
@ -135,6 +144,7 @@ class fsmEvse():
msg = addV2GTPHeader(exiEncode("EDf")) # EDf for Encode, Din, CableCheckResponse
self.addToTrace("responding " + prettyHexMessage(msg))
self.publishStatus("CableCheck")
if (not testsuite_faultinjection_is_triggered(TC_EVSE_Timeout_during_CableCheck)):
self.Tcp.transmit(msg)
self.enterState(stateWaitForFlexibleRequest) # todo: not clear, what is specified in DIN
if (strConverterResult.find("PreChargeReq")>0):
@ -164,6 +174,7 @@ class fsmEvse():
msg = addV2GTPHeader("809a02180189551e24fc9e9160004100008182800000")
self.addToTrace("responding " + prettyHexMessage(msg))
self.publishStatus("PreCharging " + strPresentVoltage)
if (not testsuite_faultinjection_is_triggered(TC_EVSE_Timeout_during_PreCharge)):
self.Tcp.transmit(msg)
self.enterState(stateWaitForFlexibleRequest) # todo: not clear, what is specified in DIN
if (strConverterResult.find("ContractAuthenticationReq")>0):
@ -194,8 +205,12 @@ class fsmEvse():
if (testsuite_faultinjection_is_triggered(TC_EVSE_Malfunction_during_CurrentDemand)):
# send a CurrentDemandResponse with StatusCode EVSE_Malfunction, to simulate e.g. a voltage overshoot
msg = addV2GTPHeader("809a02203fa9e71c31bc920100821b430b933b4b7339032b93937b908e08043000081828440201818000040060a11c06030306402038441380")
if (testsuite_faultinjection_is_triggered(TC_EVSE_Shutdown_during_CurrentDemand)):
# send a CurrentDemandResponse with StatusCode EVSE_Shutdown, to simulate a user stop request
msg = addV2GTPHeader("809a0125e15c2cd0e000410000018280001818000000040a1b648030300002038486580800")
self.addToTrace("responding " + prettyHexMessage(msg))
self.publishStatus("CurrentDemand")
if (not testsuite_faultinjection_is_triggered(TC_EVSE_Timeout_during_CurrentDemand)):
self.Tcp.transmit(msg)
self.enterState(stateWaitForFlexibleRequest) # todo: not clear, what is specified in DIN
if (strConverterResult.find("WeldingDetectionReq")>0):

View file

@ -233,6 +233,10 @@ class fsmPev():
def stateFunctionWaitForSupportedApplicationProtocolResponse(self):
if (len(self.rxData)>0):
self.addToTrace("In state WaitForSupportedApplicationProtocolResponse, received " + prettyHexMessage(self.rxData))
if ((self.rxData[0]!=0x01) or (self.rxData[1]!=0xFE)):
# it is no EXI data. Print it to log, it could be a TESTSUITE notification.
self.addToTrace("TESTSUITE notification. Seems we are running a test case. TTTTTTTTTTTTTTTTTTTTTTT")
return
exidata = removeV2GTPHeader(self.rxData)
self.rxData = []
strConverterResult = self.exiDecode(exidata, "Dh") # Decode Handshake-response

View file

@ -11,19 +11,25 @@
# The list of test cases. Each must have a unique test case ID.
TC_NOTHING_TO_TEST = 0
TC_EVSE_Shutdown_during_PreCharge = 1000
TC_EVSE_Shutdown_during_CurrentDemand = 2000
TC_EVSE_Malfunction_during_CurrentDemand = 2001
# Here we configure, which test case should fire, and after which number of calls:
testsuite_testcase_number = TC_EVSE_Malfunction_during_CurrentDemand
testsuite_delayCycles = 200
TC_EVSE_Timeout_during_CableCheck = 1
TC_EVSE_Timeout_during_PreCharge = 2
TC_EVSE_Shutdown_during_PreCharge = 3
TC_EVSE_Shutdown_during_CurrentDemand = 4
TC_EVSE_Malfunction_during_CurrentDemand = 5
TC_EVSE_Timeout_during_CurrentDemand = 6
TC_EVSE_LastTest = 7
# variables
testsuite_testcase_number = 0
testsuite_delayCycles = 0
# Counter variable for delaying the trigger
testsuite_counter = 0
def testsuite_getTcNumber():
return testsuite_testcase_number
def testsuite_faultinjection_is_triggered(context):
global testsuite_counter, testsuite_testcase_number, testsuite_delayCycles
isTestcaseFired = False
@ -35,6 +41,17 @@ def testsuite_faultinjection_is_triggered(context):
return isTestcaseFired
def testsuite_choose_testcase():
global testsuite_counter, testsuite_testcase_number, testsuite_delayCycles
if (testsuite_testcase_number<TC_EVSE_LastTest):
testsuite_testcase_number+=1
print("[TESTSUITE] Setting up test case " + str(testsuite_testcase_number) + " TTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTTT")
testsuite_counter = 0
testsuite_delayCycles = 5
if (testsuite_testcase_number == TC_EVSE_Timeout_during_CableCheck):
testsuite_delayCycles=0 # immediately timeout
if __name__ == "__main__":
print("Testing the mytestsuite")
print("nothing to do")

View file

@ -12,6 +12,7 @@ import pyPlcWorker
from pyPlcModes import *
import sys # for argv
from configmodule import getConfigValue, getConfigValueBool
from mytestsuite import *
startTime_ms = round(time.time()*1000)
@ -113,6 +114,11 @@ lblUInlet.pack()
lblEVSEPresentVoltage = tk.Label(root, text="(EVSEPresentVoltage)")
lblEVSEPresentVoltage.config(font=('Helvetica bold', 16))
lblEVSEPresentVoltage.pack()
if (myMode == C_EVSE_MODE):
lblTestcase = tk.Label(root, text="(test case)")
lblTestcase.pack()
lblMode = tk.Label(root, text="(mode)")
lblMode.pack()
@ -133,6 +139,9 @@ while lastKey!="x":
# print(str(nMainloops) + " " + str(nKeystrokes)) # show something in the console window
root.update()
worker.mainfunction()
if (myMode == C_EVSE_MODE):
lblTestcase['text']= "Testcase " + str(testsuite_getTcNumber())
del(worker)
#---------------------------------------------------------------

View file

@ -79,6 +79,7 @@ class pyPlcWorker():
self.hp.mainfunction() # call the lower-level workers
self.hardwareInterface.mainfunction()
if (self.mode == C_EVSE_MODE):
if (self.nMainFunctionCalls>8*33): # ugly. Wait with EVSE high level handling, until the modem restarted.
self.evse.mainfunction() # call the evse state machine
if (self.mode == C_PEV_MODE):
self.pev.mainfunction() # call the pev state machine