@ -128,18 +128,18 @@ qwer
qwer
## Diagnostic and status messages
**LastStopCause messages. Why system was stopped**<br>
**LastStopCause messages. Why system was stopped**<br><br>
**P.WtMax:_WATTS_** Protective stop, overcurrent, double check your system, **MAX_WATTS** and **POWERON_HIGHTIME** options<br>
**E.Tci, E.Tco, E.Tbe, E.Tae, E.Ts1, E.Ts2, E.Tcrc, E.Treg, E.Tac, E.Tbc, E.Tho, E.Thi** Sensor lost, check wiring. Refer to "T sensors abbreviations"<br>
**E.PresCold** Cold side pressure too low, check refrigerant charge and pressure sensors<br>
**E.PresHot** Hot side pressure too high, check refrigerant charge and pressure sensors<br>
<br>
**LastStartMessage messages. what event system is waiting for starting work**<br>
**StCntd:_seconds_** startup countdown, short-term power loss protection
**#HotPrp:_seconds_** hot side pump is on, waiting for T stabilisation countdown see **HOTCIRCLE_CHECK_PREPARE** option
**#HotSlp:_seconds_** sleepeng, last cycle temperature was > setpoint, waiting for next startup, see **HOTCIRCLE_START_EVERY** option
**#HPSlp:_seconds_**" + String( (mincycle_poweroff -(unsigned long)(millis_now - millis_last_heatpump_on))/1000 );
<br>
**LastStartMessage messages. what event system is waiting for starting work**<br><br>
**StCntd:_seconds_** startup countdown, short-term power loss protection<br>
**#HotPrp:_seconds_** hot side pump is on, waiting for T stabilisation countdown see **HOTCIRCLE_CHECK_PREPARE** option<br>
**#HotSlp:_seconds_** sleepeng, last cycle temperature was > setpoint, waiting for next startup, see **HOTCIRCLE_START_EVERY** option<br>
**#HPSlp:_seconds_**" + String( (mincycle_poweroff -(unsigned long)(millis_now - millis_last_heatpump_on))/1000 );<br>
**#Tho>Max**<br>
**#Thi>Max**<br>