Issue17: Welding detection fails

  • WeldingDetectionRes says "failed" on alpitronics, and no response on ABBHPC and ABBTriple
  • version v0.4-7-g7cea8b5 (2022-12-21)

Issue21: Missing fields in ChargeParameterDiscoveryReq

Issue18: On SuperCharger we ignore the session ID

  • In the SessionSetupResponse, the SuperCharger V3 correctly provides a sessionID, e.g. "06ef0071".
  • But we ignore this, and send in all next messages (starting with ServiceDiscoveryReq) the sessionID "deadbeefdeadbeef".
  • The SuperCharger correctly complains with "ResponseCode": "FAILED_UnknownSession".
  • logs 2023-03-02_SuperCharger_CableCheck_error.pcapng and 2023-03-02_SuperCharger_CableCheck_error.decoded.txt
  • observed with Software version v0.5-12-g23b1384, on 2023-03-02.
  • root cause: In main_commandlineinterface.c we check, whether the session ID has 16 characters, to represent 8 hex bytes. But the SuperCharger provides 8 characters, to represent 4 bytes. That's why the function useSessionIdFromCommandLine() operates with the default session ID "deadbeefdeadbeef".
  • solution: in function useSessionIdFromCommandLine(), also accept shorter session IDs. And in function init_dinMessageHeaderWithSessionID(), use a dynamic length instead of the fixed length LEN_OF_SESSION_ID (=8).
  • implementation done with 9c08c19ce1

[Solved] Issue20: Missing EVCCID in the SessionSetupReq

Issue19: Wrong determination of MAC and IPv6

  • SOLVED in v0.7 (2023-04-19)
  • On linux, the deprecated ifconfig is not a good choice. And, if multiple interfaces are present, the wrong address is fetched.
  • Solution: Three parts
  1. Use "ip addr" instead of "ifconfig" -> done
  2. Filter for the correct interface -> done
  3. Make the interface name configurable -> done

Issue15: After end of PreCharging, the log says "re-initializing fsmPev"

  • SOLVED
  • observed with v0.4 on the Compleo charger
  • PreCharge target voltage is reached. The fsmPev sends a message 01fe800100000012809a022189cbf75b9625a9513022800a0800 and after one second the state machine seems to run into timeout.
  • same timeout issue observed on Compleo by johu with version 0.6+
  • with v0.7 (2023-04-19) tested ok, see results/2023-04-19_compleo_pyPlc_lightbulb_failedBadRegulation.pcapng

[Solved] Issue16: First CurrentDemandReq is rejected with FAILED_SequenceError and EVSE_Shutdown

  • observed on Alpitronics HPC with version v0.4-6-g257e5af
  • log 2022-12-20_alpi_currentDemandSequenceErrorShutdown.pcapng
  • same result in two trys
  • root cause: In the exi encoder, the PowerDeliveryReq.ReadyToChargeState was treated as enum as in the ISO, but in fact it must be boolean.
  • Fixed with a00f1fba87
  • Test pass 2022-12-21 with v0.4-7-g7cea8b5 on alpi, ABB HPC and ABB triple charger.

[Solved] Issue14: Connection loss after authorization

  • with version v0.4.
  • same version works fine on Compleo
  • could be also caused by weak power of the powerbank. The TpLink and Dieter made restart from time to time.
  • to be retested with better supply and on other chargers.
  • Test pass with v0.4-6-g257e5af, with the Intenso two-cell powerbank.

[Solved] Issue12: Alpi reports "sequence error" for CableCheck

  • with version v0.3.
  • maybe he expects the state C, or something is wrong with the sequence before.
  • Test pass with v0.4-6-g257e5af

[Solved] Issue13: Compleo SLAC stops after SlacParamResponse

  • Root cause: The Compleo ignores the StartAttenChar, if the timeout field is set to 1000ms instead of the nominal 600ms.
  • Solution: implemented the nominal 600ms.
  • fixed with commit cf9160c1bc
  • Test pass on Compleo with v0.4

[Solved] Issue10: Alpi says SequenceError in ChargeParameterDiscoveryRes

  • ServicePaymentSelectionRes says "ResponseCode": "OK", and has no more fields.
  • Afterwards we send ChargeParameterDiscoveryReq and get ChargeParameterDiscoveryRes containing "ResponseCode": "FAILED_SequenceError".
  • Analysis: In the ISO case, the ChargeParameterDiscoveryReq comes after the AuthorizationRes with EVSEProcessing=Finished. But we are using DIN, and here there is no AuthorizationRes, but ContractAuthentication instead. But, this does not have a field EVSEProcessing. And in DIN, we have dinContractAuthenticationResType, which contains ResponseCode and EVSEProcessing (see OpenV2G, dinEXIDatatypes.h).
  • Solution: Send ContractAuthenticationReq after ServicePaymentSelectionRes, and repeat it until it says "finished". Test pass with v0.3.

[Solved] Issue11: TCP connection fails on Alpi

  • Observation: On Alpitronics, the SDP works, but the TCP connect fails. The connection is rejected by the charger.
  • Root cause: We used fixed port 15118 for the TCP. This is not intended, even it works on other chargers (ABB).
  • Solution: use the TCP port, which was announced in the SDP response.
  • Test pass with version v0.2-9-ga9b6e82.