mirror of
https://github.com/openhp/HeatPumpController.git
synced 2024-11-18 12:33:59 +00:00
Update README.md
This commit is contained in:
parent
03869fe98a
commit
2c3e936643
1 changed files with 1 additions and 1 deletions
|
@ -277,7 +277,7 @@ To get precise temperature readings sensors must be insulated from ambient air t
|
|||
<img src="./m_ds18b20_evaporator_mount.jpg" height="700"><br><br>
|
||||
About water(glycol)<->refrigerant heat exchangers. You can use plate heat exchangers. Pros: best efficiency. Cons: costs money.<br>
|
||||
<img src="./m_plate_heat_exchangers.jpg" width="500"><br><br>
|
||||
And requires oxygen brazing with "(20%+)silver-copper" solder here.
|
||||
And oxygen brazing with (20%+)silver+copper solder required here:
|
||||
<img src="./m_plate_echangers_oxygen_brazing.jpg" width="500"><br><br>
|
||||
You can build your own "tube-in-tube" heat exchangers. It's not hard. Cheaper. The heat exchange efficiency is worse. Very easy soldering.<br>
|
||||
{-pictures here-}<br>
|
||||
|
|
Loading…
Reference in a new issue