vmctl: properly convert influx bools into integer representation
When using vmctl influx, the import would fail importing boolean fields
with:
```
failed to convert value "some".0 to float64: unexpected value type true
```
This converts `true` to `1` and `false` to `0`.
Fixes#1709
Sort series by a hash calculated from the series labels. This should guarantee "random" selection of the returned time series.
Previously the selection could be biased, since time series were sorted alphabetically by label names and label values.
Stream parsing mode can be automatically enabled when scraping targets with big response bodies
exceeding the -promscrape.minResponseSizeForStreamParse , so it must be always initialized.
This allows sending staleness marks and properly calculate scrape_series_added metric in stream parsing mode
at the cost of the increased memory usage, since now the potentially big response is kept
in the lastScrape byte slice per each scrapeWork.
In practice the memory usage increase shouldn't be big, since the response size
is usually much smaller than the parsed metrics from this response after the relabeling,
which usually adds a big pile of target-specific labels per each metric.
* vmalert: adjust `http.Transport.MaxIdleConns` value accordingly to `http.Transport.MaxIdleConnsPerHost`
`http.Transport.MaxIdleConnsPerHost` setting is controlled by `datasource.maxIdleConnections` flag,
while `http.Transport.MaxIdleConns` is inherited from DefaultTransport and is equal to `100`.
The fix adjusts `http.Transport.MaxIdleConns` value if it is lower than `http.Transport.MaxIdleConnsPerHost`.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* vmauth: adjust `http.Transport.MaxIdleConns` value accordingly to `http.Transport.MaxIdleConnsPerHost`
`http.Transport.MaxIdleConnsPerHost` setting is controlled by `maxIdleConnsPerBackend` flag,
while `http.Transport.MaxIdleConns` is inherited from DefaultTransport and is equal to `100`.
The fix adjusts `http.Transport.MaxIdleConns` value if it is lower than `http.Transport.MaxIdleConnsPerHost`.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
The source link is controlled by `external.url` and `external.alert.source`
flags, in the same way as for alertmanager notifications.
The source link is added to Alerts list view, and specific Alert view.
* added guide for VM operator
* Update docs/guides/getting-started-with-vm-operator.md
Co-authored-by: Roman Khavronenko <hagen1778@gmail.com>
* Update docs/guides/getting-started-with-vm-operator.md
Co-authored-by: Roman Khavronenko <hagen1778@gmail.com>
* Fixed different typos and added improvements from proposals
* move remoteWrite.url to other place
* fixed typo
* rephrased vminsert explanation
* remove not needed parameters for default setup
Co-authored-by: Roman Khavronenko <hagen1778@gmail.com>