## Firmware options and fine tunings
|
||||
|
||||
QA tests, uncomment to enable
|
||||
```c
|
||||
//#define SELFTEST_RELAYS_LEDS_SPEAKER //speaker and relays QA test, uncomment to enable
|
||||
//#define SELFTEST_EEV //EEV QA test, uncomment to enable
|
||||
//#define SELFTEST_T_SENSORS //temperature sensors QA test, uncomment to enable
|
||||
```
|
||||
|
||||
//communication protocol with external world
|
||||
Communication protocol with external world, choose one
|
||||
|
||||
```c
|
||||
//#define RS485_JSON 1 //json, external systems integration
|
||||
//#define RS485_HUMAN 2 //RS485 is used in the same way as the local console, warning: Use only if 2 devices (server and this controller) are connected to the same RS485 line
|
||||
#define RS485_MODBUS 3 //default, Modbus via RS485, connection to the display (both sensor or 1602, see https://gitlab.com/valden/) or connection to any other MODBUS application or device
|
||||
```
|
||||
|
||||
//system type, comment both if HP with EEV
|
||||
System type, comment both if HP with EEV
|
||||
```c
|
||||
//#define EEV_ONLY //Valden controller as EEV controller: NO target T sensor. No relays. Oly EEV. Sensors required: Tae, Tbe, current sensor. Additional T sensors can be used but not required.
|
||||
//#define NO_EEV //capillary tube or TXV, EEV not used
|
||||
```
|
||||
|
||||
//which sensor is used to check setpoint, uncomment one of options
|
||||
Which sensor is used to check setpoint, uncomment one of options
|
||||
```c
|
||||
#define SETPOINT_THI //"warm floor" scheme: "hot in" (Thi) temperature used as setpoint
|
||||
//#define SETPOINT_TS1 //"swimming pool" or "water tank heater" scheme: "sensor 1" (Ts1) is used as setpoint and located somewhere in water tank
|
||||
```
|
||||
|
||||
Some more options
|
||||
```c
|
||||
#define HUMAN_AUTOINFO 30000 //print stats to console, every milliseconds
|
||||
|
||||
#define WATCHDOG //disable for older bootloaders
|
||||
//-----------------------USER OPTIONS END-----------------------
|
||||
```
|
||||
|
||||
Next sections: advanced options
|
||||
Temperature sensors used in a system, comment to disable
|
||||
|
||||
|
||||
//-----------------------Fine Tuning OPTIONS-----------------------
|
||||
//next sections: advanced options
|
||||
|
||||
|
||||
|
||||
//-----------------------T Sensors -----------------------
|
||||
//temperature sensors used in a system, comment to disable
|
||||
```c
|
||||
#define T_cold_in; //cold side (heat source) inlet sensor
|
||||
#define T_cold_out; //cold side outlet sensor
|
||||
#define T_before_evaporator; //"before" and "after evaporator" sensors are required to control EEV, both "EEV_ONLY" and "full" schemes
|
||||
|
@ -180,8 +186,10 @@ qwer
|
|||
#define T_hot_out; //hot side outlet
|
||||
//in full scheme Hot IN required! optional in "EEV_ONLY" scheme (see "EEV_ONLY" option),
|
||||
#define T_hot_in; //hot side inlet
|
||||
```
|
||||
|
||||
//-----------------------TEMPERATURES-----------------------
|
||||
Temperature limits
|
||||
```c
|
||||
#define MAGIC 0x66; //change this value if you want to rewrite the T setpoint in EEPROM
|
||||
#define T_SETPOINT 26.0; //This is a predefind target temperature value (start temperature). EEPROM-saved. The value can be changed using 1. Console 2. Changing the "setpoint" on a display 3. Changing this value AND changing "magic number"
|
||||
#define T_SETPOINT_MAX 48.0; //maximum "setpoint" temperature that an ordinary user can set
|
||||
|
@ -198,9 +206,10 @@ qwer
|
|||
|
||||
//#define T_REG_HEAT_THRESHOLD 17.0; //no longer used (PCB 1.3 MI +) artifact from experimental scheme with separator
|
||||
//#define T_HOTCIRCLE_DELTA_MIN 2.0; //not used since ~FW v1.6, "water heater with intermediate heat exchanger" scheme, where Ts1 == "sensor in water"; hot side CP will be switched on if "Ts1 - hot_out > T_HOTCIRCLE_DELTA_MIN"
|
||||
```
|
||||
|
||||
//-----------------------WATTS AND CYCLES TIMES-----------------------
|
||||
//time: milliseconds, power: watts
|
||||
Watts, cycles times (milliseconds)
|
||||
```c
|
||||
#define MAX_WATTS 1000.0 + 70.0 + 80.0 //power limit, watt, HP stops in case of exceeding, examples: installation1: compressor 165: 920 Watts, + 35 watts 25/4 circ. pump at 1st speed + 53 watts 25/4 circ. pump at 2nd speed
|
||||
// installation2: compressor unk: ~1000 + hot CP 70 + cold CP 80 = 1150 watts
|
||||
// installation3: and so on
|
||||
|
@ -213,13 +222,13 @@ qwer
|
|||
#define HOTCIRCLE_START_EVERY 2400000 //while pauses: pump on "hot side" starts every 40 minutes (by default) (max 9999 seconds) to circulate water and get exact temperature reading , option used if "warm floor" installation (Thi as setpoint)...
|
||||
#define HOTCIRCLE_CHECK_PREPARE 300000 //while pauses: ...and wait temperature stabilisation 5 minutes (by default), after that do setpoint checks...
|
||||
#define HOTCIRCLE_STOP_AFTER (HOTCIRCLE_CHECK_PREPARE + COLDCIRCLE_PREPARE + 30000) //...and then stop after few minutes of circulating, if temperature is high and no need to start compressor; value must be check_prepare + coldcircle_prepare + 30 seconds (or more)
|
||||
```
|
||||
|
||||
|
||||
//-----------------------EEV-----------------------
|
||||
//If you are using capillary tube or TXV: simply skip next section
|
||||
//Depending on how many milliseconds are allocated per step, the speed of automatic tuning will change.
|
||||
//Remember that you'll see refrigeration system reaction on every step not immediately, but after few minutes, sometimes after tens of minutes.
|
||||
|
||||
EEV options
|
||||
If you are using capillary tube or TXV: simply skip next section
|
||||
Depending on how many milliseconds are allocated per step, the speed of automatic tuning will change.
|
||||
Remember that you'll see refrigeration system reaction on every step not immediately, but after few minutes, sometimes after tens of minutes.
|
||||
```c
|
||||
#define EEV_MAXPULSES 250 //max steps, 250 is tested for sanhua 1.3
|
||||
|
||||
//steps tuning: mulliseconds per fast and slow (precise) steps
|
||||
|
@ -251,13 +260,15 @@ qwer
|
|||
|
||||
//do not use next option untill you're not really need it
|
||||
//#define EEV_DEBUG //debug, usefull during system fine tuning, works both with local serial and RS485_HUMAN
|
||||
//-----------------------ADDRESSES-----------------------
|
||||
```
|
||||
|
||||
```c
|
||||
const char devID = 0x45; //used only if JSON communication, does not matter for modbus and Valden display https://github.com/OpenHP/
|
||||
const char hostID = 0x30; //used only if JSON communication, not used for modbus
|
||||
|
||||
//-----------------------OTHER-----------------------
|
||||
```
|
||||
And last option
|
||||
```c
|
||||
#define MAX_SEQUENTIAL_ERRORS 15 //max cycles to wait auto-clean error, ex: T sensor appears, stop compressor after counter exceeded (millis_cycle * MAX_SEQUENTIAL_ERRORS)
|
||||
//-----------------------Fine Tuning OPTIONS END -----------------------
|
||||
```
|
||||
|
||||