pyPLC/doc/charger_test_results.md
2023-03-02 21:32:41 +01:00

5.4 KiB

Test Results on different Real-World Chargers

ABB Terra 53 Triple Charger

Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolstadt/hagebaumarkt-Siemensstrasse-1/48209/

Test results of version v0.4-7-g7cea8b5 (2022-12-21, Köschinger Forst Ost)

  • SLAC
  • SDP
  • TCP connection
  • EXI
    • DIN SupportedApplicationProtocol
    • DIN SessionSetup
    • DIN ServiceDiscovery
    • DIN ServicePaymentSelection
    • DIN ContractAuthentication
    • DIN ChargeParameterDiscovery
    • DIN CableCheck
    • DIN PreCharge
    • DIN PowerDelivery Start
    • DIN CurrentDemand: Light bulb demo works
    • DIN PowerDelivery Stop
    • DIN WeldingDetection no response 2022-12-21T08:50:36.640899, issue 17
    • DIN SessionStop
  • Inlet voltage measurement

ABB Terra HPC

Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/Total-Tankstelle-Ruppertswies-6/63794/

Test results of version v0.4-7-g7cea8b5 (2022-12-21)

  • SLAC
  • SDP
  • TCP connection
  • EXI
    • DIN SupportedApplicationProtocol
    • DIN SessionSetup
    • DIN ServiceDiscovery
    • DIN ServicePaymentSelection
    • DIN ContractAuthentication
    • DIN ChargeParameterDiscovery
    • DIN CableCheck
    • DIN PreCharge
    • DIN PowerDelivery Start
    • DIN CurrentDemand: Light bulb demo works
    • DIN PowerDelivery Stop
    • DIN WeldingDetection: No response 2022-12-21T08:36:29.943830, issue 17
    • DIN SessionStop
  • Inlet voltage measurement

Alpitronic HPC HYC300

Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolstadt/Dehner-Garten-Center-Degenhartstrasse-Degenhartstrasse-2/71112/

Test results of version v0.4-7-g7cea8b5 (2022-12-21)

  • SLAC
  • SDP
  • TCP connection
  • EXI
    • DIN SupportedApplicationProtocol
    • DIN SessionSetup
    • DIN ServiceDiscovery
    • DIN ServicePaymentSelection
    • DIN ContractAuthentication
    • DIN ChargeParameterDiscovery
    • DIN CableCheck
    • DIN PreCharge
    • DIN PowerDelivery Start
    • DIN CurrentDemand: Light bulb demo works
    • DIN PowerDelivery Stop
    • DIN WeldingDetection: "ResponseCode": "FAILED", issue 17
    • DIN SessionStop: No response
  • Inlet voltage measurement (shows 500V during cable check, and 230V during precharge)

Compleo Cito BM 500

Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/EDEKA-Ingolstaedter-Strasse-114/62619/

Test results of version v0.4

  • SLAC
  • SDP
  • TCP connection
  • EXI
    • DIN SupportedApplicationProtocol
    • DIN SessionSetup
    • DIN ServiceDiscovery
    • DIN ServicePaymentSelection
    • DIN ContractAuthentication
    • DIN ChargeParameterDiscovery
    • DIN CableCheck (10s loop ongoing, then finished OK)
    • DIN PreCharge ok, but at the end the state machine runs into timeout. Issue 15.
    • DIN PowerDelivery, CurrentDemand

Efacec QC45 Triple Charger

Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Hepberg/Koeschinger-Forst-West-A9/15982/

Test results of version v0.4-7-g7cea8b5 (2022-12-21)

  • SLAC
  • SDP
  • TCP connection
  • EXI
    • DIN SupportedApplicationProtocol
    • DIN SessionSetup
    • DIN ServiceDiscovery
    • DIN ServicePaymentSelection
    • DIN ContractAuthentication: Due to defective charger, no authorization possible via app or RFID.

Efacec HPC Efapower Kiosk HV175

Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Neufahrn-bei-Freising/Fuerholzen-West-A9/22771/

Test tbd

Ionity Tritium Veefil-PK

Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Hepberg/IONITY-Koeschinger-Forst-Ost-A9/37875/

Test results of version v0.4-7-g7cea8b5

  • SLAC
  • SDP
  • TCP connection
  • EXI
    • DIN SupportedApplicationProtocol
    • DIN SessionSetup
    • DIN ServiceDiscovery
    • DIN ServicePaymentSelection
    • DIN ContractAuthentication
    • DIN ChargeParameterDiscovery
    • DIN CableCheck
    • DIN PreCharge
    • DIN PowerDelivery Start
    • DIN CurrentDemand: With the light-bulb configuration, the charger overshoots the intended voltage, because no load is connected at the start of the charging loop. Then, after a few seconds, the charger stops.
    • DIN PowerDelivery Stop
    • DIN WeldingDetection
    • DIN SessionStop
  • Inlet voltage measurement

Porsche

Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolstadt/Audi-Forum-Ettinger-Strasse/7970/

Test results tbd

Tesla Supercharger V3

Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/Supercharger-Car-Wash-Ruppertswies-4/69557/ or https://www.goingelectric.de/stromtankstellen/Deutschland/Pfaffenhofen-an-der-Ilm/Supercharger-Hotel-Strasshof-Siebenecken-1/44134/

Test results of version v0.5-12-g23b1384, on 2023-03-02

  • SLAC
  • SDP
  • TCP connection
  • EXI
    • DIN SupportedApplicationProtocol
    • DIN SessionSetup
    • DIN ServiceDiscovery
    • DIN ServicePaymentSelection
    • DIN ContractAuthentication
    • DIN ChargeParameterDiscovery
    • DIN CableCheck: The cable check runs into timeout. No real voltage on the pins. Maybe caused by wrong sessionId, see issue 18.
    • DIN PreCharge
    • DIN PowerDelivery Start
    • DIN CurrentDemand
    • DIN PowerDelivery Stop
    • DIN WeldingDetection
    • DIN SessionStop