docu: new checkpoint 790, User stops at the charger side
This commit is contained in:
parent
b99c78d678
commit
a416fbe69e
1 changed files with 1 additions and 0 deletions
|
@ -373,6 +373,7 @@ target current.
|
|||
* Checkpoint705: The charger confirms with CurrentDemandResponse. This contains the measured voltage, measured current, and flags which show which limitation
|
||||
is active (current limitation, voltage limitation, power limitation).
|
||||
* Checkpoint710: The CurrentDemandRequest/CurrentDemandResponse are repeated during the charging.
|
||||
* Checkpoint790: When the user stops the charging session on the charger, the charger sends DC_EVSEStatus.EVSEStatusCode = 2 "EVSE_Shutdown" in the CurrentDemandResponse. (Observed on Compleo, see https://github.com/uhi22/Ioniq28Investigations/blob/main/CCM_ChargeControlModule_PLC_CCS/ccm_spi_ioniq_compleo_full_charge_sequence_ended_on_charger.txt.pcap.decoded.txt)
|
||||
* Checkpoint800: When the end of charging is decided (battery full or user wish), the car sends PowerDelivery(Stop)Request.
|
||||
* Checkpoint805: The charger confirms with PowerDeliveryResponse.
|
||||
* Checkpoint806: The car receives the PowerDeliveryResponse.
|
||||
|
|