# Open issues
## Issue16: First CurrentDemandReq is rejected with FAILED_SequenceError and EVSE_Shutdown
- observed on Alpitronics HPC with version v0.4-6-g257e5af
- log 2022-12-20_alpi_currentDemandSequenceErrorShutdown.pcapng
- same result in two trys
## Issue15: After end of PreCharging, the log says "re-initializing fsmPev"
- observed with v0.4 on the Compleo charger
- PreCharge target voltage is reached. The fsmPev sends a message
01fe800100000012809a022189cbf75b9625a9513022800a0800
and after one second the state machine seems to run into timeout.
## Issue14: Connection loss after authorization
# Closed issues
## [Solved] Issue14: Connection loss after authorization
- with version v0.4.
- same version works fine on Compleo
- could be also caused by weak power of the powerbank. The TpLink and Dieter made restart from time to time.
- to be retested with better supply and on other chargers.
- Test pass with v0.4-6-g257e5af, with the Intenso two-cell powerbank.
## Issue12: Alpi reports "sequence error" for CableCheck
## [Solved] Issue12: Alpi reports "sequence error" for CableCheck
- with version v0.3.
- maybe he expects the state C, or something is wrong with the sequence before.
# Closed issues
- Test pass with v0.4-6-g257e5af
## [Solved] Issue13: Compleo SLAC stops after SlacParamResponse
- Root cause: The Compleo ignores the StartAttenChar, if the timeout field is set to 1000ms instead of the nominal 600ms.

View file

@ -27,7 +27,7 @@ Test results tbd
Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolstadt/Dehner-Garten-Center-Degenhartstrasse-Degenhartstrasse-2/71112/
Test results of version v0.3
Test results of version v0.4-6-g257e5af
- [x] SLAC
- [x] SDP
- [x] TCP connection
@ -35,11 +35,17 @@ Test results of version v0.3
- [x] DIN SupportedApplicationProtocol
- [x] DIN SessionSetup
- [x] DIN ServiceDiscovery
- [x] DIN ChargeParameterDiscovery
- [x] DIN ServicePaymentSelection
- [x] DIN ContractAuthentication
- [ ] DIN CableCheck
- [ ] DIN PreCharge
- [ ] DIN PowerDelivery, CurrentDemand
- [x] DIN ChargeParameterDiscovery
- [x] DIN CableCheck
- [x] DIN PreCharge
- [x] DIN PowerDelivery Start
- [ ] DIN CurrentDemand rejected with FAILED_SequenceError and EVSE_Shutdown. Issue 16
- [ ] DIN PowerDelivery Stop
- [ ] DIN WeldingDetection
- [ ] DIN SessionStop
- [x] Inlet voltage measurement (shows 500V during cable check, and 230V during precharge)
## Compleo Cito BM 500

View file

@ -299,6 +299,12 @@ is not yet implemented.
- PreCharge starts, but terminates before full voltage is reached. Switching the load with power-relay is not yet implemented from
hardware side. Without the load, we see the intended 230V precharge voltage, and run into timeout (to be investigated).
### 2022-12-20 Measurement of inlet voltage works
- Tests ran on Alpitronics HPC.
- Measuring the inlet voltage with Arduino "Dieter" works. During CableCheck and PreCharge, the inlet voltage is shown in the GUI.
- The Alpi confirms the PowerDelivery (start), but rejects the CurrentDemandRequest with FAILED_SequenceError and EVSE_Shutdown.
- Results (log file and pcap) are stored in https://github.com/uhi22/pyPLC/tree/master/results.
### Test results on real-world chargers
See [charger_test_results.md](doc/charger_test_results.md)