mirror of
https://github.com/uhi22/pyPLC.git
synced 2024-11-20 01:13:58 +00:00
rolled back the waiting during EVSE_NotReady in ChargeParameterDiscovery
This commit is contained in:
parent
729c3791eb
commit
bcfa89f854
1 changed files with 4 additions and 3 deletions
|
@ -430,10 +430,11 @@ class fsmPev():
|
|||
# (A) The charger needs more time to show the charge parameters. It does not say "EVSEProcessing": "Finished".
|
||||
# (B) The charger finished to tell the charge parameters, but still needs more time for internal purposes.
|
||||
# It says "EVSEProcessing": "Finished", but also "EVSEStatusCode_text": "EVSE_NotReady". Observed and discussed
|
||||
# here: https://openinverter.org/forum/viewtopic.php?p=58239#p58239
|
||||
# here: https://openinverter.org/forum/viewtopic.php?p=58239#p58239.
|
||||
# Update: This seems to be a normal case for Compleo, and NO reason to wait. So we go to the next step (cable check).
|
||||
# (C) The charger is really finished and able to continue with the next step (cable check).
|
||||
if ((strEVSEProcessing == "Finished") and (strEVSEStatusCode_text == "EVSE_Ready")) :
|
||||
# Case C
|
||||
if ((strEVSEProcessing == "Finished")) :
|
||||
# Case B and C
|
||||
self.publishStatus("ChargeParams discovered")
|
||||
self.addToTrace("Checkpoint550: ChargeParams are discovered. Will change to state C.")
|
||||
#Report charger paramters
|
||||
|
|
Loading…