pyPLC/doc/charger_test_results.md
2022-12-20 12:43:06 +01:00

2.9 KiB

Test Results on different Real-World Chargers

ABB Terra 53 Triple Charger

Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolstadt/hagebaumarkt-Siemensstrasse-1/48209/

Test results of version v0.2

  • SLAC
  • SDP
  • TCP connection
  • EXI
    • DIN SupportedApplicationProtocol
    • DIN SessionSetup
    • DIN ServiceDiscovery
    • DIN ChargeParameterDiscovery
    • DIN CableCheck
    • DIN PreCharge
    • DIN PowerDelivery, CurrentDemand

ABB Terra HPC

Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/Total-Tankstelle-Ruppertswies-6/63794/

Test results tbd

Alpitronic HPC HYC300

Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolstadt/Dehner-Garten-Center-Degenhartstrasse-Degenhartstrasse-2/71112/

Test results of version v0.4-6-g257e5af

  • SLAC
  • SDP
  • TCP connection
  • EXI
    • DIN SupportedApplicationProtocol
    • DIN SessionSetup
    • DIN ServiceDiscovery
    • DIN ServicePaymentSelection
    • DIN ContractAuthentication
    • DIN ChargeParameterDiscovery
    • DIN CableCheck
    • DIN PreCharge
    • DIN PowerDelivery Start
    • DIN CurrentDemand rejected with FAILED_SequenceError and EVSE_Shutdown. Issue 16
    • DIN PowerDelivery Stop
    • DIN WeldingDetection
    • DIN SessionStop
  • Inlet voltage measurement (shows 500V during cable check, and 230V during precharge)

Compleo Cito BM 500

Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/EDEKA-Ingolstaedter-Strasse-114/62619/

Test results of version v0.4

  • SLAC
  • SDP
  • TCP connection
  • EXI
    • DIN SupportedApplicationProtocol
    • DIN SessionSetup
    • DIN ServiceDiscovery
    • DIN ServicePaymentSelection
    • DIN ContractAuthentication
    • DIN ChargeParameterDiscovery
    • DIN CableCheck (10s loop ongoing, then finished OK)
    • DIN PreCharge ok, but at the end the state machine runs into timeout. Issue 15.
    • DIN PowerDelivery, CurrentDemand

Efacec QC45 Triple Charger

Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Hepberg/Koeschinger-Forst-West-A9/15982/

Test results tbd

Efacec HPC Efapower Kiosk HV175

Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Neufahrn-bei-Freising/Fuerholzen-West-A9/22771/

Test results tbd

Ionity Tritium Veefil-PK

Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Hepberg/IONITY-Koeschinger-Forst-Ost-A9/37875/

Test results tbd

Porsche

Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolstadt/Audi-Forum-Ettinger-Strasse/7970/

Test results tbd

Tesla Supercharger V3

Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/Supercharger-Car-Wash-Ruppertswies-4/69557/

Test results

  • SLAC: fails. It sends SLAC_PARAM_CNF, but nothing more.