Previously the query could return incorrect results, since the query timestamp was updated with every Query.Clone() call
during iterative search for the time range with up to limit=N rows.
While at it, optimize queries, which find low number of matching logs, while spend a lot of CPU time for searching
across big number of logs. The optimization reduces the upper bound of the time range to search if the current time range
contains zero matching rows.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/6785
### Describe Your Changes
Add storage metrics that count records that failed to insert:
- `RowsReceivedTotal`: the number of records that have been received by
the storage from the clients
- `RowsAddedTotal`: the number of records that have actually been
persisted. This value must be equal to `RowsReceivedTotal` if all the
records have been valid ones. But it will be smaller otherwise. The
values of the metrics below should provide the insight of why some
records hasn't been added
- `NaNValueRows`: the number of records whose value was `NaN`
- `StaleNaNValueRows`: the number of records whose value was `Stale NaN`
- `InvalidRawMetricNames`: the number of records whose raw metric name
has failed to unmarshal.
The following metrics existed before this PR and are listed here for
completeness:
- `TooSmallTimestampRows`: the number of records whose timestamp is
negative or is older than retention period
- `TooBigTimestampRows`: the number of records whose timestamp is too
far in the future.
- `HourlySeriesLimitRowsDropped`: the number of records that have not
been added because the hourly series limit has been exceeded.
- `DailySeriesLimitRowsDropped`: the number of records that have not
been added because the daily series limit has been exceeded.
---
Signed-off-by: Artem Fetishev <wwctrsrx@gmail.com>
Commit adds the following changes:
* Adds support of OpenTelemetry logs for Victoria Logs with protobuf encoded messages
* json encoding is not supported for the following reasons:
- It brings a lot of fragile code, which works inefficiently.
- json encoding is impossible to use with language SDK.
* splits metrics and logs structures at lib/protoparser/opentelemetry/pb package.
* adds docs with examples for opentelemetry logs.
---
Related issue: https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4839
Co-authored-by: AndrewChubatiuk <andrew.chubatiuk@gmail.com>
Co-authored-by: f41gh7 <nik@victoriametrics.com>
* updates change log
* adds VL-Debug http header
* updates doc
* extracts only the first value of http headers for VL-Stream-Fields and VL-Ignore-Fields.
It makes behaviour the same as Query string args. And allows to easily configure client applications.
Since most of the client collectors don't support multi value headers.
Signed-off-by: f41gh7 <nik@victoriametrics.com>
* Many collectors don't support forwarding url query params to the remote system. It makes impossible to define stream fields for it. Workaround with proxy between VictoriaLogs and log shipper is too complicated solution.
* This commit adds the following changes:
* Adds fallback to to headers params, if query param is empty for:
_msg_field -> VL-Msg-Field
_stream_fields -> VL-Stream-Fields
_ignore_fields -> VL-Ignore-Fields
_time_field -> VL-Time-Field
* removes deprecations from victorialogs compose files, added more
output format examples for logstash, telegraf, fluent-bit
related issue: https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5310
Recent versions of `docker build` started generating the InvalidDefaultArgInFrom warning if Dockerfile contains
an ARG without default value. While this warning doesn't affect building Docker packages via `make package-*` commands,
it is better suppressing the warning, so it doesn't clutter `make package-*` output with the noise,
which can hide real issues in the future.
…specifying `-streamAggr.dedupInterval` or
`-remoteWrite.streamAggr.dedupInterval` command-line flag
[The
documentation](https://docs.victoriametrics.com/stream-aggregation/)
contains conflicting descriptions regarding deduplication for
non-matched series when `-remoteWrite.streamAggr.config` and / or
`-streamAggr.config` are set:
1. Statement below says **all the received data** is deduplicated:
>[vmagent](https://docs.victoriametrics.com/vmagent/) supports
relabeling, deduplication and stream aggregation for all the received
data, scraped or pushed. Then, the collected data will be forwarded to
specified -remoteWrite.url destinations. The data processing order is
the following:
>1. all the received data is relabeled according to the specified
[-remoteWrite.relabelConfig](https://docs.victoriametrics.com/vmagent/#relabeling)
(if it is set)
>2. all the received data is deduplicated according to specified
[-streamAggr.dedupInterval](https://docs.victoriametrics.com/stream-aggregation/#deduplication)
(if it is set to duration bigger than 0)
2. Another statement says the deduplication is performed individually
for the **matching samples**
>The de-deduplication is performed after applying
[relabeling](https://docs.victoriametrics.com/vmagent/#relabeling) and
before performing the aggregation. If the -remoteWrite.streamAggr.config
and / or -streamAggr.config is set, then the de-duplication is performed
individually per each [stream aggregation
config](https://docs.victoriametrics.com/stream-aggregation/#stream-aggregation-config)
for the matching samples after applying
[input_relabel_configs](https://docs.victoriametrics.com/stream-aggregation/#relabeling).
Considering the following deduplication use cases:
1. To apply deduplication(globally or for specific remoteWrite
destination) for all the received data, scraped or pushed
--- using `-streamAggr.dedupInterval` or
`-remoteWrite.streamAggr.dedupInterval`.
2. To deduplicate and aggregate metrics that match the rule `match`
filters
--- using `-remoteWrite.streamAggr.config` and specifiying
`dedup_interval` option in [stream aggregation
config](https://docs.victoriametrics.com/stream-aggregation/#stream-aggregation-config).
3. To deduplicate all the received data while having `streamAggr.config`
for some metrics
--- no way for a single vmagent now, need to set up two level vmagents
This PR implements case3.
---------
Co-authored-by: Roman Khavronenko <roman@victoriametrics.com>
add command-line flag `-search.inmemoryBufSizeBytes` for configuring size of in-memory buffers used by vmselect during processing of vmstorage responses. A new summary metric `vm_tmp_blocks_inmemory_file_size_bytes` is exposed to show the size of the buffer during requests processing.
The new setting can be used by experienced users to adjust memory usage by vmselect when processing
many small read requests. Instead of allocating 4MB buffers each time, vmselect can be instructed to lower
the buffer size via `-search.inmemoryBufSizeBytes`. To make the decision whether this flag needs to be adjusted
users can consult with `vm_tmp_blocks_inmemory_file_size_bytes` which shows the actual size of buffers used
during query processing.
----------
The detailed information of this PR can be found in
https://github.com/VictoriaMetrics/VictoriaMetrics/pull/6851
### Checklist
The following checks are **mandatory**:
- [ ] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
---------
Co-authored-by: hagen1778 <roman@victoriametrics.com>
(cherry picked from commit cab3ef8294)
## Describe Your Changes
Add RemoteWrite Retry Controls
This PR introduces two new flags to the remote write functionality:
- remoteWrite.retryMinInterval
- remoteWrite.retryMaxTime
These flags provide finer control over the retry behavior for
remoteWrite operations, allowing users to customize the minimum interval
between retries and the maximum duration for retry attempts.
Fixes#5486.
## Checklist
- [x] The following checks are mandatory:
My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
---------
Signed-off-by: Yury Akudovich <ya@matterlabs.dev>
Co-authored-by: hagen1778 <roman@victoriametrics.com>
This change is made in attempt to reduce memory usage by vmalert when
parsing big instant responses from VM/Prometheus.
In
a5c427bac4
vmalert switched from std json lib to fastjson lib in order to reduce
amount of allocations, as according to highloaded profiles of vmalert
the CPU is mostly spent on GC.
But switching to fastjson resulted into excessive memory usage for cases
when vmalert has to parse long json lines, which usually happens when
instant response contains many `metric` objects.
In this change we do a mixed parsing:
1. Slice of `metric` objects is parsed with std lib to keep mem low
2. Each `metric` object is parsed with fastjson to reduce allocs
The benchmark results are the following:
```
pkg: github.com/VictoriaMetrics/VictoriaMetrics/app/vmalert/datasource
BenchmarkParsePrometheusResponse/Instant_std+fastjson-10 1760 668959 ns/op 280147 B/op 5781 allocs/op
MBs allocated at heap: 493.078392
mallocs: 18655472
BenchmarkParsePrometheusResponse/Instant_fastjson-10 6109 198258 ns/op 172839 B/op 5548 allocs/op
MBs allocated at heap: 1056.384464
mallocs: 34457184
BenchmarkParsePrometheusResponse/Instant_std-10 1287 950987 ns/op 451677 B/op 9619 allocs/op
MBs allocated at heap: 580.802976
mallocs: 13351636
```
The benchmark function code with mem measurement is available here
https://gist.github.com/hagen1778/b9c3ca7f8ca7d6b21aec9777112c5810
The benchmark contains 3 results:
1. Instant_std+fastjson is the implementation in this change
2. Instant_fastjson-10 is the implementation from
a5c427bac4
3. BenchmarkParsePrometheusResponse/Instant_std-10 is implementation
before
a5c427bac4
According to these results, this new implementation is slower than
previous, but faster than before switching to fastjson. It also has
lower number of allocations and roughly the same memory allocation on
heap with GC turned off.
---------
Other changes:
1. rm BenchmarkMetrics as it doesn't measure anything
2. simplify BenchmarkParsePrometheusResponse into
BenchmarkPromInstantUnmarshal
### Describe Your Changes
Please provide a brief description of the changes you made. Be as
specific as possible to help others understand the purpose and impact of
your modifications.
### Checklist
The following checks are **mandatory**:
- [ ] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
Signed-off-by: hagen1778 <roman@victoriametrics.com>
- fix TS lint
- anomaly: remove /vmui
- anomaly: minor inspections fix
- docs: fix broken links to headings
### Describe Your Changes
Initially vmanomaly opened with `/vmui` in serverUrl, remove it.
to allow configuring additional headers in each request to the
corresponding notifier.
Other flags like `-datasource.headers`, `-remoteWrite.headers` already
use `^^` as delimiter, it's consistent to use it in `-notifier.headers`
as well.
related https://github.com/VictoriaMetrics/VictoriaMetrics/issues/3260
vmalert can integrate with alertmanager that supports multi-tenant by
adding tenantID header`X-Scope-OrgID` in requests.
In multitenancy, vmalert can also filter alerts which send to different
notifier addresses(or with different header settings) using
`alert_relabel_configs`.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/3260
---------
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Co-authored-by: hagen1778 <roman@victoriametrics.com>
Production workload shows that it's useful optimisation.
Channel based objects pool allows to handle irregural data ingestion
requests and make memory allocations more smooth.
It's improves sync.Pool efficiency, since objects from sync.Pool removed
after 2 GC cycles. With GOGC=30 value, GC runs significantly more often.
https://github.com/VictoriaMetrics/VictoriaMetrics/issues/6733
### Checklist
The following checks are **mandatory**:
- [ ] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
---------
Signed-off-by: f41gh7 <nik@victoriametrics.com>
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Co-authored-by: hagen1778 <roman@victoriametrics.com>
(cherry picked from commit f255800da3)
Signed-off-by: hagen1778 <roman@victoriametrics.com>
# Conflicts:
# app/vminsert/common/insert_ctx_pool.go
Describe Your Changes
When I use usePromCompatibleNaming with vmagent to process data that
needs to be formatted from different sources such as InfluxDB, I find
that it doesn’t work
However, it works in vminsert. I found that vminsert uses the
HasRelabeling method to determine whether to relabel.
```go
func HasRelabeling() bool {
pcs := pcsGlobal.Load()
return pcs.Len() > 0 || *usePromCompatibleNaming
}
```
in vmagent, the decision to relabel is determined only by
pcsGlobal.Len() > 0. However, in the applyRelabeling method, the
usePromCompatibleNaming logic is also used to determine whether to
relabel in the error handling.
```go
func (rctx *relabelCtx) applyRelabeling(tss []prompbmarshal.TimeSeries, pcs *promrelabel.ParsedConfigs) []prompbmarshal.TimeSeries {
if pcs.Len() == 0 && !*usePromCompatibleNaming {
// Nothing to change.
return tss
}
```
So I think that the logic for determining whether to relabel in vmagent
is not as expected.
Checklist
The following checks are mandatory:
[✅]My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
---------
Co-authored-by: Roman Khavronenko <hagen1778@gmail.com>
…eep_metric_names` options in stream aggregation config together
With aggregated data and raw data under the same metric, results would
be confusing.
---------
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Co-authored-by: hagen1778 <roman@victoriametrics.com>
Make `-remoteWrite.streamAggr.ignoreFirstIntervals` of array type so it could
accept multiple values which can be applied to the corresponding`-remoteWrite.url`.
---------
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Co-authored-by: hagen1778 <roman@victoriametrics.com>
Fix `-streamAggr.dropInputLabels` behavior when global deduplication is enabled without `-streamAggr.config`.
Previously, `-remoteWrite.streamAggr.dropInputLabels` is misapplied.
---------
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Co-authored-by: hagen1778 <roman@victoriametrics.com>
The error check was needed before a84491324d
It was kept by mistake and makes no sense to have rn.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
### Describe Your Changes
- Adds support for displaying the top 5 log streams in the hits graph,
grouping the remaining streams into an "other" label.
#6545
- Adds options to customize the graph display with bar, line, stepped
line, and points views.
### Checklist
The following checks are **mandatory**:
- [x] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
### Describe Your Changes
This is useful for clients which validate InfluxDB is available before
data ingestion can be started.
See: https://github.com/VictoriaMetrics/VictoriaMetrics/issues/6653
### Checklist
The following checks are **mandatory**:
- [x] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
---------
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Co-authored-by: hagen1778 <roman@victoriametrics.com>
### Describe Your Changes
Added `--vm-backoff-retries`, `--vm-backoff-factor`,
`--vm-backoff-min-duration` and `--vm-native-backoff-retries`,
`--vm-native-backoff-factor`, `--vm-native-backoff-min-duration`
command-line flags to the `vmctl` app. Those changes will help to
configure the retry backoff policy for different situations.
Related issue:
https://github.com/VictoriaMetrics/VictoriaMetrics/issues/6622
### Checklist
The following checks are **mandatory**:
- [X] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
---------
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Co-authored-by: hagen1778 <roman@victoriametrics.com>
* add a toggle button to the "Group" tab that allows users to expand or collapse all groups at once
* introduce the ability to select a key for grouping logs within the "Group" tab
* display the number of entries within each log group.
* move the Markdown toggle to the general settings panel in the upper left corner.
### Describe Your Changes
Change response code to 502 to align it with behaviour of other existing
reverse proxies. Currently, the following reverse proxies will return
502 in case an upstream is not available: nginx, traefik, caddy, apache.
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>