2.6 KiB
Test Results on different Real-World Chargers
ABB Terra 53 Triple Charger
Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolstadt/hagebaumarkt-Siemensstrasse-1/48209/
Test results of version v0.2
- SLAC
- SDP
- TCP connection
- EXI
- DIN SupportedApplicationProtocol
- DIN SessionSetup
- DIN ServiceDiscovery
- DIN ChargeParameterDiscovery
- DIN CableCheck
- DIN PreCharge
- DIN PowerDelivery, CurrentDemand
ABB Terra HPC
Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/Total-Tankstelle-Ruppertswies-6/63794/
Test results tbd
Alpitronic HPC HYC300
Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolstadt/Dehner-Garten-Center-Degenhartstrasse-Degenhartstrasse-2/71112/
Test results of version v0.3
- SLAC
- SDP
- TCP connection
- EXI
- DIN SupportedApplicationProtocol
- DIN SessionSetup
- DIN ServiceDiscovery
- DIN ChargeParameterDiscovery
- DIN ContractAuthentication
- DIN CableCheck
- DIN PreCharge
- DIN PowerDelivery, CurrentDemand
Compleo Cito BM 500
Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/EDEKA-Ingolstaedter-Strasse-114/62619/
Test results of version v0.4
- SLAC
- SDP
- TCP connection
- EXI
- DIN SupportedApplicationProtocol
- DIN SessionSetup
- DIN ServiceDiscovery
- DIN ServicePaymentSelection
- DIN ContractAuthentication
- DIN ChargeParameterDiscovery
- DIN CableCheck (10s loop ongoing, then finished OK)
- DIN PreCharge ok, but at the end the state machine runs into timeout. Issue 15.
- DIN PowerDelivery, CurrentDemand
Efacec QC45 Triple Charger
Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Hepberg/Koeschinger-Forst-West-A9/15982/
Test results tbd
Efacec HPC Efapower Kiosk HV175
Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Neufahrn-bei-Freising/Fuerholzen-West-A9/22771/
Test results tbd
Ionity Tritium Veefil-PK
Test site: e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Hepberg/IONITY-Koeschinger-Forst-Ost-A9/37875/
Test results tbd
Porsche
Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Ingolstadt/Audi-Forum-Ettinger-Strasse/7970/
Test results tbd
Tesla Supercharger V3
Test site e.g. https://www.goingelectric.de/stromtankstellen/Deutschland/Koesching/Supercharger-Car-Wash-Ruppertswies-4/69557/
Test results
- SLAC: fails. It sends SLAC_PARAM_CNF, but nothing more.