pyPLC/results/2022-11-09_still_FAILED_ChargingSystemIncompatibility.txt
2022-11-09 19:12:32 +01:00

177 lines
No EOL
6.8 KiB
Text

C:\UwesTechnik\pyPLC>python pyPlc.py E
starting in EVSE_MODE
initializing pyPlcWorker
Interfaces:
\Device\NPF_{CF245078-25B1-4487-AE2A-1763158ACD5F}
\Device\NPF_{7105741E-F8FC-46AD-9BCD-95F7CDCC76B0}
\Device\NPF_{F2DFA311-B486-461A-A3F4-0DBA998BF9F9}
\Device\NPF_{0DFD428E-B132-4188-8EBC-38C13B0C89CF}
\Device\NPF_{E4B8176C-8516-4D48-88BC-85225ABCF259}
\Device\NPF_{68936D7B-F0E7-46E7-A047-3C07A24E03B9}
\Device\NPF_{A541C45F-EDAC-4242-ABF6-B4337228BBFF}
\Device\NPF_Loopback
index match at 0 dev name=b'\\Device\\NPF_Loopback' dev.description=b'Adapter for loopback traffic capture'
index match at 1 dev name=b'\\Device\\NPF_{A541C45F-EDAC-4242-ABF6-B4337228BBFF}' dev.description=b'Microsoft Wi-Fi Direct Virtual Adapter'
index match at 2 dev name=b'\\Device\\NPF_{68936D7B-F0E7-46E7-A047-3C07A24E03B9}' dev.description=b'Microsoft Wi-Fi Direct Virtual Adapter #2'
index match at 3 dev name=b'\\Device\\NPF_{E4B8176C-8516-4D48-88BC-85225ABCF259}' dev.description=b'Broadcom NetLink (TM) Gigabit Ethernet'
This is the wanted Ethernet adaptor.
index match at 4 dev name=b'\\Device\\NPF_{0DFD428E-B132-4188-8EBC-38C13B0C89CF}' dev.description=b'Broadcom 802.11n-Netzwerkadapter'
index match at 5 dev name=b'\\Device\\NPF_{F2DFA311-B486-461A-A3F4-0DBA998BF9F9}' dev.description=b'WAN Miniport (IP)'
index match at 6 dev name=b'\\Device\\NPF_{7105741E-F8FC-46AD-9BCD-95F7CDCC76B0}' dev.description=b'WAN Miniport (IPv6)'
index match at 7 dev name=b'\\Device\\NPF_{CF245078-25B1-4487-AE2A-1763158ACD5F}' dev.description=b'WAN Miniport (Network Monitor)'
index match at 3 dev name=b'\\Device\\NPF_{E4B8176C-8516-4D48-88BC-85225ABCF259}' dev.description=b'Broadcom NetLink (TM) Gigabit Ethernet'
sniffer created at eth3
initializing fsmEvse
pyPlcTcpSocket listening on port 15118
0x6064
transmitting CM_SLAC_PARAM.CNF
0x6065
0x606a
0x606a
0x606a
0x6076
0xa14e
0x6086
0x6076
0xa14e
0x6086
0x6076
0xa14e
0x6086
0x6076
0xa14e
0x6086
0x6076
0xa14e
0x6086
0x6076
0xa14e
0x6086
0x6076
0xa14e
0x6086
0x6076
0xa14e
0x6086
0x6076
0xa14e
0x6086
0x6076
transmitting ATTEN_CHAR.IND
0xa14e
0x6086
0x606e
0x606f
0x607c
transmitting SLAC_MATCH.CNF
0x607d
V2GTP (10bytes) = 01 FE 90 00 00 00 00 02 10 00
ok, this was a valid SDP request
We are the SECC. Sending SDP response.
SDP payload (20bytes) = FE 80 00 00 00 00 00 00 E0 AD 99 AC 52 EB 85 D3 3B 0E 10 00
V2Gframe (28bytes) = 01 FE 90 01 00 00 00 14 FE 80 00 00 00 00 00 00 E0 AD 99 AC 52 EB 85 D3 3B 0E 10 00
UDP response (36bytes) = 3B 0E C3 71 00 24 00 00 01 FE 90 01 00 00 00 14 FE 80 00 00 00 00 00 00 E0 AD 99 AC 52 EB 85 D3 3B 0E 10 00
IP response (76bytes) = 60 00 00 00 00 24 11 0A FE 80 00 00 00 00 00 00 E0 AD 99 AC 52 EB 85 D3 FE 80 00 00 00 00 00 00 06 65 65 FF FE 00 64 C3 3B 0E C3 71 00 24 B3 26 01 FE 90 01 00 00 00 14 FE 80 00 00 00 00 00 00 E0 AD 99 AC 52 EB 85 D3 3B 0E 10 00
Connection from ('fe80::665:65ff:fe00:64c3', 50095, 0, 16)
In state WaitForSupportedApplicationProtocolRequest, received (42bytes) = 01 FE 80 01 00 00 00 22 80 00 DB AB 93 71 D3 23 4B 71 D1 B9 81 89 91 89 D1 91 81 89 91 D2 6B 9B 3A 23 2B 30 02 00 00 04 00 40
{
"info": "34 bytes to convert",
"error": "",
"result": "Vehicle supports 1 protocols. ProtocolEntry#1 ProtocolNamespace=urn:din:70121:2012:MsgDef Version=2.0 SchemaID=1 Priority=1 ",
"schema": "appHandshake",
"msgName": "supportedAppProtocolReq",
"debug": ""
}
Detected DIN
responding (12bytes) = 01 FE 80 01 00 00 00 04 80 40 00 40
from 0 entering 1
[SNIFFER] EXI from 50095 to 15118 (34bytes) = 80 00 DB AB 93 71 D3 23 4B 71 D1 B9 81 89 91 89 D1 91 81 89 91 D2 6B 9B 3A 23 2B 30 02 00 00 04 00 40
[SNIFFER] EXI from 15118 to 50095 (4bytes) = 80 40 00 40
[SNIFFER] EXI from 50095 to 15118 (21bytes) = 80 9A 02 00 00 00 00 00 00 00 00 11 D0 18 11 95 94 01 93 0C 00
In state stateFunctionWaitForSessionSetupRequest, received (29bytes) = 01 FE 80 01 00 00 00 15 80 9A 02 00 00 00 00 00 00 00 00 11 D0 18 11 95 94 01 93 0C 00
{
"info": "21 bytes to convert",
"error": "",
"result": "",
"schema": "DIN",
"g_errn": "0",
"msgName": "SessionSetupReq",
"EVCCID.bytesLen": "6",
"EVCCID": "0465650064c3",
"debug": "Line532"
}
responding (24bytes) = 01 FE 80 01 00 00 00 10 80 9A 02 00 40 80 C1 01 41 81 C2 11 E0 00 00 80
from 1 entering 2
[SNIFFER] EXI from 15118 to 50095 (16bytes) = 80 9A 02 00 40 80 C1 01 41 81 C2 11 E0 00 00 80
[SNIFFER] EXI from 50095 to 15118 (14bytes) = 80 9A 02 00 40 80 C1 01 41 81 C2 11 94 00
In state WaitForServiceDiscoveryRequest, received (22bytes) = 01 FE 80 01 00 00 00 0E 80 9A 02 00 40 80 C1 01 41 81 C2 11 94 00
{
"info": "14 bytes to convert",
"error": "",
"result": "",
"schema": "DIN",
"g_errn": "0",
"msgName": "ServiceDiscoveryReq",
"ServiceCategory_isUsed": "True",
"debug": "Line508"
}
responding (27bytes) = 01 FE 80 01 00 00 00 13 80 9A 02 00 40 80 C1 01 41 81 C2 11 A0 01 20 02 41 00 84
from 2 entering 3
[SNIFFER] EXI from 15118 to 50095 (19bytes) = 80 9A 02 00 40 80 C1 01 41 81 C2 11 A0 01 20 02 41 00 84
[SNIFFER] EXI from 50095 to 15118 (16bytes) = 80 9A 02 00 40 80 C1 01 41 81 C2 11 B2 00 12 80
In state WaitForServicePaymentSelectionRequest, received (24bytes) = 01 FE 80 01 00 00 00 10 80 9A 02 00 40 80 C1 01 41 81 C2 11 B2 00 12 80
{
"info": "16 bytes to convert",
"error": "",
"result": "",
"schema": "DIN",
"g_errn": "0",
"msgName": "ServicePaymentSelectionReq",
"SelectedPaymentOption": "ExternalPayment",
"SelectedService.arrayLen": "1",
"SelectedService.array": "0:1",
"debug": "Line520"
}
responding (22bytes) = 01 FE 80 01 00 00 00 0E 80 9A 02 00 40 80 C1 01 41 81 C2 11 C0 00
from 3 entering 4
[SNIFFER] EXI from 15118 to 50095 (14bytes) = 80 9A 02 00 40 80 C1 01 41 81 C2 11 C0 00
In state WaitForFlexibleRequest, received (28bytes) = 01 FE 80 01 00 00 00 14 80 9A 02 00 40 80 C1 01 41 81 C2 11 30 20 00 0A 00 00 00 00
{
"info": "20 bytes to convert",
"error": "",
"result": "",
"schema": "DIN",
"g_errn": "0",
"msgName": "PowerDeliveryReq",
"ReadyToChargeState": "0",
"ChargingProfile_isUsed": "0",
"EVPowerDeliveryParameter_isUsed": "0",
"DC_EVPowerDeliveryParameter_isUsed": "1",
"EVReady": "0",
"EVErrorCode": "10",
"EVErrorCodeText": "FAILED_ChargingSystemIncompatibility",
"EVRESSSOC": "0",
"BulkChargingComplete": "0",
"ChargingComplete": "0",
"debug": "Line472"
}
responding (26bytes) = 01 FE 80 01 00 00 00 12 80 9A 02 00 40 80 C1 01 41 81 C2 11 40 04 20 40 00 00
from 4 entering 4
[SNIFFER] EXI from 50095 to 15118 (20bytes) = 80 9A 02 00 40 80 C1 01 41 81 C2 11 30 20 00 0A 00 00 00 00
[SNIFFER] EXI from 15118 to 50095 (18bytes) = 80 9A 02 00 40 80 C1 01 41 81 C2 11 40 04 20 40 00 00
[SNIFFER] EXI from 50095 to 15118 (13bytes) = 80 9A 02 00 40 80 C1 01 41 81 C2 11 F0
In state WaitForFlexibleRequest, received (21bytes) = 01 FE 80 01 00 00 00 0D 80 9A 02 00 40 80 C1 01 41 81 C2 11 F0
{
"info": "13 bytes to convert",
"error": "",
"result": "",
"schema": "DIN",
"g_errn": "0",
"msgName": "SessionStopReq",
"debug": "Line544"
}
connection closed
from 4 entering 0
C:\UwesTechnik\pyPLC>