added supercharger test results

This commit is contained in:
uhi22 2023-03-02 21:32:41 +01:00
parent dbe5470fdb
commit 533c95a507
2 changed files with 31 additions and 2 deletions

View file

@ -1,5 +1,17 @@
# Open issues # Open issues
## Issue 18: On SuperCharger we ignore the session ID
- In the SessionSetupResponse, the SuperCharger V3 correctly provides a sessionID, e.g. "06ef0071".
- But we ignore this, and send in all next messages (starting with ServiceDiscoveryReq) the sessionID "deadbeefdeadbeef".
- The SuperCharger correctly complains with "ResponseCode": "FAILED_UnknownSession".
- observed with Software version v0.5-12-g23b1384, on 2023-03-02.
- root cause: In main_commandlineinterface.c we check, whether the session ID has 16 characters, to represent 8 hex bytes.
But the SuperCharger provides 8 characters, to present 4 bytes. Thats why the function useSessionIdFromCommandLine()
operates with the default session ID "deadbeefdeadbeef".
- solution: in function useSessionIdFromCommandLine(), also accept shorter session IDs. And in function init_dinMessageHeaderWithSessionID(),
use a dynamic length instead of the fixed length LEN_OF_SESSION_ID (=8).
## Issue 17: Welding detection fails ## Issue 17: Welding detection fails
- WeldingDetectionRes says "failed" on alpitronics, and no response on ABBHPC and ABBTriple - WeldingDetectionRes says "failed" on alpitronics, and no response on ABBHPC and ABBTriple
- version v0.4-7-g7cea8b5 (2022-12-21) - version v0.4-7-g7cea8b5 (2022-12-21)

View file

@ -145,7 +145,24 @@ Test results tbd
## Tesla Supercharger V3 ## Tesla Supercharger V3
Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/Supercharger-Car-Wash-Ruppertswies-4/69557/ Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/Supercharger-Car-Wash-Ruppertswies-4/69557/
or https://www.goingelectric.de/stromtankstellen/Deutschland/Pfaffenhofen-an-der-Ilm/Supercharger-Hotel-Strasshof-Siebenecken-1/44134/
Test results Test results of version v0.5-12-g23b1384, on 2023-03-02
- [ ] SLAC: fails. It sends SLAC_PARAM_CNF, but nothing more. - [x] SLAC
- [x] SDP
- [x] TCP connection
- [x] EXI
- [x] DIN SupportedApplicationProtocol
- [x] DIN SessionSetup
- [x] DIN ServiceDiscovery
- [x] DIN ServicePaymentSelection
- [x] DIN ContractAuthentication
- [x] DIN ChargeParameterDiscovery
- [ ] DIN CableCheck: The cable check runs into timeout. No real voltage on the pins. Maybe caused by wrong sessionId, see issue 18.
- [ ] DIN PreCharge
- [ ] DIN PowerDelivery Start
- [ ] DIN CurrentDemand
- [ ] DIN PowerDelivery Stop
- [ ] DIN WeldingDetection
- [ ] DIN SessionStop