## Firmware options and fine tunings
QA tests, uncomment to enable
```c
//#define SELFTEST_RELAYS_LEDS_SPEAKER //speaker and relays QA test, uncomment to enable
//#define SELFTEST_EEV //EEV QA test, uncomment to enable
//#define SELFTEST_T_SENSORS //temperature sensors QA test, uncomment to enable
```
//communication protocol with external world
Communication protocol with external world, choose one
```c
//#define RS485_JSON 1 //json, external systems integration
//#define RS485_HUMAN 2 //RS485 is used in the same way as the local console, warning: Use only if 2 devices (server and this controller) are connected to the same RS485 line
#define RS485_MODBUS 3 //default, Modbus via RS485, connection to the display (both sensor or 1602, see https://gitlab.com/valden/) or connection to any other MODBUS application or device
```
//system type, comment both if HP with EEV
System type, comment both if HP with EEV
```c
//#define EEV_ONLY //Valden controller as EEV controller: NO target T sensor. No relays. Oly EEV. Sensors required: Tae, Tbe, current sensor. Additional T sensors can be used but not required.
//#define NO_EEV //capillary tube or TXV, EEV not used
```
//which sensor is used to check setpoint, uncomment one of options
Which sensor is used to check setpoint, uncomment one of options
```c
#define SETPOINT_THI //"warm floor" scheme: "hot in" (Thi) temperature used as setpoint
//#define SETPOINT_TS1 //"swimming pool" or "water tank heater" scheme: "sensor 1" (Ts1) is used as setpoint and located somewhere in water tank
```
Some more options
```c
#define HUMAN_AUTOINFO 30000 //print stats to console, every milliseconds
#define WATCHDOG //disable for older bootloaders
//-----------------------USER OPTIONS END-----------------------
```
Next sections: advanced options
Temperature sensors used in a system, comment to disable
//-----------------------Fine Tuning OPTIONS-----------------------
//next sections: advanced options
//-----------------------T Sensors -----------------------
//temperature sensors used in a system, comment to disable
```c
#define T_cold_in; //cold side (heat source) inlet sensor
#define T_cold_out; //cold side outlet sensor
#define T_before_evaporator; //"before" and "after evaporator" sensors are required to control EEV, both "EEV_ONLY" and "full" schemes
@ -180,8 +186,10 @@ qwer
#define T_hot_out; //hot side outlet
//in full scheme Hot IN required! optional in "EEV_ONLY" scheme (see "EEV_ONLY" option),
#define T_hot_in; //hot side inlet
```
//-----------------------TEMPERATURES-----------------------
Temperature limits
```c
#define MAGIC 0x66; //change this value if you want to rewrite the T setpoint in EEPROM
#define T_SETPOINT 26.0; //This is a predefind target temperature value (start temperature). EEPROM-saved. The value can be changed using 1. Console 2. Changing the "setpoint" on a display 3. Changing this value AND changing "magic number"
#define T_SETPOINT_MAX 48.0; //maximum "setpoint" temperature that an ordinary user can set
@ -198,9 +206,10 @@ qwer
//#define T_REG_HEAT_THRESHOLD 17.0; //no longer used (PCB 1.3 MI +) artifact from experimental scheme with separator
//#define T_HOTCIRCLE_DELTA_MIN 2.0; //not used since ~FW v1.6, "water heater with intermediate heat exchanger" scheme, where Ts1 == "sensor in water"; hot side CP will be switched on if "Ts1 - hot_out > T_HOTCIRCLE_DELTA_MIN"
```
//-----------------------WATTS AND CYCLES TIMES-----------------------
//time: milliseconds, power: watts
Watts, cycles times (milliseconds)
```c
#define MAX_WATTS 1000.0 + 70.0 + 80.0 //power limit, watt, HP stops in case of exceeding, examples: installation1: compressor 165: 920 Watts, + 35 watts 25/4 circ. pump at 1st speed + 53 watts 25/4 circ. pump at 2nd speed
// installation2: compressor unk: ~1000 + hot CP 70 + cold CP 80 = 1150 watts
// installation3: and so on
@ -213,13 +222,13 @@ qwer
#define HOTCIRCLE_START_EVERY 2400000 //while pauses: pump on "hot side" starts every 40 minutes (by default) (max 9999 seconds) to circulate water and get exact temperature reading , option used if "warm floor" installation (Thi as setpoint)...
#define HOTCIRCLE_CHECK_PREPARE 300000 //while pauses: ...and wait temperature stabilisation 5 minutes (by default), after that do setpoint checks...
#define HOTCIRCLE_STOP_AFTER (HOTCIRCLE_CHECK_PREPARE + COLDCIRCLE_PREPARE + 30000) //...and then stop after few minutes of circulating, if temperature is high and no need to start compressor; value must be check_prepare + coldcircle_prepare + 30 seconds (or more)
```
//-----------------------EEV-----------------------
//If you are using capillary tube or TXV: simply skip next section
//Depending on how many milliseconds are allocated per step, the speed of automatic tuning will change.
//Remember that you'll see refrigeration system reaction on every step not immediately, but after few minutes, sometimes after tens of minutes.
EEV options
If you are using capillary tube or TXV: simply skip next section
Depending on how many milliseconds are allocated per step, the speed of automatic tuning will change.
Remember that you'll see refrigeration system reaction on every step not immediately, but after few minutes, sometimes after tens of minutes.
```c
#define EEV_MAXPULSES 250 //max steps, 250 is tested for sanhua 1.3
//steps tuning: mulliseconds per fast and slow (precise) steps
@ -251,13 +260,15 @@ qwer
//do not use next option untill you're not really need it
//#define EEV_DEBUG //debug, usefull during system fine tuning, works both with local serial and RS485_HUMAN
//-----------------------ADDRESSES-----------------------
```
```c
const char devID = 0x45; //used only if JSON communication, does not matter for modbus and Valden display https://github.com/OpenHP/
const char hostID = 0x30; //used only if JSON communication, not used for modbus
//-----------------------OTHER-----------------------
```
And last option
```c
#define MAX_SEQUENTIAL_ERRORS 15 //max cycles to wait auto-clean error, ex: T sensor appears, stop compressor after counter exceeded (millis_cycle * MAX_SEQUENTIAL_ERRORS)
//-----------------------Fine Tuning OPTIONS END -----------------------
```
## Diagnostic and troubleshooting