From c42afc7a6ba2138ee7fe4a568a37dfb043b69a79 Mon Sep 17 00:00:00 2001 From: uhi22 Date: Mon, 11 Dec 2023 19:19:15 +0100 Subject: [PATCH] docu: connector unlock added to end of charging session --- readme.md | 1 + 1 file changed, 1 insertion(+) diff --git a/readme.md b/readme.md index d35637d..6429410 100644 --- a/readme.md +++ b/readme.md @@ -418,6 +418,7 @@ is active (current limitation, voltage limitation, power limitation). * [13.838] WeldingDetectionRes.EVSEPresentVoltage = 109V * [13.918] Again WeldingDetectionReq * [14.928] WeldingDetectionRes.EVSEPresentVoltage = 65V +* [15.000] The car sees that the voltage is below dangerous level and unlocks the connector. (Better here than after SessionStopReq, because if the charger crashes and does not send a SessionStop, we should not been locked forever.) * [15.178] SessionStopReq * [15.688] SessionStopRes