docu: Foccci 5.1 transmit amplitude and receive sensitivity
This commit is contained in:
parent
fcbddeb59d
commit
74a6db3707
1 changed files with 20 additions and 0 deletions
|
@ -44,3 +44,23 @@ This would be 9dB between transmitter output and receiver input.
|
||||||
4Vpp. Each output (TX+ and TX-) sit at ~1.6V statically, and move 1V up and 1V down. So the differential voltage
|
4Vpp. Each output (TX+ and TX-) sit at ~1.6V statically, and move 1V up and 1V down. So the differential voltage
|
||||||
reaches from -2V to +2V, which is 4Vpp.
|
reaches from -2V to +2V, which is 4Vpp.
|
||||||
|
|
||||||
|
8. Foccci 5.1 transmit level
|
||||||
|
|
||||||
|
with 120ohm termination
|
||||||
|
|
||||||
|
270mVpp
|
||||||
|
|
||||||
|
9. Foccci 5.1 receive limit test
|
||||||
|
|
||||||
|
- Foccci sees the EVSE, starting to become instable, if 400mVpp -36dB. This is 400mVpp / 64 = 6mVpp.
|
||||||
|
- Foccci sees single messages, if 400mVpp -42dB. This is 3mV.
|
||||||
|
- Foccci does not see the EVSE (modem goes to sleep) if 400mVpp -44dB. This is 400mVpp/158 = 2.5mVpp.
|
||||||
|
|
||||||
|
|
||||||
|
# Attenuation calculator
|
||||||
|
|
||||||
|
https://www.digikey.de/de/resources/conversion-calculators/conversion-calculator-attenuator
|
||||||
|
|
||||||
|
* -6dB is half voltage
|
||||||
|
* -12dB is quater voltage
|
||||||
|
* -20dB is tenth voltage
|
||||||
|
|