mirror of
https://github.com/uhi22/pyPLC.git
synced 2024-11-10 01:05:42 +00:00
added charger_test_results.md
This commit is contained in:
parent
523ab8c184
commit
591a2a2190
1 changed files with 77 additions and 0 deletions
77
doc/charger_test_results.md
Normal file
77
doc/charger_test_results.md
Normal file
|
@ -0,0 +1,77 @@
|
|||
# Test Results on different Real-World Chargers
|
||||
|
||||
## ABB Terra 53 Triple Charger
|
||||
|
||||
Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolstadt/hagebaumarkt-Siemensstrasse-1/48209/
|
||||
|
||||
Test results of version v0.2
|
||||
- [x] SLAC
|
||||
- [x] SDP
|
||||
- [x] TCP connection
|
||||
- [x] EXI
|
||||
- [x] DIN SupportedApplicationProtocol
|
||||
- [x] DIN SessionSetup
|
||||
- [x] DIN ServiceDiscovery
|
||||
- [x] DIN ChargeParameterDiscovery
|
||||
- [ ] DIN CableCheck
|
||||
- [ ] DIN PreCharge
|
||||
- [ ] DIN PowerDelivery, CurrentDemand
|
||||
|
||||
## ABB Terra HPC
|
||||
|
||||
Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/Total-Tankstelle-Ruppertswies-6/63794/
|
||||
|
||||
Test results tbd
|
||||
|
||||
## Alpitronic HPC HYC300
|
||||
|
||||
Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolstadt/Dehner-Garten-Center-Degenhartstrasse-Degenhartstrasse-2/71112/
|
||||
|
||||
Test results of version v0.2
|
||||
- [x] SLAC
|
||||
- [x] SDP
|
||||
- [ ] TCP connection
|
||||
- [ ] EXI
|
||||
- [ ] DIN SupportedApplicationProtocol
|
||||
- [ ] DIN SessionSetup
|
||||
- [ ] DIN ServiceDiscovery
|
||||
- [ ] DIN ChargeParameterDiscovery
|
||||
- [ ] DIN CableCheck
|
||||
- [ ] DIN PreCharge
|
||||
- [ ] DIN PowerDelivery, CurrentDemand
|
||||
|
||||
## Compleo Cito BM 500
|
||||
|
||||
Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/EDEKA-Ingolstaedter-Strasse-114/62619/
|
||||
|
||||
Test results tbd
|
||||
|
||||
## Efacec QC45 Triple Charger
|
||||
|
||||
Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Hepberg/Koeschinger-Forst-West-A9/15982/
|
||||
|
||||
Test results tbd
|
||||
|
||||
## Efacec HPC Efapower Kiosk HV175
|
||||
|
||||
Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Neufahrn-bei-Freising/Fuerholzen-West-A9/22771/
|
||||
|
||||
Test results tbd
|
||||
|
||||
## Ionity Tritium Veefil-PK
|
||||
|
||||
Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Hepberg/IONITY-Koeschinger-Forst-Ost-A9/37875/
|
||||
|
||||
Test results tbd
|
||||
|
||||
## Porsche
|
||||
|
||||
Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolstadt/Audi-Forum-Ettinger-Strasse/7970/
|
||||
|
||||
Test results tbd
|
||||
|
||||
## Tesla Supercharger V3
|
||||
|
||||
Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/Supercharger-Car-Wash-Ruppertswies-4/69557/
|
||||
|
||||
Test results tbd
|
Loading…
Reference in a new issue