{vmagent/remotewrite,vminsert/common}: fix dropInput and keepInput flags inconsistency
Sync behavior for dropInput and keepInput flags between single-node and vmagent.
Fix vmagent not respecting dropInput flag and reverse logic for keepInput.
* Revert "vmalert: unittest support stale datapoint (#4696)"
This reverts commit 0b44df7ec8.
* Revert "docs: specify min version and limitations for vmalert's unit tests"
This reverts commit a24541bd
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* Revert "vmalert: init unit test (#4596)"
This reverts commit da60a68d
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* docs: mention unittest revert in changelog
Signed-off-by: hagen1778 <roman@victoriametrics.com>
---------
Signed-off-by: hagen1778 <roman@victoriametrics.com>
- Use a byte slice instead of a map for tracking indexes for matching series.
This improves performance, since access by slice index is faster than access by map key.
- Re-use the byte slice for tracking indexes for matching series.
This removes unnecessary memory allocations and improves stream aggregation performance a bit.
- Add an ability to return to the previous behvaiour by specifying -remoteWrite.streamAggr.dropInput command-line flag.
In this case all the input samples are dropped when stream aggregation is enabled.
- Backport the new stream aggregation behaviour from vmagent to single-node VictoriaMetrics when -streamAggr.config
option is set.
- Improve docs regarding this change at docs/CHANGELOG.md
- Document the new behavior at docs/stream-aggregation.md
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4243
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/pull/4575
* {lib/streamaggr,vmagent/remotewrite}: breaking change for keepInput flag
Changes default behaviour of keepInput flag to write series which did not match any aggregators to the remote write.
See: https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4243
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* Update app/vmagent/remotewrite/remotewrite.go
Co-authored-by: Roman Khavronenko <roman@victoriametrics.com>
---------
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
Co-authored-by: Roman Khavronenko <roman@victoriametrics.com>
Co-authored-by: Aliaksandr Valialkin <valyala@victoriametrics.com>
Without reset, labels duplicates could have been added during stream aggregation.
Since `ctx.Labels` is reused during processing of many series, each series will
add its labels to the context. Even if the same labels were already addeded on prev
iteration. Now, we reset `ctx.Labels` on each iteration to contain so labels from
different series didn't interfere.
This could have cause exceeding of the limit on number of labels per pushed time series.
https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4277
Signed-off-by: hagen1778 <roman@victoriametrics.com>
- Make sure that the last successfully loaded config is used on hot-reload failure
- Properly cleanup resources occupied by already initialized aggregators
when the current aggregator fails to be initialized
- Expose distinct vmagent_streamaggr_config_reload* metrics per each -remoteWrite.streamAggr.config
This should simplify monitoring and debugging failed reloads
- Remove race condition at app/vminsert/common.MustStopStreamAggr when calling sa.MustStop() while sa
could be in use at realoadSaConfig()
- Remove lib/streamaggr.aggregator.hasState global variable, since it may negatively impact scalability
on system with big number of CPU cores at hasState.Store(true) call inside aggregator.Push().
- Remove fine-grained aggregator reload - reload all the aggregators on config change instead.
This simplifies the code a bit. The fine-grained aggregator reload may be returned back
if there will be demand from real users for it.
- Check -relabelConfig and -streamAggr.config files when single-node VictoriaMetrics runs with -dryRun flag
- Return back accidentally removed changelog for v1.87.4 at docs/CHANGELOG.md
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/3639
This option can be useful when samples for the same time series are ingested with distinct order of labels.
For example, metric{k1="v1",k2="v2"} and metric{k2="v2",k1="v1"}.
Previously the enabled relabeling with `-relabelConfig` command-line flag could result in missing labels
if a single Influx line protocol message contains multiple field values.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/638
ReadLinesBlock may accept dstBuf with non-zero length. In this case the last line without trailing newline isn't read.
Fix this by comparing len(dstBuf) to 0 instead of its original length.